9
Specifications
Electrical Specification
Nominal Voltage
Nominal Capacity
Resistance
Efficiency
Self Discharge
Max. Batteries in Parallel or Series
Cycle Life (25°C)
Design Life
Discharge Specification
Max. Continuous Discharging Current
Peak Discharging Current
Charge Specification
Recommended Charging Current
Max. Continuous Charging Current
Recommended Charging Voltage
Environment Specification
Discharging Temperature
Charging Temperature
Storage Temperature
Operating Temperature
Max. Altitude
Relative Humidity
12.8 VDC
200 Ah
< 10 mΩ
99%
≤ 3% per month
4S4P
﹥ 4000 (80% DOD, 0.5 C, 25 °C)
≥ 10 years
100 A
200 A @5 s
50 A
100 A
14 V ~ 14.6 V
-4 °F ~ 140 °F (-20 °C ~ 60 °C)
32 °F ~ 131 °F (0 °C ~ 55 °C)
-40 °F ~ 140 °F (-40 °C ~ 60 °C)
-4 °F ~ 122 °F (-20 °C ~ 50 °C)
*If charging is required when the temperature is below 32 °F (0 °C),
please connect the charger to enable the heating film. The battery
starts charging when the cell temperature is heated to a certain
temperature.
1
3123 ft (4000 m)
5% ~ 95% (non-condensing)