BLAUBERG Ventilatoren BOX Series Operation Manual

Inline ?entrifugal fan
Hide thumbs Also See for BOX Series:

Advertisement

Quick Links

INLINE СENTRIFUGAL FAN
BOX
BOX-R
OPERATION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for BLAUBERG Ventilatoren BOX Series

  • Page 1 INLINE СENTRIFUGAL FAN BOX-R OPERATION MANUAL...
  • Page 2: Table Of Contents

    Box & Box-R www.blaubergventilatoren.de CONTENT Introduction General Safety rules Storage and transportation rules Manufacturer’s warranty Fan design Delivery set Technical data Mounting and operation guidelines Connection to power mains Maintenance Fault handling Acceptance certifi cate Electrical connection certifi cate Warranty card...
  • Page 3: Introduction

    Box & Box-R www.blaubergventilatoren.de BLAUBERG Company is happy to off er your attention a new high-quality equipment to prevent back drafting. The maximum permitted pressure inline centrifugal Blauberg Box & Box-R fans. diff erence per living units is 4 Pa. The air must not contain any dust or other solid impurities, sticky substances INTRODUCTION or fi brous materials.
  • Page 4: Fan Design

    Box series are the single-speed fans. to the back or front wall of the casing, depending on the fan model.
  • Page 5: Technical Data

    Box & Box-R www.blaubergventilatoren.de TECHNICAL DATA Table 1. Main technical parameters Parameters Max. Fan type Sound transported Voltage, Max. current Max. air fl ow Speed Power [W] pressure level, 50 Hz [V] [min 3 m [dB(A)] temperature [°C] 0.32 1400 Box-R 80 0.34 1800...
  • Page 6 Box & Box-R www.blaubergventilatoren.de Table 2. Overall dimensions Dimensions [mm] Weight Fan type Figure [kg] ØD ØD1 Box-R 80 Box-R 100 Box 100 Box 125 Box 150 Box 160 Box-R 80/80х2 Box-R 100/80х2 Box-R 100/100х2 Box 125/100х2 Box 150/125х2 Box-R 80/80х4 Box-R 100/80х4 Box-R 100/100х4 Box-R 125/100х4...
  • Page 7: Mounting And Operation Guidelines

    Box & Box-R www.blaubergventilatoren.de MOUNTING AND OPERATION GUIDELINES After unpacking, prior to mounting:  read carefully the user manual and mounting, set-up, operation and maintenance instructions;  check the fan for possible transportation damages; Follow the safety requirements during the fan setup and operation. Mounting: If the fan branch pipe must be capped, lubricate the rubber fan seal with silicone grease.
  • Page 8 Box & Box-R www.blaubergventilatoren.de  install the fan on the fi xing bracket (fi g. 3c); Fan mounting sequence:  make sure that power supply to the fan is cut off ;  tighten the screws (fi g. 3d);  mark the holes for the fi xing bracket on the bearing surface (table 3, ...
  • Page 9: Connection To Power Mains

    Box & Box-R www.blaubergventilatoren.de CONNECTION TO POWER MAINS Connection of the fan to power mains is allowed by a qualifi ed electrician Connect the fan to power mains through the terminal block incorporated only. The rated electrical parameter are stated on the rating plate. inside the terminal box on the fan casing in compliance with the fan wiring No modifi cations of internal connections are allowed and will result in void diagram in fi g.
  • Page 10: Maintenance

    Box & Box-R www.blaubergventilatoren.de MAINTENANCE Disconnect the fan from power mains prior to maintenance and servicing Maintenance sequence: operations and check that the rotating parts do not move. 1) cut off power supply to the fan, fi g. 6 a; Maintenance means regular cleaning of the fan surfaces from dust and dirt.
  • Page 11: Acceptance Certificate

    Box 125/100x2 Box-R 80/80х5 Box-R 100/100х2 Box 125/100x4 Box-R 80/80х6 Box-R 100/100х4 Box 150 Box-R 100 Box-R 100/100х5 Box 150/125x2 Box-R 100/80х2 Box-R 100/100х6 Box 160 SELLER SALES DATE REPRESENTATIVE IN EU Blauberg Ventilatoren GmbH Aidenbachstr. 52a, D-81379 München, Deutschland...
  • Page 12 www.blaubergventilatoren.de Box_Box-R/ v.1(3) / 08-2014 / EN...

Table of Contents