Advantech FWA-5072 User Manual
Advantech FWA-5072 User Manual

Advantech FWA-5072 User Manual

1u network appliance
Table of Contents

Advertisement

Quick Links

User Manual
Revision 1.0
FWA-5072
1U Network Appliance
Copyright
2024
Advantech Co. Ltd. All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FWA-5072 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Advantech FWA-5072

  • Page 1 User Manual Revision 1.0 FWA-5072 1U Network Appliance Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 2 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 3: Table Of Contents

    BIOS Setup Menu ................................ 46 4.2.3 Main Setup Menu................................ 47 4.2.4 Platform Setup Menu .............................. 48 4.2.4.1 SW Button Configuration ............................ 49 4.2.4.2 SW GPIO Configuration ............................50 4.2.5 Hardware Setup Menu ............................50 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 4 ....................................66 ..............................67 OWER UPPLY PECIFICATION ....................................... 69 ENSORS 5.5.1 Sensor List ..................................69 5.5.2 Threshold Based Sensors............................. 74 5.5.2.1 Voltage Sensors ................................ 75 5.5.2.2 Temperature Sensors............................76 5.5.2.3 PSU ....................................78 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 5 Table 5.5-2 Threshold Based Sensor Event Data Format ..................74 Table 5.5-3 Threshold Based Sensor Supported Events ..................75 Table 5.5-4 Voltage Sensor List ............................. 75 Table 5.5-5 Temperature Sensor List .......................... 77 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 6 BIOS Setup Menu ..........................61 Figure 4.3-2 BIOS Setup Menu ..........................62 Figure 4.3-3 BIOS Setup Menu ..........................63 Figure 5.1-1 Connector Location ..........................64 Figure 5.2-1 Serial Console Cable Overview......................66 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 7: How To Use This Manual

    Copyright and Trademarks The documentation and the software included with this product are copyrighted by Advantech Co., Ltd. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd.
  • Page 8: Cautions )

    Caution! Cautions are included to help you avoid damaging hardware or losing data. ATTENTION! Des précautions sont incluses pour vous aider à éviter d'endommager le matériel ou de perdre des données. Note! Notes provide additional information. Remarque! Les notes fournissent des informations supplémentaires. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 9: Product Warranty (2 Years)

    Because of Advantech’s high quality-control standards and rigorous testing, most of our customers never need to use our repair service. If an Advantech product is defective, it will be repaired or replaced at no charge during the warranty period. For out of-warranty repairs, you will be billed according to the cost of replacement materials, service time and freight.
  • Page 10: Product Configuration That This Manualc

    Product Configuration That This Manual Covers Figure 0-1 Product Configuration Revision History Table 0-1 Revision List Date Revision Modifications 2024-02-20 Initial version Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 11: Related Manuals & Quick Start Image

    - Advantech FWA-5072 Linux Platform Software Guide https://www.advantech.com/zh-tw/support/details/manual?id=1-2JRN7YB Please reach out to your Advantech representative if you need to refer to the mentioned document and image. Advantech QuickStart Linux Image Getting Started Guide Quick Start Linux Image...
  • Page 12: Getting Started

    National Electrical Code and NFPA 75. 22. RESTRICTED ACCESS AREA: The equipment should only be installed in a Restricted Access Area. 23. DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech disclaims all Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 13 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 14 CC adaptée à une utilisation à une température de fonctionnement de 0 à 40 degrés C (minimum) avec une sortie nominale de 12 V CC, 45.8A. Si vous avez besoin d'aide supplémentaire, veuillez contacter Advantech pour plus d'informations. 4. Débranchez cet équipement de toute prise secteur avant de le nettoyer. Utilisez un chiffon humide.
  • Page 15: Declaration Of Conformity

    22. ZONE D'ACCES RESTREINTE: L'équipement ne doit être installé que dans une zone d'accès restreint. 23. AVERTISSEMENT: Cet ensemble d'instructions est donné conformément à la CEI 704-1. Advantech décline toute responsabilité quant à l'exactitude des déclarations contenues dans ce document. 2.2 Declaration of Conformity 2.2.1 FCC Class A...
  • Page 16 0.75mm2 或 18 AWG。 13. 请注意设备上的所有警告和注意标语。 14. 如果长时间不使用设备,请将设备与电源插座间的电线断开,避免设备被超目标电压波动损坏 15. 请不要让任何液体流入通风口,以免引起火灾或者电路短路。 16. 请不要自行打开设备。为了确保您的安全,请由经过认证的工程师来打开设备。 17. 如遇下列情况,请由专业人员来维修:  电源线或者插头损坏;  设备内部有液体流入;  设备曾暴露在于于潮湿的环境中使用;  设备无法正常工作,或您无法通过用户手册来使其正常工作;  设备跌落或者损坏;  设备有明显的外观破损。 -40° F 18. 请不要把设备放置在超出我们建议的温度范围的环境,即不要低于-40°C( ) 或高于 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 17: Ce Mark

    Le marquage CE sur ce produit indique qu'il est conforme à la Directive européenne sur la compatibilité électromagnétique 2014/30 / UE, Directive sur la sécurité 2014/35 / UE. Note! The equipment is operated and maintained only by professionals Remarque!L'équipement est exploité et entretenu uniquement par des professionnels Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 18: Unpacking

    2.3 Unpacking The FWA-5072 is packaged within a double carton, collectively referred to as the "box" in the subsequent sections of this document. Upon opening the box, you will discover the FWA-5072 nestled in protective foam, with the accessory box similarly embedded within the foam. Begin by removing the accessory box first, followed by pulling out the top foam.
  • Page 19: Installation And Configuration

    The FWA-5072 provides support for 1x VGA port and 2x USB ports to facilitate the connection of a monitor, keyboard, and mouse. Refer to Figure 2.4-1 for precise information on the location of these connectors.
  • Page 20: Installation Via Serial Console

    If your PC lacks an RS232 port, consider acquiring a USB-to-RS232 cable (Figure 2.4-3). Note that for the two RS232 ends of the cables, one should be male and the other female. The FWA-5072 also supports operation via a serial console port, suitable for situations without a connected monitor.
  • Page 21 For users intending to use PuTTY on a PC running Windows OS, the subsequent section outlines how to configure PuTTY on a Windows platform for connecting to the FWA-5072 serial console. Feel free to skip these steps if you have another preferred method, as other terminal programs can be used similarly.
  • Page 22 Also, verify that the OS can output to the serial console port. If you are using a Linux system, consult the "Common IPMI User Manual (Section 2.3)" for specific instructions. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 23 Figure 2.4-5 PuTTY Session Configuration Select “Serial” for the connection type. Figure 2.4-6 PuTTY Serial Configuration In the keyboard submenu, ensure that "VT100+" is selected for the keypad. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 24 PuTTY Keyboard Settings Click the "Open" button, and a PuTTY terminal screen will be displayed. If you want to save the configuration for future use, click the "Save" button. Figure 2.4-8 PuTTY Keyboard Settings Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 25: Installation Via Ikvm

    2.4.3 Installation via iKVM The FWA-5072 is equipped with an Out-of-band (OOB) BMC that incorporates a Web UI, offering a broad spectrum of configuration options, including iKVM for graphic OS installations. To commence, configure the BMC IP within the BIOS (refer to Section 4.3.1) and then access it using...
  • Page 26: Rackmount Kit Installation

    Rackmount Kit Installation Slide rails installation instructions: 1. Align the holes on the slide rails with the holes on the sides of the FWA-5072. 2. Insert screws through the holes in the slide rails and into the corresponding holes on the appliance.
  • Page 27 Figure 2.4-11 Slide Rails Installation Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 28: Getting Help : Technical Support And 3. Product Specification

    FWA-5072 PSU. Additionally, ensure that the primary circuit and all power distribution are not overloaded. Inrush current and steady state power specifications for the FWA-5072 can be found at the label at the side of the unit.
  • Page 29: Overview

    Generation Intel® Xeon® Scalable Processors are equipped with Intel Quick Assist Technology (QAT Gen 4), enhancing encrypted packet throughput. The FWA-5072 platform features two integrated 1GbE wired networking ports, one dedicated IPMI port, and supports up to eight NMC expansion slots. Storage options encompass two M.2 2280 SSDs and two 2.5”...
  • Page 30 The FWA-5072 features a variety of status LEDs on the front panel of the system. Figure 3.2-3 Front LEDs Table 3.2-2 Status LEDs No. or Icon Software LED Color Description Name Controllable (Up to Down) SW_DEF led Green/Amber Solid On...
  • Page 31: System Memory

    3.2.2 System Memory The FWA-5072 supports a total of 16 DDR5 DIMMs. Each processor socket accommodates one DIMM socket per DDR5 channel, and a total of 8 DDR5 channels are supported by each processor socket. The system supports up to 64GB of DDR5 RDIMM per socket, allowing for a total capacity of up to 1TB (4800/5600 MHz).
  • Page 32 5. Place your thumbs near the right and left ends of the DIMM and evenly press down until the white latches fully close with a click. Figure 3.2-9 Seating the DIMM in the Socket 6. If you intent to install additional DIMMs, repeat steps 1 to 5 accordingly. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 33: Cpu Installation Procedures

    3.2.4 CPU Installation Procedures The FWA-5072 supports dual Xeon Scalable processors. This section provides the necessary information for planning the installation of CPUs. Step 1: Assemble processor and carrier together. Ensure processor carrier codes are matched. (e.g. E1A/E1B/E1C code marking on processor and carrier) Step 2: If there is TIM (Thermal Interface Material) protective film on the base of heatsink, remove it.
  • Page 34 Step 5: Ensure that all four anti-tilt wires are in the unlocked positions on the heatsink. Step 6: Align pin 1 indicators on processor/carrier to bolster plate and verify PHM (Processor Heatsink Module) is sitting horizontally over bolster plate assembly. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 35: Ssd Installation Procedures

    Step 8: Tighten all nuts on heatsink using a torque driver with a T30 bit to 8 in-lbf ± 10%. Diagonal tightening sequence is recommended. 3.2.5 2.5” SSD Installation Procedures FWA-5072 supports two internal 2.5” SATA SSD. Step1: Remove middle bar Copyright 2024 Advantech Co.
  • Page 36 Step2: Remove HDD brackets from MB. Step 3: Align screw holes on the bracket, and secure with 4 screws. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 37 Step 4: Insert SATA cables and power cables. Step 4: Install SSD with bracket into the system. Step 5: Plug the SATA cable and SATA power cable Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 38: Ssd Installation Procedures

    3.2.6 M.2 SSD Installation Procedures The FWA-5072 supports two M.2 2280 SATA and NVMe SSDs. Both M.2 slots are accessible on the management board. Step 1: Open the top cover, remove the 2.5” storage cage, and identify the locations of the M.2 slots on the management board.
  • Page 39: Product Version/Ordering Information

    3.3 Product Version/Ordering Information The FWA-5072 is offered in the following standard configurations. Table 3.3-1 Available Product Version Model Name Configurations Peripherals Power Supply Unit -16 x DDR5 sockets -1U form factor - 2 x 2.5 internal -Single socket for 4...
  • Page 40 Table 3.4-1 Datasheet Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 41: Processor(S)

    3.4.1 Processor(s) The FWA-5072 supports dual 4 Gen Intel Xeon Scalable processors. The table below provides an overview of the processor SKUs suitable for this network appliance. Table 3.4-2 Processors Supported List (4 & 5 Gen) Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 42: Spi Tpm 2.0

    Regular BIOS output as well as the setup menu are displayed via console port and please note that the FWA-5072 does not have any on-board POST Code LEDs. A special POST code adapter is required to retrieve BIOS error codes.
  • Page 43: Power Supply Unit(S)

    Additionally, appendix 5.5 offers the FWA-5072 sensor list and information on Threshold-based sensors. 3.4.6 Power Supply Unit(s) The FWA-5072 supports 550W 1+1 redundant PSU. Power-rating and technical specifications for the power supply can be found in Appendix 5.4. Figure 3.4-1...
  • Page 44: Advanced Platform Features

    3.5 Advanced Platform Features The FWA-5072 supports intrusion detection by default. Removing or lifting the top cover will trigger an intrusion detection event. The BMC event will remain active even if the top cover is reinstalled. Please login in to the OS to run the following command:...
  • Page 45: Configuration And Service

    4.2 BIOS Setup Menu 4.2.1 BIOS Defaults The BIOS comes with a set of configuration parameters when shipped by Advantech referred to as “Optimized Defaults” or “factory defaults”. Users have the ability to modify BIOS settings via the setup menu either temporarily or permanently by saving the changes as “User defaults”.
  • Page 46: Bios Setup Menu

    4.2.2 BIOS Setup Menu This section provides information on the FWA-5072’s UEFI BIOS based on AMI’s APTIO BIOS. Users can adjust BIOS settings and manage the special features of the FWA-5072 using the BIOS setup menu. It's important to note that Advantech supports shipping the FWA-5072 with custom BIOS defaults to simplify the deployment and integration for our customers.
  • Page 47: Main Setup Menu

    Figure 4.2-2 BIOS Setup Screen Organization 4.2.3 Main Setup Menu Please refer to the “Common BIOS User Manual” for further guidance. https://www.advantech.com/zh-tw/support/details/manual?id=1-2F8TKW5 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 48: Platform Setup Menu

    4.2.4 Platform Setup Menu Here, only "SW Button Configuration" and "SW GPIO Configuration" are described. For additional information, please refer to the "Common BIOS User Manual." Figure 4.2-3 Platform Setup Main Screen Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 49: Sw Button Configuration

    Table 4.2-1 Platform Setup: SW Button Configuration Menu Items Setup item Access / Options Description Sleep Button / Set the SW Button as Sleep Button or Driver mode SW Button Mode Driver / or disable it. Disabled Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 50: Sw Gpio Configuration

    Similarly, the terms “South Bridge” and “North Bridge” are legacy terms and do not represent the silicon implementation anymore. However, these terms are maintained for consistency with previous products to facilitate easier navigation for users. The submenus are described on the following pages. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 51 Figure 4.2-6 Hardware Configuration Menu Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 52: Hardware Setup: Cpu Configuration

    Socket0 CPU Displays information on the Display only information processor installed Intel VT-x Technology L1 code Cache L2 Cache L3 Cache Enable Hyper- Enables Hyper Threading Hardware Threading Disable (Software Method to Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 53: Hardware Setup: North Bridge Configuration

    DCU IP prefetcher is an L1 data Prefetcher Disable cache prefetcher (MSR 1A4h [3]). 4.2.5.2 Hardware Setup: North Bridge Configuration This menu facilitates the configuration of the memory controller and related features of the processors. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 54 Mode will disable XPT Prefetch." Enable Disable Select to enable / disable Patrol Patrol Scrub Scrub Support Enable at End of POST Data Enable Select to auto to enable the Scrambling for Scrambler Disable DDR4/5 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 55: Hardware Setup: South Bridge Configuration

    Access / Options Description SATA Select sub-menu. Configuration ACPI Settings Select sub-menu. Runtime Error Hardware Select sub-menu. Logging Power on PCH state after Select S0/S5 for ACPI state after a Power Off Last State Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 56 Designates this port as Hot Pluggable Disabled Enabled SATA Hot Plug #Port 3 Designates this port as Hot Pluggable Disabled Enabled SATA Hot Plug #Port 4 Designates this port as Hot Pluggable Disabled Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 57 Designates this port as Hot Pluggable Disabled Enabled SATA Hot Plug #Port 3 Designates this port as Hot Pluggable Disabled Enabled SATA Hot Plug #Port 4 Designates this port as Hot Pluggable Disabled Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 58: Acpi Setting

    Table 4.2-7 Hardware Setup: ACPI Configuration Menu Items Group Setup item Access / Options Description Enable ACPI Enabled Enable or disable BIOS ACPI auto Auto configuration Disabled Configuration None Enabled Enable Enable/disable system ability to Hibernation Hibernate. Disabled Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 59: Runtime Error Logging

    4.2.7 Setup POST & Boot Menu Users can configure the system boot priority settings via the boot page. Please reference “Common BIOS User Manual”. (Note: FWA-5072 supports UEFI mode only; there is no legacy mode. CSM is not supported in FWA-5072 series)
  • Page 60: Security Setup

    Allows users to configure the system password. Please refer to the “Common BIOS User Manual”. 4.2.9 Save & Exit Menu Allows users to save BIOS configuration results and exit. Please refer to the “Common BIOS User Manual”. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 61: Firmware Upgrades

    4.3 Firmware Upgrades The FWA-5072 is equipped with BMC (Baseboard Management Controller) functionality. Firmware upgrades can be performed through BMC. First, you need to set the BMC IP address. The firmware can be upgraded using either the BMC Web interface or the ipmitool utility. Here are the instructions: 4.3.1 How to Access The BMC Web (Node Explorer)?
  • Page 62 2. Choose "BMC network configuration". Figure 4.3-2 BIOS Setup Menu 3. Set "Configuration Address" to "Static", and then enter the IP address, subnet mask, gateway and other relevant network information. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 63: How To Upgrade The Firmware Via Bmc Web (Node Explorer)

    For more details, please refer to the “Common IPMI User Manual (Section 3)”. https://www.advantech.com/zh-tw/support/details/manual?id=1-2FZXUHT 4.4 DIMMs Population With regard to memory insertion order, please refer to Section 3.2.3 for better efficiency and performance. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 64: Appendix

    Connector Name Function WAFER BOX 2x2P for CPU Hot-plug SMBUS CN2~CN17 DDR5 RDIMM Socket CN18~CN21 PCIe x8 Straddle Connector for Advantech NMC slots CN22~CN25 MCIO 8x Connector for NAMB-6072CR CN26~CN27 GenZ 4C connector for PCIe Riser CN28 Wafer Box 2x2P for PCH SGPIO Connector...
  • Page 65 #1~3 CN61 Wafer Box 2x5P 2.0mm Connector for Fan Module LED Indicator CN64~CN65 Wafer Box 2x7P 2.0mm Connector for Fan Module #4,5 CN68 Wafer 6x2P 2.0mm Connector for SPI TPM (PCA- TPMSPI) Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 66: Serial Console Cable Pin Configuration

    Serial Console Cable Overview Table 5.2-1 Serial Console Cable Pin Assignment Connector X1 (DB9) X2(RJ45) Pin assignment 5.3 BIOS Post Code Please refer to the BIOS POST Codes Table in the document linked below: https://www.advantech.com/zh-tw/support/details/manual?id=1-2F8TKW5 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 67: Power Supply Specification

    5.4 Power Supply Specification The FWA-5072 is available with a redundant power supply solution. The specifications for the available power supply on the standard product SKU are listed below. Please consult your Advantech representative if you have further questions. Table 5.4-1 550W AC Power Supply Specification...
  • Page 68 GB 9254 2008 (EMC) Certification (China) GB 17625.1 – (Harmonics) CNCA Certification (China) Input brown out Input surge Input transient Protection Output over voltage Output over current & short circuit Thermal Fan failure Copyright 2023 Advantech Co. Ltd. All rights reserved.
  • Page 69: Sensors

    DIMM module presence sensor C0_DIMM_A2_PRS DIMM module presence sensor C0_DIMM_B1_PRS DIMM module presence sensor C0_DIMM_B2_PRS DIMM module presence sensor C0_DIMM_C1_PRS DIMM module presence sensor C0_DIMM_C2_PRS DIMM module presence sensor C0_DIMM_D1_PRS DIMM module presence sensor Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 70 BIOS POST Code OEM sensor BOARD-POWER Board Power Consumption sensor CONFIG_MODE BMC Configuration Mode OEM sensor PAY_12-VOL Payload Power voltage 12V SB_12-VOL Standby Power voltage 12V PAY_5-VOL Payload Power voltage 5V SB_5-VOL Standby Power voltage 5V Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 71 DIMM Module A2 Temperature C0_DIMM_B1- DIMM Module B1 Temperature C0_DIMM_B2- DIMM Module B2 Temperature C0_DIMM_C1- DIMM Module C1 Temperature C0_DIMM_C2- DIMM Module C2 Temperature C0_DIMM_D1- DIMM Module D1 Temperature C0_DIMM_D2- DIMM Module D2 Temperature Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 72 NMC FRU Device Locator 4 RISER1_PRSNT IPMI Entity Presence sensor RISER1-TMP Riser card temperature sensor RIS1_PCIE1_PRSNT IPMI Entity Presence sensor FAN_MOD1_PRSN Fan (Module) 1 presence sensor FAN_MOD1_1- Fan Module1_1 fan speed sensor SPEED Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 73 PSU FRU Device Locator 9 PSU1_IN-POWER PSU1 input power sensor PSU1_OUT- PSU1 output power sensor POWER PSU1_IN-CUR PSU1 input current sensor PSU1_OUT-CUR PSU1 output current sensor PSU1_IN-VOL PSU1 input voltage sensor PSU1_OUT-VOL PSU1 output voltage sensor Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 74: Threshold Based Sensors

    [5:4] = 01b (Trigger threshold in byte 3), [3:0] = Offset (threshold event) All specified thresholds will generate events (assertion and de-assertion event direction). Unused thresholds have the event generation disabled (event mask bits in SDR data not set). Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 75: Voltage Sensors

    All sensors use a hysteresis for event generation. For all sensors, the hysteresis is 1.5% of the nominal sensor voltage plus ripple from the voltage regulator. Table 5.5-4 Voltage Sensor List Sensor Name Nominal LNR PAY_12-VOL 12.0 11.165 12.474 SB_12-VOL 12.0 10.703 12.474 PAY_5-VOL 4.714 5.246 Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 76: Temperature Sensors

    5.5.2.2 Temperature Sensors Several temperature sensors are supported, either via board-populated IC’s (e.g. TMP75) or Intel PECI readings from the CPU. All temperature sensors use a hysteresis of about 3°C for the event generation. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 77 The same mechanism is implemented for “0xFF” and “0x00” temperature value readings. Table 5.5-5 Temperature Sensor List Sensor Name Nominal INLET-TMP OUTLET-TMP CPU-TMP PCH-TMP C0_DIMM_A1-TMP C0_DIMM_A2-TMP C0_DIMM_B1-TMP C0_DIMM_B2-TMP C0_DIMM_C1-TMP C0_DIMM_C2-TMP C0_DIMM_D1-TMP C0_DIMM_D2-TMP C0_DIMM_E1-TMP C0_DIMM_E2-TMP C0_DIMM_F1-TMP C0_DIMM_F2-TMP C0_DIMM_G1-TMP C0_DIMM_G2-TMP C0_DIMM_H1-TMP Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 78: Psu

    5.5.2.3 PSU The used system power supply (PSU) provides an input and output current draw reading. Both power values are available to read and are supported by BMC as PSU current sensors. Copyright 2024 Advantech Co. Ltd. All rights reserved.
  • Page 79 No part of this publication may be reproduced in any form or by any means, electronic, photocopying, recording or otherwise, without prior written permission of the publisher. All brand and product names are trademarks or registered trademarks of their respective companies. © Advantech Co., Ltd. Copyright 2024 Advantech Co. Ltd. All rights reserved.

This manual is also suitable for:

Fwa-5072-00a1r

Table of Contents