Advertisement

Quick Links

EN
MC2
MC2
USER / INSTALLER MANUAL
v .
REV.
/

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MC2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Motorline professional MC2

  • Page 1 USER / INSTALLER MANUAL REV.
  • Page 2 . CONTENT . SAFETY INSTRUCTIONS INDEX ATTENTION: This product is certified in accordance with European . SAFETY INSTRUCTIONS Community (EC) safety standards. . THE CONTROL BOARD This product complies with Directive 2011/65/EU of TECHNICAL SPECIFICATIONS the European Parliament and of the Council, of 8 June PROGRAMMING PRE-RECOMENDATIONS 2011, on the restriction of the use of certain hazardous .
  • Page 3: Safety Instructions

    . SAFETY INSTRUCTIONS GENERAL WARNINGS who understands the risks and dangers involved. • Children shouldn’t play with the product or opening devices to • This manual contains very important safety and usage information. avoid the motorized door or gate from being triggered involuntarily. very important.
  • Page 4: Warnings For Users

    . SAFETY INSTRUCTIONS health requirements for the use of work equipment workers at the the product is in motion. work of Directive 2009/104/CE of European Parliament and of the RESPONSABILITY Council of 16 September 2009. • Attach the permanent label for the manual release as close as •...
  • Page 5: The Control Board

    . THE CONTROL BOARD . THE CONTROL BOARD TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS • CONNECTOR’S DESCRIPTION The MC2 is a central electronic single phase with incorporated radio, for automation of swing gates. 01 • Earth connection • Power supply 110/230V AC 50-60Hz 02 •...
  • Page 6 . THE CONTROL BOARD . THE CONTROL BOARD PROGRAMMING PRE RECOMENDATIONS PROGRAMMING PRE RECOMENDATIONS Before proceeding to the control board configuration, note the following points listed • PROGRAMMING THE CONTROL BOARD BUTTONS SEL/SET in the table below: SEL button: It makes the selection of the function to change. The se- lection is identified by the flashing of the LED corresponding to the selected function at that time.
  • Page 7 MAIN MENU MAIN MENU This is the main menu of the control board MC2, which has access to the most impor- closing. If the gate is stopped during the closing maneuver, it will stop and will restart tant functions of its operation. The control board is supplied with the active main menu.
  • Page 8 . CONFIGURATION . CONFIGURATION MAIN MENU MAIN MENU • INB. CMD. AP Program working time of the motor without deceleration (Gate closed): TRANSMITTER INHIBITION DURING THE OPENING AND PAUSE TIME 01. Press the SEL button the times necessary until the LED T.MOT. start to flash. With the function activated, the control board rejects all the transmitters signals during 02.
  • Page 9: Extended Menu

    . CONFIGURATION . CONFIGURATION MAIN MENU MAIN MENU Programming pedestrian working time without deceleration (gates closed): Programming: 01. Press the SEL button as often as necessary until the LED T. RIT. ANTE starts flashing. 01. Press SEL button as often as necessary until the T. MOT. PED. LED starts flashing. 02.
  • Page 10 . CONFIGURATION . CONFIGURATION EXTENDED MENU EXTENDED MENU • AUT/P P 03. Press SET button for 1 second. PROGRAMMING OF THE REMOTE CONTROL ON DISTANCE 04. The CODE PED LED ON indicates that the function is activated and the CODE PED The programming the transmitter at distance function, allows them to be added remote LED OFF indicates that the function is disabled.
  • Page 11 . CONFIGURATION . CONFIGURATION EXTENDED MENU EXTENDED MENU Activate (LED ON) / deactivate (LED OFF) function: • AUT/P P | FOLLOW ME 01. Activate the extended menu 1. With the pause time programmed, it is possible to trigger "Follow Me" option. 02.
  • Page 12 . CONFIGURATION . CONFIGURATION EXTENDED MENU EXTENDED MENU • INB. CMD. AP. | PUL= opening, PED= closing (LED ON) / PUL=PUL and PED=PED (LED OFF): SOFT START 01. Enter the extended menu 2. With function "Soft Start" enabled, the beginning of each movement, the control board 02.
  • Page 13: Component Test

    . CONFIGURATION . COMPONENT TEST EXTENDED MENU CAPACITORS CONNECTION SCHEME Motor power programming during the deceleration: To detect if the malfunction is on the control board or on the motor is, sometimes, It is possible to choose up to 6 different levels, relatively the force that the motor per- necessary to perform tests with connection directly to a 110/230V power supply.
  • Page 14: Troubleshooting

    . TROUBLESHOOTING FINAL CONSUMERS INSTRUCTIONS INSTRUCTIONS FOR SPECIALIZED INSTALLERS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem • Motor • Make sure you have • Still not working • Consult a qualified 1 • Open control board and check 3 •...
  • Page 15: Connection Scheme

    . CONNECTION SCHEME COMPONENT'S CONNECTION TO THE CONTROL BOARD Black Blue Brown Brown Blue Black Earth wire Earth wire...