Dell PowerEdge DR715 Hardware Owner's Manual page 19

Dell server hardware owner's manual
Table of Contents

Advertisement

CAUTION:
Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. See your Product
Information Guide for complete information about safety precautions, working
inside the system, and protecting against electrostatic discharge.
NOTE:
If your system fails to boot, press the System ID button for at least five
seconds until an error code appears on the LCD. Record the code, then see "Getting
Help" on page 205.
Table 1-5. LCD Status Messages
Code
Text
SYSTEM NAME
N/A
E1000 FAILSAFE,
Call Support
E1114 Temp Ambient Ambient system
E1118 CPU Temp
Interface
E1210 CMOS Batt
Causes
A 62-character string that
can be defined by the user in
the System Setup program.
The SYSTEM NAME
displays under the following
conditions:
• The system is powered on.
• The power is off and
active errors are displayed.
Check the system event log
for critical failure events.
temperature is out of
acceptable range.
The BMC is unable to
determine the processor(s)
temperature status.
Consequently, the BMC
increases the processor fan
speed to maximum
as a precautionary measure.
CMOS battery is missing, or
the voltage is out of
acceptable range.
Corrective Actions
This message is for
information only.
You can change the
system ID and name in
the System Setup
program (see "Entering
the System Setup
Program" on page 43).
See "Getting Help" on
page 205.
See "Troubleshooting
System Cooling
Problems" on page 172.
Turn off power to the
system and restart the
system. If the problem
persists, see "Getting
Help" on page 205.
See "Troubleshooting the
System Battery" on
page 170.
About Your System
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge t605

Table of Contents