TABLE OF CONTENTS Page Description General warnings Tools Handling Dimensional drawings Installation Commissioning Standard maintenance Filter element replacement Special maintenance Clogging indicator (or plug) replacement Seals replacement Instructions for use in explosive atmospheres Regulations Spare parts list Ordering code 13.1 Filter / Housing / Bowl 13.2 Filter element...
- Connect the filter with an anti-loosening system and regularly check the condition of the connection - The declared performances and the safety of the product are only guaranteed when MP Filtri original spare parts are used - Warranty is only effective if MP Filtri original spare parts are used.
FMMX050 Handling - The unit is shipped in a cardboard box with dimensions depending on the order - The handling must be carried out in accordance with the laws in force in the country of use of the product - Handle the product with care, avoid impacts - Store in a dry and frost-free room - The unit should be stored in a suitable location away from the production area when not in use.
FMMX050 Parts identification FMM050 Installation Item Description Clogging indicator connection Identification plate Drain plug Clogging indicator connection Identification plate Drain plug - Check that the system working pressure does not exceed the maximum working pressure of the filter. The maximum working pressure of the filter is shown on the identification plate...
Standard maintenance FILTER ELEMENT REPLACEMENT The clogging indicator monitors the conditions of the filter element. The alarm signal shown by the differential indicator during the normal working conditions (pressure, temperatures …) means that the filter element needs to be replaced. - Check the availability of the right spare filter element by comparing the part number shown on the element with that shown on the filter name plate or spare parts list - For the disassembly and the assembly of the parts, please refer to the tools table in paragraph 3...
SEALS REPLACEMENT - Check the availability of the right spare parts by comparing the part numbers shown on them with that shown on the filter name plate or spare parts list - Switch off the system - For the disassembly and the assembly of the parts, please refer to the tools table in paragraph 3 - (Fig.
MP FILTRI has carried out a voluntary certification of a part of the product range in compliance with directive 2014/34/EU, in order to guarantee an appropriate degree of safety in these particular conditions.
14. Troubleshooting 14.1 MISUSE OF THE PRODUCT This product should be connected to a hydraulic line; this must not exceed upper pressure limit of the product. his product should follow all standard operating procedures previously set at the operating location as well as the procedures required by the manufacturer.
Page 19
All data, details and words contained in this publication are provided for use by technically qualifi ed personnel at their discretion, without warranty of any kind. MP Filtri reserves the right to make modifi cations to the models and versions of the described products at any time for both technical and/or commercial reasons.
Page 20
WORLDWIDE NETWORK CANADA CHINA FRANCE GERMANY INDIA SINGAPORE UNITED ARAB EMIRATES UNITED KINGDOM ITALY PASSION PERFORM mp ltri.com...
Need help?
Do you have a question about the FMMX050 and is the answer not in the manual?
Questions and answers