  • Page 1 INSTALLATION INSTALLATION INSTRUCTIONS Technician HYDRO C2 Indoor unit System ADAPT, VERSI...
  • Page 2 Installation instructions Hydro C2 System ADAPT, Versi THE KRONOTERM INSTRUCTION SYSTEM This document is a part of the KRONOTERM instruction system, which follows our products’ lifecycle from design phase to service support. 17-21-25-10070-00_Installation instructions_Hydro C2_EN Printed in Slovenia, all publication rights reserved by Kronoterm d.o.o.
  • Page 3: Table Of Contents

    Installation instructions Hydro C2 System ADAPT, Versi T A B L E O F C O N T E N T S IMPORTANT INFORMATION ��������������������������������� 4 SYMBOLS ..................4 GENERAL WARNINGS ............4 SAFETY WARNINGS AND INSTRUCTIONS ....5 DISPOSING OF PACKAGING AND THE APPLIANCE ITSELF ..............5...
  • Page 4: Important Information

    Installation instructions Hydro C2 System ADAPT, Versi IMPORTANT INFORMATION NOTE These instructions describe the appliance Before beginning installation, read these installation and maintenance process. Only instructions thoroughly� properly qualified individuals may install or maintain Kronoterm appliances. Read the Any processing or replacement of the appliance’s original integral parts will...
  • Page 5: Safety Warnings And Instructions

    Installation instructions Hydro C2 System ADAPT, Versi 1�3� SAFETY WARNINGS AND WARNING INSTRUCTIONS This appliance is not to be played with� DANGER The appliance may only be used by people who have learned about its safe operation Do not clean the appliance or interfere with and who understand the potential dangers it while it is in operation�...
  • Page 6: Included Parts

    Installation instructions Hydro C2 System ADAPT, Versi 1�5� INCLUDED PARTS Upon delivery of the indoor unit you will receive the following components: Figure 1: Included parts for indoor unit Indoor unit Hydro C2 Additional equipment: Temperature sensor PT1000 Z-J IP65...
  • Page 7: Installation

    Installation instructions Hydro C2 System ADAPT, Versi INSTALLATION 2�1� INSTALLING THE INDOOR UNIT 2�1�1� REQUIRED CLEARANCE NOTE Choose a location for the indoor unit’s installation. For the place of installation, necessary distances, and proper site of installation, look in the instructions for preparing the ADAPT or VERSI heat pump�...
  • Page 8: Connecting The Hoses

    Installation instructions Hydro C2 System ADAPT, Versi 2�1�2� LEVELLING 2�2�1� ATTACHING THE HOSE FOR THE CONDENSATE DRAIN Figure 4: Attaching the hose for the condensate drain 1. Thread the hose for the condensate drain through theØ50 drain. 2. Install the appliance upright.
  • Page 9 Installation instructions Hydro C2 System ADAPT, Versi 2�2�3� CONNECTING THE HOSE TO THE HEATING SYSTEM Figure 6: Connecting the heating system’s hose Heating/cooling – return pipe* – G1'' IT Heating/cooling – supply pipe* – G1'' IT *Flat seal screw Attach the pipe fittings. Use a counter wrench.(Figure 2�2�4�...
  • Page 10: Turning On The Electricity

    Installation instructions Hydro C2 System ADAPT, Versi TURNING ON THE ELECTRICITY 3�1� PREPARATION 3�1�1� REMOVING THE SIDE PANELS Figure 10: Unscrewing the two screws on the front, upper side panel� Removing the front upper side panel� 1. Lift the side panel.
  • Page 11: Where To Connect The Electric

    Installation instructions Hydro C2 System ADAPT, Versi 3�2� WHERE TO CONNECT THE ELECTRIC 3�3� CONNECTING THE INDOOR UNIT TO ELEMENTS POWER SUPPLY Electrical system elements connect to the terminals in CAUTION electrical box. Connect the appliance to the grid using a H05VV power cable (or similar) with an appropriate conductor cross-section�...
  • Page 12 Installation instructions Hydro C2 System ADAPT, Versi 3�3�1� THREE-PHASE CONNECTION 3N ~ 400 V / 3�3�2� SINGLE-PHASE POWER – 1N ~ 230 V/50 HZ 50 HZ If you have single-phase power, you can connect a 2 kW (Figure 15) or 4 kW (Figure 16) electric heater in the indoor unit.
  • Page 13: Connecting The Controller And The Thermostats

    Installation instructions Hydro C2 System ADAPT, Versi 3�4� CONNECTING THE CONTROLLER AND 3�5� CONNECTING THE COMMUNICATION THE THERMOSTATS CABLE TO THE OUTDOOR UNIT Ready the communication cable (FTP 5e) for connection between the indoor unit and outdoor unit as follows:...
  • Page 14: Connecting The Controlling

    Installation instructions Hydro C2 System ADAPT, Versi 1. Wire the communication cable (Figure 18) to the CAUTION electrical box through the cable channel on the left side (Figure 19). Use circulation pumps with PWM 2 signal for the 2.1 Connect wires 1 and 3 (Figure 18) to terminal A+ circulation pump of the heating loops (Solar)�...
  • Page 15 Installation instructions Hydro C2 System ADAPT, Versi 3�6�4� CONNECTING THE CIRCULATION PUMP TO CIRCULATE DHW MODBUS P. SUPPLY 12 V ~400 V ~230 V ~230 V Figure 23: Connecting the power cable of the circulation pump to circulate DHW 1. Thread the power cable of the circulation pump for circulating DHW to the electrical box through the cable channel on the right side (Figure 23).
  • Page 16: Echnical Characteristics

    Installation instructions Hydro C2 System ADAPT, Versi ECHNICAL CHARACTERISTICS 4�1� TERMINALS OF THE KSM REGULATOR MODBUS P. SUPPLY 12 V 28-19-36-6663-00 Figure 25: KSM regulator Label Description Label Description Temperature – DHW tank Input – cooling activation Temperature – outdoor Output –...
  • Page 17: Maintenance

    Installation instructions Hydro C2 System ADAPT, Versi MAINTENANCE CAUTION The wiring and other hardware must be inspected visually once per year� If any faults or malfunctions are found, contact an authorized technician� Order a service inspection from an authorized technician once per year�...
  • Page 18 Installation instructions Hydro C2 System ADAPT, Versi 17-21-30-10070-00...