Download Print this page

Advertisement

Quick Links

IN240500232V01_UK
821-036V70
US_CA

Advertisement

loading
Need help?

Need help?

Do you have a question about the 821-036V70 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HOMCOM 821-036V70

  • Page 1 IN240500232V01_UK 821-036V70 US_CA...
  • Page 2 Please take a few moments to read the instructions thoroughly and familiarize yourself with all the operational aspects of this dehumidifier. This unit removes unwanted moisture from the air to create a more comfortable environment in your home or office. It can be conveniently moved from room to room within your home.
  • Page 3 13. The appliance shall be installed in accordance with local national wire regulations. 14. The appliance can not be used in public transportation. 15. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 4 B Warring for disposal: It is prohibited to dispose of this appliance in domestic household waste. For disposal there are several possibilities 1 Do not dispose this product as unsorted municipal waste. .Collection of such waste separately for special treatment is necessary. 2 The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
  • Page 5 PRODUCT DIAGRAM Parts 1.Control panel 2.handle 3.Air outlet 4.Caster 5.Filter Box 6.Water Tank 7.Supply Cord OPERATING INSTRUCTIONS Operation buttons lndicator light...
  • Page 6 Humidity Level & Timer 2 digit display The indicator features 3 functions:。 1. when the unit is plugged in, it will indicate the room humidity level. 2. when you set the humidity, it will indicate the humidity that you have selected 3.
  • Page 7 The switch will disable the timing function, but it will not disable the timing function when the water is full. DRAINING THE COLLECTED WATER When the drainage tank is full, the tank full indicator light will turn on, the operation will stop automatically and the buzzer will beep 15 times to alert the user, that the water need to be emptied from the drainage tank .
  • Page 8 NOTE 1. If the drainage tank is dirty, wash it with cold or lukewarm water. Do not use detergent, scouring pads, chemically treated dust cloths, gasoline, benzene, thinner, or other solvents, as these can scratch and damage the tank and cause water leakage 2.
  • Page 9 MAINTENANCE Cleaning the Dehumidifier To clean the Body Wipe it with a soft damp cloth. To Clean the Air Filter 1.Open the inlet grill firstly and remove the air filter filter Clean the air filter Run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is exceptionally dirty, wash it with warm water and a mild cleanser and dry thoroughly.
  • Page 10 3. Attach the air filter Insert the filter into the grill smoothly, and place the inlet grill into right place. Storing the Dehumidifier When the unit is not being used for a long period of time and you want to store it note the following steps: 1 .
  • Page 11 TROUBLESHOOTING If a condition listed below occurs, please check the following items before calling customer service. Problem Possible Cause Solution Has the power cord been disconnected? Plug the power cord into the outlet. Is the tank full indication lamp blinking? Empty the water in the drainage (The tank is full or in a wrong position.) tank and then reposition the tank.
  • Page 12 5.No ignition sources No person carrying out work in relation to a refrigerant system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
  • Page 13 Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres, Replacement parts shall be in accordance with the manufacturer’s specifications. NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment.
  • Page 14 Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved , then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system.
  • Page 15 18.Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely. When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge are available.