Table 1-6. System Messages (continued)
Message
Keyboard data
line failure
Keyboard stuck
key failure
Keyboard fuse has
failed
Manufacturing
mode detected
Memory address
line failure at
address , read
value expecting
value
Memory double
word logic
failure at
address , read
value expecting
value
Memory odd/even
logic failure at
address, read
value expecting
value
Memory
write/read
failure at
address , read
value expecting
value
Memory tests
terminated by
keystroke
Causes
Keyboard cable connector is
loose or improperly
connected, defective
keyboard, or defective
keyboard/mouse controller.
Overcurrent has been
detected at the keyboard
connector.
System is in manufacturing
mode.
Faulty or improperly installed
memory modules.
POST memory test
terminated by pressing the
spacebar.
Corrective Actions
Check the keyboard
connection to the system. If
the problem persists, try
another keyboard, or see
"Getting Help" on page 205.
See "Getting Help" on
page 205.
Restart to take the system
out of manufacturing mode.
See "Troubleshooting System
Memory" on page 174.