Page 1
Les caractéristiques données dans cette fiche technique peuvent évoluer sans avis préalable, avec les améliorations que "FRIAX Industrie" entend toujours apporter à sa production. GB-NT-SPCRSF-0120 "FRIAX industrie", in a constant endeavour to improve its products reserves the right to change any information contained in this leaflet without prior warning...
Page 2
Unplugging or disconnecting the power turn off the crankcase heater. FRIAX industry can’t be held res- ponsible for improper handling of its products.
Genesis & Vintage Remote control Power: 2 x 1.5V (AAA) provided The remote control can be installed in another room as the cellar. Its maximum range is 100m in open field. This distance can be reduced from the thickness of the walls and the loca on of the cellar.
Page 4
Genesis & Vintage Display 7 8 9 Navigation key Navigation key Validation key Start key Menu key -Red : heating mode Stand by -Green : cooling mode Return Stop -Flashing red : Alarm Radio frequency signal Configuration type Temperature or humidity indicator (option) Key lock indicator Battery charge level indicator Crankcase heater indicator...
Page 5
Genesis & Vintage Step I First Start Be careful before this step Make sure that all the electrical elements, wires, probes etc ... are well connected. Without this, the functions of the probes and motors would not be taken into account. Step 1a- Pair the controller with the remote control Manipula ons Views...
Page 6
Step II & III Genesis & Vintage Step II - Star ng Func ons Manipula ons Displays Remarks The unit starts. Start the unit with the Press remote control If the icons for 2 seconds fixed or flashing are flashing the unit is in standby mode.
Page 7
Genesis & Vintage Step IV Step IV - Set the cellar fans speed Remarks Access to Parameters Screens Manipulations menu Even if the screen is blank Press Login with Se ng the See below the value Change the value with for 6 seconds speed evapora- set according to the...
Page 8
Genesis & Vintage Step IV Op miza on of the fan Speed Accordind to the cellar configuration, it will be more accurate to set the airflow (speed fan) with an anemometer. You will find the air flow value in the table «technical data» of the installation manual of your air conditioner.
Page 9
Genesis & Vintage Basic Func ons func ons Handling Views Remarks The display alternately Display the tempera- shows the value of the Press ture or humidity of the temperature and humidity cellar (Only available on Vintage model) Put the fan in the cellar Press The fan switches to low in silent mode...
Page 10
Genesis & Vintage User Menu Remarks Access to Parameters Screens Manipulations menu Login with Change the value with Switches from 12 h Se ng the me AM / PM display on display. 12 or 24 hours confirm with Login with Even if the screen Change the value with is blank Press...
Page 11
Genesis & Vintage User Menu Remarks Access to Parameters Screens Manipulations menu This parameter is Login with set to 0 at the factory. It may be modified only in Change the value with the case where Calibra ng the there would be a temperature difference sensor...
Page 12
Alarms Genesis & Vintage Two Types of errors may appear on the wireless control Alarm type 1 : Steady green LED and red LED flashes on the front panel. A warning message appears on the wireless control and bu on flashes.
Air condi oner Friax is designed to works in an environment without ven la on. check the insula on of door frames, check there is no natural air inlet there.
Page 14
Reset Genesis & Vintage How to reset to factory configura on of the remote Remove one of the battery and reset it. First message displayed inform you of the remote control version Reset version 2.1 & 3.2 Enter the code 2013 with Press Press...
Genesis & Vintage Maintenance Maintenance of your air condi oner The following maintenance opera ons repeated every 6 months will allow your SPC air condi oner to maintain its performance in op mal ways to ensure its longevity and that of your wines. WARNING Before all maintenance opera ons, cut off...
Page 16
Genesis & Vintage 231/233 Rue de la Prairie F-73420 Voglans Site web :www.friax.fr Boite mail : info @friax.fr Découvrez notre gamme de rangement pour la cave ! ® VisioRack L'agencement du vin www.visiorack.com...