Sheets (SDSs). Safety precautions Users of ESAB equipment have the ultimate responsibility for ensuring that anyone who works on or near the equipment observes all the relevant safety precautions. Safety precautions must meet the requirements that apply to this type of equipment. The following recommendations should be observed in addition to the standard regulations that apply to the workplace.
Page 5
If equipped with ESAB cooler Use ESAB approved coolant only. Non-approved coolant might damage the equipment and jeopardize product safety. In case of such damage, all warranty undertakings from ESAB cease to apply. For ordering information, see the "ACCESSORIES" chapter in the instruction manual.
Page 6
For further information contact the nearest ESAB dealer. ESAB has an assortment of welding accessories and personal protection equipment for purchase. For ordering information contact your local ESAB dealer or visit us on our website. 0448 524 001 - 6 -...
2 INTRODUCTION INTRODUCTION Rogue ET 181iP is an inverter-based power source intended for MMA pulse, TIG / GTAW (Tungsten Inert Gas), TIG pulse, and HF TIG / GTAW (High Frequency Tungsten Inert Gas) welding. ESAB accessories for the product can be found in the "ACCESSORIES" chapter of this manual.
3 TECHNICAL DATA TECHNICAL DATA Rogue ET 181iP Outlet voltage 230 V±15% 1~ 50/60 Hz Primary current MMA / SMAW / Stick 36 A TIG / GTAW 24 A No-load power demand when in energy-saving mode 30 W Setting range MMA / SMAW / Stick 20-180 A TIG / GTAW 10-180 A...
Page 9
3 TECHNICAL DATA Rogue ET 181iP Insulation class transformer Enclosure class IP23S Application class Mains supply, S sc min Minimum short circuit power on the network in accordance with IEC 61000-3-12. Duty cycle The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or cut at a certain load without overloading.
Mains supply NOTE! Rogue ET 181iP does not comply with IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be connected.
Page 12
Minimum recommended extension cord size 4 mm NOTE! Different variants of Rogue ET 181iP is certified for different outlet voltages. Always refer to the rating plate for the specification of the power source in use. NOTE! Use the power source in accordance with the relevant national regulations.
Page 15
The VRD function ensures that the open-circuit voltage does not exceed 35 V when welding is not being carried out. This is indicated by a lit VRD indicator on the panel. Contact an authorised ESAB service technician to activate this function. Pulse welding...
Repair and electrical work should be performed by an authorised ESAB service technician. Use only ESAB original spare and wear parts. The Rogue ET 181iP is designed and tested in accordance with the international and European standards EN60974-1 and EN60974-10. On completion of service or repair work, it is the responsibility of the person(s) performing the work to ensure that the product still complies with the requirements of the above standards.
Denomination Type Notes 0705 002 011 Power source Rogue ET 181iP CE, UAE 0448 524 * Instruction manual The three last digits in the document number of the manual show the version of the manual. Therefore they are replaced with * here. Make sure to use a manual with a serial number or software version that corresponds with the product, see the front page of the manual.
Need help?
Do you have a question about the Rogue ET 181iP and is the answer not in the manual?
Questions and answers