AXIAL FAN
Calm Design 100
User's manual - Blauberg UK

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Calm Design 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLAUBERG Ventilatoren Calm Design 100

  • Page 1 AXIAL FAN Calm Design 100 User’s manual - Blauberg UK...
  • Page 2: Table Of Contents

    CONTENTS Delivery set ................................................7 Brief description ..............................................7 Operation guidelines ............................................7 Designation key ..............................................8 Installation................................................9 Fan operation setup ............................................10 Technical maintenance ........................................... 11 Troubleshooting ..............................................11 Storage and transportation regulations ....................................12 Manufacturer’s warranty ..........................................13 This user’s manual is a main operating document intended for technical, maintenance, and operating staff.
  • Page 3 PLEASE READ THE USER’S MANUAL CAREFULLY PRIOR TO INSTALLING, CONNECTION TO POWER MAINS AND OPERATING THE UNIT. THE MANUFACTURING COMPANY SHALL NOT BE RESPONSIBLE FOR DAMAGE TO HEALTH AND PROPERTY OF THE CUSTOMER CAUSED BY THE CUSTOMER’S VIOLATING THE USER’S MANUAL. FOLLOW THE USER’S MANUAL REQUIREMENTS TO ENSURE DURABLE OPERATION OF THE UNIT, ITS MECHANICAL AND ELECTRICAL RELIABILITY.
  • Page 4 of any foreign objects that can damage the impeller blades. While mounting the unit, avoid compression of the casing! Deformation of the casing may result in motor jam and excessive noise. Misuse of the unit and any unauthorised modifications are not allowed.
  • Page 5 order to incorporate the latest technological developments. Never touch the unit with wet or damp hands. Never touch the unit when barefoot. This unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety.
  • Page 6 Ensure that the unit is switched off from the supply mains before removing the guard. THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE. DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
  • Page 7: Delivery Set

    DELIVERY SET Fan — 1 pc. Screws and dowels — 4 pcs. Plastic screwdriver (only for models with a timer) — 1 pc. User’s manual — 1 pc. Packing box — 1 pc. Sealing gasket — 1 pc. BRIEF DESCRIPTION The product is an axial fan for exhaust ventilation of small and medium-sized premises.
  • Page 8: Designation Key

    SТ: pull cord switch and turn-off delay timer H: humidity sensor and turn-off delay timer SH: pull cord switch and humidity sensor IR: motion sensor Outlet duct diameter [mm] 100/125 Motor modification _: single-speed motor V2: double-speed motor Fan series Calm Design 100...
  • Page 9: Installation

    INSTALLATION The fan is designed for wall or ceiling mounting with direct air discharge to the ventilation shaft or into the round air duct of matching diameter (Fig. 2). Fan installation with direct air discharge upwards is not allowed (Fig. 2). Fan installation sequence: Step 1.
  • Page 10: Fan Operation Setup

    FAN OPERATION SETUP THE TIMER CIRCUIT IS LIVE. MAKE SURE THE FAN IS DISCONNECTED FROM POWER SUPPLY. i — interval timer turning on and adjustment is performed with the potentiometer T . To turn the interval timer off, set the potentiometer Ti into the leftmost position. Rotation of the potentiometer for 1/3 clockwise sets the interval timer operation for 6 hours, rotation of the potentiometer for 2/3 clockwise sets the interval timer operation for 12 hours, and rotation of the potentiometer clockwise in the rightmost position sets the interval timer operation for 24 hours.
  • Page 11: Technical Maintenance

    TECHNICAL MAINTENANCE The fan maintenance periodicity is at least once per 6 months. Maintenance steps: • Disconnect the fan from power supply and make sure electricity has been turned off (Fig. 21). • Remove the front panel, wipe the fan with a dry cloth or a brush (Fig. 22). •...
  • Page 12: Storage And Transportation Regulations

    STORAGE AND TRANSPORTATION REGULATIONS • Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °C to + 40 °C and relative humidity up to 70 %. • Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
  • Page 13: Manufacturer's Warranty

    MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/ EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 14 • Replacement and use of any assemblies, parts and components not approved by the manufacturer. • Unit misuse. • Violation of the unit installation regulations by the user. • Violation of the unit control regulations by the user. • Unit connection to power mains with a voltage different from the one stated in the user's manual. •...
  • Page 15 Dimensions [mm] Ø D Sileo 100 Sileo 125 Calm Design 100...
  • Page 16 Latches...
  • Page 17 ...100/125 ...100/125 Fan does not run. L(2) N(3) S switch to ON or pull cord switch L(2) N(3) Fan runs ...100/125 S S switch to OFF or pull cord switch L(2) N(3)
  • Page 18 ... 100/125 T/TR LT(1) Fan does not run. Fan does not run. L(2) N(3) S switch to ON S switch to ON LT(1) or pull cord switch or pull cord switch L(2) N(3) Activation of turn-on Fan runs delay timer (0-2 minutes) ...
  • Page 19 ... 100/125 H LT(1) Fan does not run L(2) N(3) S switch to ON or pull cord switch LT(1) Humidity exceeds L(2) set point N(3) Fan runs ... 100/125 SH S switch to OFF or pull cord switch L(2) Fan runs N(3) Humidity is Humidity exceeds...
  • Page 20 ... 100/125 IR LT(1) Fan does not run L(2) N(3) Motion detected Fan runs No motion detected Activation of turn-off delay timer (2-30 minutes)
  • Page 21 ... V2 100/125 ... V2 100/125 (speed 1) LT(1) Fan does not run. L(2) N(3) S switch to ON or pull cord switch LT(1) L(2) N(3) Fan runs at speed 1 ... V2 100/125 S (speed 1) S switch to OFF or pull cord switch LT(1) L(2)
  • Page 22 speed 1 and 2 ... V2 100/125 (speed 1 and 2) speed LT(1) Fan does not run L(2) N(3) S switch to ON speed LT(1) or pull cord switch L(2) N(3) ... V2 100/125 S (speed 1 and 2) LT(1) L(2) Speed switch speed...
  • Page 23 ... V2 100/125 LT(1) LT(1) L(2) L(2) N(3) N(3) Off 6/12/24 hours Interval timer The fan does not run Fan runs at speed 1 Contact of the S switch Contact of the S switch Start of interval or the pull cord switch is or the pull cord switch is timer (6, 12 or 24 hours) CLOSED...
  • Page 24 ... V2 100/125 H LT(1) Fan runs at speed 1 L(2) N(3) Contact of the S switch or the pull cord switch is CLOSED LT(1) Humidity exceeds set point Activation of turn-on L(2) delay timer (60 seconds) N(3) Activation of turn-on delay timer (60 seconds) The contact of the S switch or the pull cord switch is...
  • Page 25 Latches...
  • Page 27 Quality Inspector’s Stamp Sold by (name and stamp of the seller) Manufacture Date Purchase Date...
  • Page 28 Sileo __________________________________________________________ www.blauberg.co.uk...