FK fast clamps, these parts are available and recommended as accessories. Speak to Systemair for more information on how to install the product in different installation locations. Intended use The product is used for transportation of air or explosive at- mospheres with a maximum air humidity of 95%.
Name plate Voltage, V IP class, enclosure class Ambient temperature 10. Speed controllable Systemair Sverige AB Industrivägen 3 739 30 Skinnskatteberg SE 11. Identification number of Notified Body www.systemair.com 12. Equipment group II is intended for use in areas with ex- plosive gas, except mining gas.
Product liability Read the warning instructions that follow before you do work on the product. Systemair is not liable for damages that the product causes in these conditions: • The product is incorrectly installed, operated or • Read this manual and make sure that you understand the maintained.
capabilities, or lack of experience and knowledge, unless Transportation and they have been given supervision or instruction. storage • Do not allow children to play with the product. Warning Personal protective Make sure that the product does not equipment become damaged or wet during transportation.
– To decrease vibrations transmitted from the product to protection is necessary that meet the the duct system, Systemair recommends to install vi- crosscut test parameter of 2 / EN ISO bration dampers, fast clamps or flexible connections.
Installation example is only a guide for installation. The di- mensioning of suspension devices must be carried by the Only FCiC2 from Systemair is tested and approved for 3– installer and adapted to the prevailing conditions. Installa- phase EX fans.
3 mm at each pole. • If a residual current device (RCD) is installed, make sure that it is an all-current sensitive RCD. Warning 1–phase EX fans are not controllable. Note: ATEX approved motor protection is required. Systemair recommend U-EK230E motor protection.
Control panel FCiC2 (accessory) Table 1 Operation keys and potentiometer Name Function Home • Toggles between status view and main menu. • Long press to access the shortcut menu for quickly reading and ed- iting parameters. Stop the FCiC2 in local mode or reset to clear a fault Start in local mode Select between remote or local mode Potentiometer...
Examine the vibrations in the casing and the bearing areas at all speed levels. The commissioning report is found at www.systemair.com. Make sure that the vibrations agree with the specifi- cations in ISO 14694.
Operation To start the product with a speed controller Warning 1–phase EX fans are not controllable. Set the speed controller to position “0”. Install the external speed controller. Refer to the instruc- tion manual for the installed speed controller. To start the product with a FCiC2 Install the FCiC2.
Maintenance Warning Set the installed safety switch in the OFF position before you do the maintenance unless the instructions tell you differently. Make sure that the safety switch is not accidentally set in the ON position. Maintenance schedule The intervals are calculated from continuous operation of the product.
Troubleshooting Note: If you cannot find a solution to your problem in this section, speak to Systemair technical support. Problem Cause Solution The fan impeller is not correctly Speak to Systemair technical support. balanced. There is dirt on the fan impeller.
Connect the capacitor correctly. Refer correctly connected. to the included motor wiring diagram. There is blockage in the motor. Speak to Systemair technical support. Defective motor winding. If it is possible, measure the resistance to do a check of the motor winding.
Warranty For warranty claims, send a written maintenance plan and the commissioning report to Systemair. The warranty is only applicable for these conditions: • The product is correctly installed and operated. • Motor protection is used. • The instructions in the data sheets are obeyed.
Product dimensions Note: If the unit of measure is not specified, the dimensions are given in millimetres. EX 140A–4 23.5 EX 140–4C NC EX 180A–4 23.5 EX 180–4C NC EX 140A–2 23.5 EX 140–2C NC EX 140A–4 ø6 (4x) ø9(4x) ø7(6x) M4(4x) 191.5...
Wiring diagrams EX fans 1–phase 220–240 V EX 140-2C NC EX 140-4C NC EX 180-4C NC EX fans 3–phase 380–440 V (Y) 3–phase 230 V (D) EX 140A-2 EX 140A-4 EX 180A-4...
IGC: Wall grid IS: Inlet sleeve connection Safety switch 10. FCiC2: Frequency converter Note: The selection of accessories shown are not supplied with the product. For more information and other available accessories, refer to www.systemair.com or speak to Systemair technical support.
EU Declaration of Conformity We, the manufacturer Manufacturer Systemair Sverige AB Address Industrivägen 3 739 30 Skinnskatteberg Sweden declare under our sole responsibility that the products Machine Explosion proof fan Type/Model Notified body Number 2460, DNV Product Assurance AS fulfils the relevant provisions of following directives and Electromagnetic compatibility (EMC) –...