MP Filtri HPB150 Installation, Service & Maintenance Manual

High pressure filters, bowl kit

Advertisement

Quick Links

T
PASSION
PERFORM
HIGH
PRESSURE
FILTERS
INSTALLATION,
SERVICE AND
MAINTENANCE
MANUAL
AND SAFETY
INSTRUCTIONS
INSTRUCTIONS
HPB150
HPB150
BOWL KIT
BOWL KIT
EN
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPB150 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MP Filtri HPB150

  • Page 1 HIGH PRESSURE FILTERS INSTALLATION, SERVICE AND MAINTENANCE MANUAL AND SAFETY INSTRUCTIONS INSTRUCTIONS HPB150 HPB150 BOWL KIT BOWL KIT PASSION PERFORM...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page Description General warnings Tools Handling Dimensional drawings Installation Commissioning Standard maintenance Filter element replacement Special maintenance Seals replacement Instructions for use in explosive atmospheres Regulations Spare parts list Ordering code 13.1 Bowl assembly 13.2 Filter element Troubleshooting 14.1 Misuse of the product...
  • Page 4: Description

    - Connect the filter with an anti-loosening system and regularly check the condition of the connection - The declared performances and the safety of the product are only guaranteed when MP Filtri original spare parts are used - Warranty is only effective if MP Filtri original spare parts are used.
  • Page 5: Handling

    HPB150 Handling - The unit is shipped in a cardboard box with dimensions depending on the order - The handling must be carried out in accordance with the laws in force in the country of use of the product - Handle the product with care, avoid impacts - Store in a dry and frost-free room - The unit should be stored in a suitable location away from the production area when not in use.
  • Page 6: Dimensional Drawings

    Dimensional drawings HPB150 Filter length [mm] Ø25 Ø31 Ø80 Ø86 M85x1.5 O-Ring seal Anti-extrusion ring Recommended clearance space for maintenance High Pressure filters...
  • Page 7: Installation

    HPB150 Installation O-Ring seal Anti-extrusion ring - Check that the system working pressure does not exceed the maximum working pressure of the filter. - Check that the filter is compatible with the fluid used in the system - Remove the plastic plugs from the inlet, the outlet and the indicator connection...
  • Page 8: Standard Maintenance

    Standard maintenance FILTER ELEMENT REPLACEMENT - Check the availability of the right spare filter element by comparing the part number shown on the element with that shown on the spare parts list. - For the disassembly and the assembly of the parts, please refer to the tools table in paragraph 3 - Switch off the system - (Fig.
  • Page 9: Special Maintenance

    HPB150 Special maintenance SEALS REPLACEMENT - Check the availability of the right spare parts by comparing the part numbers shown on them with that shown on the filter name plate or spare parts list - For the disassembly and the assembly of the parts, please refer to the tools table in paragraph 3 - Switch off the system - (Fig.
  • Page 10: Instructions For Use In Explosive Atmospheres

    MP FILTRI has carried out a voluntary certification of a part of the product range in compliance with directive 2014/34/EU, in order to guarantee an appropriate degree of safety in these particular conditions.
  • Page 11: Spare Parts List

    HPB150 12. Spare parts list Item Quantity Description Designation / Ordering code Complete filter See “Ordering Code” table Filter element EPDM Seals kit 02050816 02050826 02050836 Filter element seal O-Ring 4125 - di = 31.34 - d = 3.53 Bowl seal O-Ring 3287 - di = 72.69 - d...
  • Page 12: Ordering Code

    Filtration rating (filter media) Inorganic microfiber 3 µm Inorganic microfiber 6 µm Inorganic microfiber 10 µm Inorganic microfiber 16 µm Inorganic microfiber 25 µm Wire mesh 25 µm Element ∆p 20 bar Execution MP Filtri standard Customized High Pressure filters...
  • Page 13: Filter Element

    Filtration rating (filter media) Inorganic microfiber 3 µm Inorganic microfiber 6 µm Inorganic microfiber 10 µm 16 µm Inorganic microfiber Inorganic microfiber 25 µm M25 Wire mesh 25 µm Seals EPDM Element ∆p 20 bar Execution MP Filtri standard Customized High Pressure filters...
  • Page 14: Troubleshooting

    14. Troubleshooting 14.1 MISUSE OF THE PRODUCT This product should be connected to a hydraulic line; this must not exceed upper pressure limit of the product. his product should follow all standard operating procedures previously set at the operating location as well as the procedures required by the manufacturer.
  • Page 15 NOTES High Pressure filters...
  • Page 16 NOTES High Pressure filters...
  • Page 17 All data, details and words contained in this publication are provided for use by technically qualifi ed personnel at their discretion, without warranty of any kind. MP Filtri reserves the right to make modifi cations to the models and versions of the described products at any time for both technical and/or commercial reasons.
  • Page 18 WORLDWIDE NETWORK CANADA CHINA FRANCE GERMANY INDIA SINGAPORE UNITED ARAB EMIRATES UNITED KINGDOM ITALY PASSION PERFORM mp ltri.com Scan or click me!

Table of Contents