EXTREME WASHDOWN
PLATFORM SCALE
WARNING! Explosion hazard.
CAUTION! Keep children away from battery.
CAUTION! Do not burn battery.
CAUTION! Corrosion hazard.
• The load placed on the weighing pan must not
exceed the maximum weighing capacity of the
scale.
• Place the scale on a firm, level surface free from
vibrations for accurate weight readings.
• Adjust the four leveling feet (if fitted) to set the scale
pan level.
• Avoid operating the scale in direct sunlight or drafts
of any kind.
• If possible, avoid connecting the scale to AC power
outlet sockets that are adjacent to other appliances
to minimize the possibility of interference affecting
performance of the scale.
• Remove any weight on the weighing pan before the
scale is switched on and avoid leaving weight on
the pan for long periods of time.
• All goods weighed should be placed in the center
of the weighing pan for accurate weighing. The
overall dimensions of the goods being weighed
should not exceed the dimensions of the weighing
pan.
PAGE 1 OF 20
1-800-295-5510
uline.com
SAFETY
• Protect the scale from high temperatures.
• Avoid objects impacting the scale. Do not drop
loads onto the scale or subject the weighing pan
to any strong shock loads.
• Operate or charge the scale in an open area. Do
not squeeze the power cord, which may result in
the wire overheating and catching on fire.
• The battery's electrolyte is caustic and causes
metal, cotton, etc. to corrode.
• Charge battery in a well-ventilated area away from
sparks or open flame.
SETUP
• Once the scale has been powered on, it will go
through an LCD display test. Scale is ready for use
when the display shows zero.
• The scale requires 15-20 minutes to warm up before
operation to ensure best accuracy.
NOTE: When the
the screen, the batteries need to be charged.
BATTERY STORAGE
• Scale uses a fully sealed, maintenance-free battery.
Customer does not need to replenish electrolyte.
• The scale should be recharged every three months
to prevent failure of the internal rechargeable
battery.
• The battery takes 8-10 hours to fully recharge.
• The temperature of battery should not exceed 113°F.
symbol keeps flashing on
0325 IH-11908

Advertisement

loading
Need help?

Need help?

Do you have a question about the H-11908 and is the answer not in the manual?

Questions and answers

Summary of Contents for U-Line H-11908

  • Page 1 H-11908, H-11909 1-800-295-5510 uline.com EXTREME WASHDOWN PLATFORM SCALE SAFETY WARNING! Explosion hazard. • Protect the scale from high temperatures. • Avoid objects impacting the scale. Do not drop loads onto the scale or subject the weighing pan CAUTION! Keep children away from battery.
  • Page 2: Overview Of Controls

    OVERVIEW OF CONTROLS CONTROL PANEL CONTROL PANEL BUTTONS DESCRIPTION ON/OFF Key Key Functions Key Net/Gross Weight Key Unit Key STABLE GROSS HOLD Wireless Zero Key TARE UNIT ZERO GROSS PRINT Charging Tare/PT Key M+/Print Key CONTROL FUNCTIONS BUTTON PRIMARY FUNCTION SECONDARY FUNCTION ON/OFF ------------...
  • Page 3: Lcd Display

    LCD DISPLAY DISPLAY DISPLAY CHARACTERS CHARACTER DISPLAY CHARACTER DISPLAY Upper Limit Stable Indicator Value Between HI and LO Gross Weight Indicator Unit Weight Insufficient Lower Limit Indicator Unit "kilogram" Pre-tare Indicator Unit "pound" (Hold) Weight Hold Indicator Counting Mode Indicator M+ Indicator Zero Point Indicator OZ Unit Indicator...
  • Page 4: Operation

    OPERATION ON/OFF KEY • If there is tare, the pre-tare cannot be done. If there is pre-tare first, and the tare weight is more than Press the ON/OFF key to switch the indicator on or off. pre-tare weight, tare can be done. •...
  • Page 5: Self-Test Mode

    OPERATION CONTINUED SELF-TEST MODE With no load, press TARE/PT key to enter pre-tare setting. When power is off, hold NET/GROSS key and press NOTE: The blinking character on the display ON/OFF key to turn on scale. Wait until display shows 0 1 AdC indicates that it is selected to enter data.
  • Page 6 OPERATION CONTINUED FIRMWARE VERSION DISPLAY MODE ( 03 GEr BACK TO THE LAST SCREEN ( 00 ESC Press TARE/PT key to enter. Display shows the • Press TARE/PT key to exit self-test mode. The scale will 02052 firmware version if software seal is enabled re-power on automatically.
  • Page 7: Configuration Workflow

    CONFIGURATIONS CONFIGURATION WORKFLOW 2. Key in the parameter "00-15". In the weighing mode, press NET/GROSS key and ZERO key at the same time to enter the 0 1 FnC configuration mode. The LCD shows 3. Key in "00" and press TARE/PT key to return to the advanced function setting menu.
  • Page 8: Auto Power-Off Timer Setting

    CONFIGURATIONS CONTINUED 3. Use ZERO or UNIT key to select function "on" or "off". AUTO POWER-OFF FUNCTION = backlight function is on. When the weight on weigh pan is less than 10d or keeps Auto = automatic backlight. idle for the set time, the scale will automatically switch = backlight function is off.
  • Page 9: Noise Filter Settings

    CONFIGURATIONS CONTINUED rEturn 5. Press TARE/PT key. LCD displays the last status. = Return (Cancel the restoration) = Restore the default setting 6. Use ZERO or UNIT key to select to set HI/LO/OK backlight color. The defaults include the following: External weight calibration 2.
  • Page 10: Hold Function Settings

    CONFIGURATIONS CONTINUED 5. Use ZERO or UNIT keys to select 0-9 for digital switch : Hold function disabled and stabilization setting. Default setting = 0. The : "Peak hold" mode larger value becomes stable more quickly. : "Stable hold 1" mode 6.
  • Page 11 CONFIGURATIONS CONTINUED hold 5 hold5 ANIMAL SCALE HOLD 2 ( : "Animal scale hold 2" mode 0.000 • With no load, the display shows " ". After the Press TARE/PT key. LCD displays the last used value. animal or object is on the platter and the weight is stable, the display shows the weight value and hold.
  • Page 12 CONFIGURATIONS CONTINUED AUTO UNIT WEIGHT AVERAGING SETTING 3. Press TARE/PT key. FnC 07 FnC 12 F KEY FUNCTION SETTINGS ( Press TARE/PT key. LCD displays the last used value. Press TARE/PT key. F key function represents "MC" function. Display shows last used value. 2.
  • Page 13: Backlight Color Setting

    CONFIGURATIONS CONTINUED 02 EC EXTERNAL WEIGHT CALIBRATION ( 3. Press TARE/PT key. FnC 14 BACKLIGHT COLOR SETTING ( Press TARE/PT key. The display shows the calibration value. The right digit keeps flashing. Press TARE/PT key. LCD displays the last used value. 2.
  • Page 14: Communication Protocol Settings

    CONFIGURATIONS CONTINUED rS 1 NOTE: The default value is 9,600 bits/second. 3. Select , then press TARE/PT key. 3. Press TARE/PT key. rS 1 : to set built-in RS232 4. Key in "00", then press TARE/PT key to return to previous level.
  • Page 15 CONFIGURATIONS CONTINUED FORMAT 11 : Synchronize with display : Gross weight NOTE: = M+ Transmission 2 : Net weight Ticket No. : Synchronized in simple format Date year/month/day and day/month/year (choose one out of two date formats) : Synchronized Gross weight in simple format Time : Synchronized Net weight in simple format G (Gross)
  • Page 16: Transmission Method

    CONFIGURATIONS CONTINUED r51 04 TRANSMISSION METHOD ( NOTE: The default setting = 4. 3. Press TARE/PT key. Press TARE/PT key. LCD displays the last used value. 2. Use ZERO or UNIT key to select. ZERO BAND SETTING FOR AUTO NOTE: The default setting = r51 06 TRANSMISSION ( : Command mode...
  • Page 17: Output Condition Settings

    CONFIGURATIONS CONTINUED r51 09 WEIGHT BAND SETTING FOR AUTO RS232 6/7 DIGITS SETTING ( r51 07 TRANSMISSION ( Press TARE/PT key. LCD displays the last used value. Press TARE/PT key. LCD displays the last used value. 5 i ll 2. Use ZERO or UNIT key to select. Default = NOTE: rs1 07 must be used with rs1 06.
  • Page 18 CONFIGURATIONS CONTINUED r51 11 Y/M/D PRINT FORMAT ( Press TARE/PT key. LCD displays the last value. Use ZERO or UNIT key to select. Press TARE/PT key. LCD displays the last used value. NOTE: The default setting = 2. NOTE: When rS1 03 = 2, three blank lines are inserted between data.
  • Page 19: Power Supply Selection

    POWER SUPPLY POWER SUPPLY Battery 6 V 4 Ah Rechargeable Battery Power Plugged In 100 V–230 V AC No Backlight 30–35 100% White Backlight Power 130–140 100–110 70–80 55–60 Consumption (mA) Yellow Backlight ------------ ------------ ------------ with 1X350Ω Load Cell Green Backlight ------------ ------------...
  • Page 20: Error Code

    TROUBLESHOOTING ERROR CODES ERROR CODE EXPLANATION The EEPROM is not working correctly. The EEPROM is not set yet, or the circuit on PCB is broken. Zero is higher than the zero range when switching the indicator on. Zero is lower than the zero range when switching the indicator on. A/D value is unstable.