Download Print this page

Advertisement

Quick Links

Low & Medium Pressure fi lters
LMD 951 series
Maximum working pressure up to 1.6 MPa (16 bar) - Flow rate up to 1200 l/min
441
Low & Medium Pressure fi lters

Advertisement

loading
Need help?

Need help?

Do you have a question about the LMD 951 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MP Filtri LMD 951 Series

  • Page 1 Low & Medium Pressure fi lters LMD 951 series Maximum working pressure up to 1.6 MPa (16 bar) - Flow rate up to 1200 l/min Low & Medium Pressure fi lters...
  • Page 2 TYPICAL FILTER SIZING Selection Software Step Select “FILTER SIZING SOFTWARE” after login Select “FILTER SIZING” after login from a product page Choose the type of fi lter family. Step Enter the main data for sizing the fi lter Enter the main data for sizing the fi lter then push CALCULATE.
  • Page 3: Manual Edit

    TYPICAL FILTER SIZING Step Choose the most suitable fi lter from the proposed list. Step It is possible to change the fi lter SAVE YOUR FILTER’S REPORT MANUAL EDIT modifying every parameter. SAVE IN YOUR ARCHIVE typing your reference data and then SAVE AS PDF A new browser window displays the pdf...
  • Page 4: General Information

    LMD 951 GENERAL INFORMATION Description Technical data Low & Medium Pressure filters Filter housing materials - Head: Anodized Aluminium Duplex - Housing: Anodized Aluminium Maximum working pressure up to 1.6 MPa (16 bar) - Manifolds: Welded - Painted black Flow rate up to 1200 l/min - Bypass valve: Steel - 3-way ball valve: Steel body - Stainless steel ball LMD950 is a range of versatile low pressure duplex filter with integrated...
  • Page 5 LMD 951 GENERAL INFORMATION FILTER ASSEMBLY SIZING Flow rates [l/min ] Filter element design - N Series Filter series Length LMD 951 1066 1096 1233 Maximum flow rate for a complete low and medium pressure filter with a pressure drop ∆p = 0.7 bar.
  • Page 6 Wire mesh 90 µm Inorganic microfiber 16 µm Inorganic microfiber 25 µm Element ∆p Execution 20 bar MP Filtri standard WA025 Water absorber inorganic microfiber 25 µm With internal tube for low flow rate Customized FILTER ELEMENT CU950 Configuration example:...
  • Page 7 LMD 951 Dimensions Recommended clearance space for maintenance Breather plug Connection for differential indicator T2 plug Drain plug Connections Connections Fixing holes Ø 15 Nr. 4 holes LMD951 Connections [mm] [mm] [mm] [mm] 1530 1530 1577 1577 1530 1530 1577 1577 Low &...
  • Page 8: Spare Parts

    LMD 951 SPARE PARTS Order number for spare parts LMD 951 Item 7: for complete fi lter code and spare parts, see LMP 950 - 951 series chapter Quantity: - fi lter spare parts: 2 pcs. - fi lter seal kit: 2 pcs. Q.ty: 1 pc.
  • Page 9 LMD 951 Low & Medium Pressure filters...
  • Page 10 Clogging indicators Introduction Filter elements are efficient only if their Dirt Holding Capacity is fully exploited. MP Filtri can supply indicators of the following designs: This is achieved by using filter housings equipped with clogging indicators. - Vacuum switches and gauges...
  • Page 11 DIFFERENTIAL INDICATORS Dimensions DEA*50 Hydraulic symbol Materials - Body: Brass Electrical Differential Indicator - Base: Black polyamide - Contacts: Silver Settings Ordering code 2.0 bar ±10% DE A 20 x A 50 P01 - Seal: HNBR - FPM 5.0 bar ±10% DE A 50 x A 50 P01 Technical data - Max working pressure: 420 bar...
  • Page 12 DIFFERENTIAL INDICATORS Dimensions DEM*30 Hydraulic symbol Materials - Body: Brass Electrical Differential Indicator - Base: Black polyamide - Contacts: Silver Settings Ordering code 2.0 bar ±10% DE M 20 x x 30 P01 - Seal: HNBR - FPM 5.0 bar ±10% DE M 50 x x 30 P01 Technical data - Max working pressure: 420 bar...
  • Page 13 DIFFERENTIAL INDICATORS Dimensions DES*30 Hydraulic symbol Materials - Body: Brass Electrical Differential Indicator - Internal parts: Brass - Polyamide - Contacts: Silver Settings Ordering code - Seal: HNBR 2.5 bar ±10% DE S 25 H A 30 P01 4.0 bar ±10% DE S 40 H A 30 P01 Technical data - Max working pressure: 16 bar...
  • Page 14 DIFFERENTIAL INDICATORS Dimensions DLA*71 Hydraulic symbol Materials - Body: Brass Electrical/Visual Differential Indicator - Base: Black polyamide - Contacts: Silver Settings Ordering code 2.0 bar ±10% DL A 20 x A 71 P01 - Seal: HNBR - FPM 5.0 bar ±10% DL A 50 x A 71 P01 Technical data - Max working pressure: 420 bar...
  • Page 15 DIFFERENTIAL INDICATORS Dimensions DTA*70 Hydraulic symbol Materials - Body: Brass Electronic Differential Indicator - Internal parts: Brass - Polyamide Industry 4.0 - Contacts: Silver Settings Ordering code READY 2.0 bar ±10% DT A 20 x x 70 P01 - Seal: HNBR - FPM 5.0 bar ±10% DT A 50 x x 70 P01...
  • Page 16 DIFFERENTIAL INDICATORS Dimensions Hydraulic symbol Materials - Body: Brass Visual Differential Indicator - Internal parts: Brass - Polyamide - Contacts: Silver Settings Ordering code - Seal: HNBR 2.5 bar ±10% DV S 25 H P01 4.0 bar ±10% DV S 40 H P01 Technical data - Reset: Automatic reset...
  • Page 17 Connection EN 175301-803, transparent base with lamps 110 Vdc • Option Connection IEC 61076-2-101 D (M12) • MP Filtri standard Connection IEC 61076-2-101 D (M12), black base with lamps 24 Vdc • Customized DESIGNATION & ORDERING CODE - DIFFERENTIAL INDICATOR PLUG...