Page 1
Installation Manual MPCG Vintage The FRIAX INDUSTRIE ranges are constantly evolving to always better protect the wine. The information in this document may change without prior notice to follow our quality commitment. EN-NT-MPCG-0924...
Page 2
Warning Read the manual carrefully before using the device and keep it for futur reference. This symbol indicates that the installation manual should be read carrefully. This symbol indicates that a technician must handle this equipment in referring to the installation manual. This symbol indicates that information are available, such as the manual operating instructions or installation manual.
Page 3
- 1 x Black plexiglass front. - 1 x remote control box with its probe. - 1 x power cords. Dimensions hors palette: - 1 x drain tube. 800mm x 600mm x 1000mm ( P x L x H) - 1 x bag of accessories. 60kg Add 300mm to the Height for the addition of a 2nd facade...
Page 4
Summary Dimensions 7-11 12-17 Electrical diagram and warning Non Isolée Isolation Moyenne Bonne Isolation* VOLUME (m3) * Isolation murs et plafond 12°C Modèle 30 Modèle 48 32°C ext. entre 60 et 80 mm de Polyuréthane * Insulation of the ceiling and the walls between 60 and 80 mm of PU for a device installed in the wall of the cellar ** under the following conditions: 12°C in the cellar / 32°C outside.
Technical data R290 T cave= +12°C - Text= 32°C SPC EVX2 780** 1100** Cooling capacity 230V / 50Hz 230V / 50Hz Power supply 365W / 2.3A 508W / 3.2A W / A 4 / 4.4 5 / 4.4 Intensité Max Mode Froid / Chaud Cellar side airflow m3/h m3/h...
Page 6
Dimensions models male IN mounting cellar exterior Condenser Drain Cellar interior OUT mounting IN/OUT mounting 1021 1170...
Page 7
Configuration Mounting IN duct side condenser Installation through the wall - The air conditioner must be installed in an open place. - In order to have a perfect diffusion of the air, it is advised to install the air conditioner in height. - Any natural and mechanical ventilation is to be avoided in the cellar.
Page 8
Configuration Mounting IN duct side condenser Setup 4, Setup 5, Angle outside the cellar Angle outside the cellar Configuration Mounting IN duct side condenser Side Outside...
Page 9
Configuration Mounting OUT duct side evaporator Cellar side Configuration Mounting IN - OUT ducting on the evaporator / condenser side Side Outside Cellar side...
Page 10
After having chosen the installation configuration of your monobloc, you will need to install the front panel in black plexiglass according to your configuration, in IN - OUT configuration it will be of no use to you, in this case keep it aside.
Page 11
KLPWSECU kit (vintage option). On vintage models you will need to connect a klpwsecu kit, on the Out and IN-OUT configurations it will first be necessary to put the connector E and the tube D on the device before fixing the duct frontage. (Refer to page 15 for the cutting of the holes for the passage of the supply tube).
Page 12
DUCTED FACADE INSTALLATION Présentation. ø 200 mm ø 160 mm ø 200 mm ø 160 mm blowing / Blowing Ø 160 or/or 200mm suction / suction Ø 160 or/or 200mm...
Page 13
DUCTED FACADE INSTALLATION IN mouting Preparation of the ducted facade on the condenser side Cutout for passage of the cable from clipping in the recess...
Page 14
IN Mounting Duct compatibility -Reduce the length of the duct -Reduce the number of elbows installed ø160mm duct on AIR CONDENSER Duct total length MPC 30 IN ø200mm duct on AIR CONDENSER Duct total length MPC 30 IN ø160mm duct on AIR CONDENSER Duct total length MPC 48 IN ø200mm duct on AIR CONDENSER...
Page 15
DUCTED FACADE INSTALLATION OUT Mouting: Preparation of the ducted facade on the evaporator side Probe extension Connect the RJ 12 socket (1) coming out of the monobloc to the female//female coupler (2). Connect the supplied 6M RJ12 extension (3) from the female//female coupler (2) to the probe.
Page 16
DUCTED FACADE INSTALLATION MAXIMUM connection length for the Evaporator probe: 6 m To avoid any problem with the operation of the air conditioner, it is essen- tial to bring the sensor back into the atmosphere of the cellar when moun- ting OUT.
Page 17
Montage OUT Value of the fan speed Duct total length m PC 0 O T Duct total length m PC 0 O T Duct total length m PC 4 O T PC 4 O T...
Wiring diagram The card is equipped with an auxiliary contact COM-NO-NC 2 functions can be associated with the auxiliary contact: - ECL lighting function 16 A max - Alarm reporting function The card is basically programmed for lighting function. Lighting function: To turn on the lighting, refer to the RSF2 Commissioning &...
Maintenance WARNING refrigerants.. Condenser Side Maintenance - Restore power Maintenance on the evaporator side (int. cellar) Evaporator side Condenser side...
Page 21
231/233 Rue de la Prairie F-73420 Voglans Site web : www.friax.fr info @friax.fr Boite mail : Découvrez notre gamme de rangement pour la cave ! ® VisioRack L'agencement du vin www.visiorack.com...