SunSynk Lifelynk Lynks 8kW User Manual
SunSynk Lifelynk Lynks 8kW User Manual

SunSynk Lifelynk Lynks 8kW User Manual

Hide thumbs Also See for Lifelynk Lynks 8kW:

Advertisement

Quick Links

Lifelynk Lynks 8kW
SM8.0kWLLL
USER MANUAL
www.sunsynkmobile.com / sales@sunsynkmobile.com
Please retain for
125
future reference

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lifelynk Lynks 8kW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SunSynk Lifelynk Lynks 8kW

  • Page 1 Lifelynk Lynks 8kW SM8.0kWLLL USER MANUAL www.sunsynkmobile.com / sales@sunsynkmobile.com Please retain for future reference...
  • Page 2 Fault Codes Parallel Operation External Battery and Parallel Connections COMMISSIONING Load Connection Startup / Shutdown Procedure Grid Connection Information for Commissioning the Inverter Solar Connection GFDI Fault LCD DISPLAY SCREEN MAINTENANCE FACTORY SETTINGS APPENDIX A SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 3: General Safety Information

    Therefore, after turning off the power, always wait 5 minutes before touching electrical components. This unit contains no user-serviceable parts. Always consult an authorised contractor for repairs. ƒ SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 4: Symbols In The Manual

    Do not drop, deform, or impact the Ground Terminal. inverter. Single Phase. Three Phase. Do not submerge the inverter in water or Keep out of reach of children, animals, expose it to moisture or liquid. and insects. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 5: Manual Download

    Electrical devices should be disposed of in accordance with regional directives on electronic and / or electronic-waste disposal. In case of further questions, please consult your supplier. In some cases, the supplier can take care of disposal. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 6: Product Introduction

    Data logger (Sunsynk Wi-Fi) • CT Coil (2 pin AERO - female connector) • 1x3 pin AC Load connector (female) • 2 x MC4 connectors • 1x3 pin AC Grid connector (male) • 2x Battery Connectors SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 7: Technical Specification

    TECHNICAL SPECIFICATION Pure sine wave inverter with a maximum input power of 10kW. ƒ MPPT charge controller feature. ƒ Bi-directional inverter that can rapidly charge external external batteries. ƒ SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 8 Nominal Input/Output Frequency 50/60Hz (Auto Adjusted to Fit Home Grid) Max. Bypass Current Shift Time (Bypass and Inverter) 10ms Efficiency Max. Efficiency 97.6% Max. Battery to Load Efficiency 94.0% Europe Efficiency 97.6% MPPT Efficiency 99.9% SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 9: Installation

    Areas that can cause combustible gas to leak, which contains suspended carbon-fibre, flammable dust or ƒ volatile inflammability such as paint thinner or gasoline. Areas where there may be gas leaks and where gas may settle around the unit, as this is a fire risk. ƒ SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 10: Mounting The Inverter

    / front) to guarantee heat dissipation and easy access to the wiring / cabling. CAUTION Risk of Injury (Heavy Object) Remember that this inverter is heavy, so users must be careful in handling the unit during installation especially when mounting or removing from a wall. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 11: Battery Cable Connection

    Battery Cable Connection 13.0 mm 10 mm SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 12: Flow Diagram

    Also, the open-circuit voltage (Voc) of the PV modules does not exceed the maximum input voltage of the ƒ inverter. Also, the Voc of the PV array should be higher than the minimum starting voltage of the inverter. Connect the PV panels into the MC4 connectors. ƒ SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 13 Feed cable back to Lynks 8kW Connect into CT/ Limiter Port You can access the CT Coil Screen directly from the Home Screen by pressing the Home/Back button: Essential Load Home Load Power Power Power SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 14: External Battery Pack

    3-4 minutes. After that, the device should return to its normal working condi- tion, with the error cleared. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 15 External Battery and Parallel Connections SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 16 SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 17 Load Connection Grid Connection SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 18: Solar Connection

    Solar Connection SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 19: Lcd Display Screen

    17 : 12:51 12.93A :37.5℃ & to navigate backwards. TYPE INDICATION DESCRIPTION GREEN CHARGING BATTERY BLUE DISCHARGING GREEN AC CONNECTED AC OFF GREEN SOLAR ON SOLAR SOLAR OFF GREEN INVERTER RUNNING NORMAL SYSTEM FAULT INVERTER NOT RUNNING SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 20: Factory Settings

    Default Setting 00:00 6:00 3000W 52.0V 6:00 12:00 3000W 52.0V 12:00 18:00 3000W 52.0V 18:00 23:59 3000W 52.0V BATTERY COMPATIBILITY The following batteries are compatible with Sunsynk Mobile Lynks Inverter: SUN-BATT-5.32 ƒ SUNSYNK-L5.3 ƒ L051069-A ƒ SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 21: Operation

    3000W 52.0V Year Energy 3600KWh Enable Low Battery Earth Neutral Bond 49.0V Max Grid Freq 52.0Hz 18:00 23:59 3000W 52.0V Total Energy 7200KWh Night Power Saving Enable Float Charge 56.0V Voltage AC 230V Frequency 50Hz SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 22: Switching On/Off

    What you can do from this page If you press the select button you can navigate to the basic setup menu If Sunsynk Connect has been connected, the WI-FI icon appears Access the CT screen by pressing the Home/Back button...
  • Page 23: Home Settings

    Set Date 15-05-2023 15-05-2023 Set Date Backlight Backlight Standalone Standalone Work Mode Work Mode Voltage SOC/Voltage SOC/Voltage Factory Reset Factory Reset What does this page display? Time Date Backlight on / off Work Mode SOC/Voltage Reset SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 24: Save Settings

    Change the language settings via the “Basic Settings” page by pressing the “Factory Reset” button. Then a password input page will be shown. The default password is “1234”. Basic Settings Set Time 15:16 Please Input the Password Set Date 15-05-2023 Backlight **** Standalone Work Mode SOC/Voltage SOC/Voltage Factory Reset Factory Reset SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 25 Change the language settings via the “Basic Settings” page by pressing the “Factory Reset” button. Then a password input page will be shown. The default password is “1234”. Basic Settings Set Time 15:16 Please Input the Password 15-05-2023 Set Date Backlight **** Standalone Work Mode SOC/Voltage SOC/Voltage Factory Reset Factory Reset SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 26 Change the work mode settings via the “Basic Settings” page by pressing the “Work Mode” button. Then a password input page will be shown. The default password is “1234”. Basic Settings Set Time 15:16 Please Input the Password 15-05-2023 Set Date Backlight **** Standalone Work Mode Work Mode SOC/Voltage SOC/Voltage Factory Reset SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 27 Daily Energy 1KWh Daily Energy 1KWh Monthly Energy 30KWh Monthly Energy 30KWh Year Energy 3600KWh Year Energy 3600KWh Total Energy 7200KWh Total Energy 7200KWh What does this page display? Solar production icon Grid production icon SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 28: Advance Setting

    What does this page display? Grid Settings page icon System Configuration page icon Battery Settings page icon System Controller page icon What you can do from this page You can access the grid, system, inverter, and battery setting pages. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 29: Grid Settings

    Charge from AC Low Battery Low Battery 49.0V Float Charge Float Charge 56.0V 56.0V What does this page display? Low battery SOC/Voltage Reboot SOC/Voltage Maximum charge current Charge from the mains Low Battery SOC/Voltage Float charge SOC/Voltage SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 30: System Config

    If Earth Neutral Bond is enabled, the relay will make and earth neutral bond on the load port of the inverter after the grid power fails. This is for earth leakage devices to function correctly on this island circuit. The Night Power Saving can be set to “Enable” or “Disable”. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 31: Export Control

    Export Sell to Grid 1. Press the Settings button on the main screen. 2. Select Advanced Settings. Home Settings 1:3500W/400V 7680W/ 2:3500W/400V 232V Basic System Logger 52.6V/ 232V/ 50.0Hz 10-09-2024 17 : 12:51 12.93A :37.5℃ Fault Codes Advanced SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 32 Which operating mode the machine is working in is shown in the following screens: Essential Load Home Load Essential Load Home Load Power Power Power Power Power Power Essential Load Home Load Power Power Power Sell SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 33: System Controller

    GRID earth when GRID has power. When it is set to “Disable”, this function will not be available. Export Control Export Control Enable Enable Earth Neutral Bond Earth Neutral Bond Disable Night Power Saving Enable Night Power Saving Enable SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 34 AC is off, the UPS function shift time will be longer, can’t be immediate, it will take around 30 seconds. When there is PV power input, then the inverter’s DC to DC converting will work again, because without this converting, the batter packs can’t be charged. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 35: Setting Details

    56V and set all time range to Y. Start to charge battery time by selecting the Charge Y or N System Controller Time Start Time Stop Power %/Voltage Charge 00:00 06:00 3000W 100% 06:00 12:00 3000W 100% 12:00 18:00 3000W 100% 18:00 23:59 3000W 100% SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 36 Earth Neutral Bond Float Charge Night Power Saving Enable 56.0V System Controller Time Start Time Stop Power %/Voltage Charge 00:00 06:00 3000W 52.0V 06:00 12:00 3000W 52.0V 12:00 18:00 3000W 52.0V 18:00 23:59 3000W 52.0V SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 37 System Controller Time Start Time Stop Power %/Voltage Charge 00:00 06:00 3000W 06:00 12:00 3000W 12:00 18:00 3000W 18:00 23:59 3000W If the low battery voltage is set higher, the %voltage will be placed higher accordingly. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 38: Fault Codes

    1. Power supply failure, update power board. Working mode change Inverter work mode changed: 1. Reset the inverter. 2. Seek help from Sunsynk Mobile. Short circuit protecting Short circuit fault: 1. Maintain the connection. 2. Proceed to the settings to modify the work mode.
  • Page 39 3. If the fault exists, please contact us for help. Load current exceeding 1. Try tu reduce the load power. 2. Seek help from Sunsynk Mobile. Over Load Protection 1. Reduce appliance power on LOAD side (sys- tem will auto-reboot in 2 minutes).
  • Page 40: Startup / Shutdown Procedure

    (Refer to the relevant content of the App user manual). Bus one shutdown 1. Reset the inverter. 2. Seek help from Sunsynk Mobile. DRMs0 stop Reserved Error code FAN Error 1. A technician needs to check the internal fan wire or replace fan.
  • Page 41 This is the heart of the Ensure you are familiar with system, this controls every- this, if you fully understand thing. the controller you will fully appreciate the capabilities of there inverter. Familiarise yourself with common fault codes. SM8.0kWLLL - Lifelynk Lynks 8kW...
  • Page 42: Gfdi Fault

    2. Be of the type specified in the inverter manufacturer’s instructions or as labelled on the inverter. We recommend the use of an RCD on all circuits and sub circuits connected to the Sunsynk Mobile inverter. Residual current breaker with overcurrent protection (RCBO).
  • Page 43 Address HK: Room 702-704, 7/F Texwood Plaza, 6 How Ming Street, Kwun Tong, Kowloon, Hong Kong. UK: Sunsynk UK Ltd, 17 Turnstone Business Park, Mulberry Avenue, Widnes, Cheshire, WA8 0WN. SA: Unit 2, 3 & 4, 80 Highview Blvd, Ferndale, Randburg, 2160, South Africa.

This manual is also suitable for:

Sm8.0kwlll

Table of Contents