Dell PowerEdge DR715 Hardware Owner's Manual page 30

Dell server hardware owner's manual
Table of Contents

Advertisement

Table 1-5. LCD Status Messages (continued)
Code
Text
E201F DRAC Config
E2020 CPU Config
E2021 Memory
Population
E2022 POST Fail
E2110 MBE DIMM # &
#
E2111 SBE Log
Disable DIMM
#
E2112 Mem Spare
DIMM #
30
About Your System
Causes
Dell remote access
controller (DRAC)
configuration failure.
Processor configuration
failure.
Incorrect memory
configuration. Memory
population order incorrect.
General failure after video.
One of the DIMMs in the
set implicated by "# & #"
has had a memory multi-bit
error (MBE).
The system BIOS has
disabled memory single-bit
error (SBE) logging, and will
not resume logging further
SBEs until the system is
restarted. "#" represents the
DIMM implicated by the
BIOS.
The system BIOS has spared
the memory because it has
determined that the
memory had too many
errors. "# & #" represents
the DIMM pair implicated
by the BIOS.
Corrective Actions
Check screen for specific
error messages.
Ensure that DRAC cables
and connectors are
properly seated. If
problem persists, see your
DRAC documentation.
Check screen for specific
error messages.
Check screen for specific
error messages (see
"Troubleshooting System
Memory" on page 174).
Check screen for specific
error messages.
See "Troubleshooting
System Memory" on
page 174.
See "Troubleshooting
System Memory" on
page 174.
See "Troubleshooting
System Memory" on
page 174.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge t605

Table of Contents