2. The screen will display ".". Press the Mode button. The screen will show "",
indicating the lb/kg unit switch is enabled. To leave the unit switch function enabled
press the Mode button. To disable the lb/kg unit function, press the Lb/Kg or ZERO
button to toggle the display to "". Press the Mode button.
3. The screen will display "". Press the mode button. The screen will show the
current Motion Detect setting. When the motion detect function is enabled, any
motion detected of the load will disable the scale zero, TARE, print and accum
functions. Pressing the Lb/Kg or the ZERO buttons will toggle through the motion
detect settings. When the desired setting is displayed, press the Mode button.
4. The screen will display ".". Press the Mode button. The screen will show the
current ADC setting in flashing mode. This function enables the internal A/D
conversion time to either full conversion or reduced conversion. Enter "0" to enable
full conversion. Full conversion time provides the most stable results. Enter "1" to
enable reduced conversion time. Reduced conversion time may extend battery life.
Intercomp recommends the conversion setting to be set to "0". It should be noted
that when the conversion setting is changed, the scale must be recalibrated. The
flashing digit may be incremented by pressing the Lb/Kg button or decremented by
pressing the ZERO button. When the desired ADC rate is selected press the Mode
button.
5. The screen displays "". Press the Mode button. The screen shows the current
Auto Zero Tracking (AZT) setting. Press either the Lb/Kg or the ZERO button to
toggle through the auto zero tracking options (, , .. or .). If
after a period of time the displayed weight is less than the number of grads shown,
the weight will be zeroed off. When the correct auto zero tracking setting is
selected, press the Mode button.
6. The screen will display ".". Press the Mode button. The screen shows the
current Zero Range setting in flashing mode. The flashing digit may be incremented
by pressing the Lb/Kg button or decremented by pressing the ZERO button. Zero
range is the percentage the zero can move from the original zero point acquired at
calibration. The ZERO button will not operate if outside the zero range. When
outside the zero range, the screen will display ".". The error icon will also be
displayed if the zero range is set to 1, 2 or 3. If settings 4 through 6 are selected,
the zero button will not function when attempting to zero the scale outside the
range. When the desired zero range number is selected (0=off, 1=1%, 2=2%,
3=5%, 4=1%, 5=2%, 6=5%), press the Mode button.
7. The screen displays "G". Press the Mode button. The display shows the current
Graduation Size setting in flashing mode. Press either the Lb/Kg or the ZERO
buttons to cycle through the graduation options. When the desired graduation
setting is displayed (grad options 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100,
200, 500 or 500) press the Mode button.
After completing Step 7, the screen will display "" for approximately 1 second and
then advance to "".