Download Print this page

Advertisement

Quick Links

AURATON Aquarius SET
User manual ver. 20220216
The document presents collected information on safety, assembly and use of AURATON Aquarius SET.
Wireless controller of a circulation pump in the DHW system
activated by a motion sensor
(set)
Congratulations on your purchase of a modern set – a wireless DHW circulation pump controller.
activated by a motion sensor AURATON Aquarius SET.
Wireless controller of a circulation pump in the DHW system activated by the AURATON Aquarius SET
motion sensor is designed to support the "intelligent circulation" of the DHW circuit. The circulation
pump connected to the AURATON Aquarius CR output is activated only when the AURATON Aquarius
PIR motion sensor detects the activity of the domestic hot water users in the room (e.g. in the
bathroom). Additionally, AURATON Aquarius CR activates the circulating pump only for a pre-set time
(factory set to 2 minutes).
The lithium battery (CR 123A 3V) used allows for many years of uninterrupted
operation of the motion sensor.

Advertisement

loading
Need help?

Need help?

Do you have a question about the Aquarius SET and is the answer not in the manual?

Questions and answers

Summary of Contents for AURATON Aquarius SET

  • Page 1 Congratulations on your purchase of a modern set – a wireless DHW circulation pump controller. activated by a motion sensor AURATON Aquarius SET. Wireless controller of a circulation pump in the DHW system activated by the AURATON Aquarius SET motion sensor is designed to support the “intelligent circulation” of the DHW circuit. The circulation pump connected to the AURATON Aquarius CR output is activated only when the AURATON Aquarius PIR motion sensor detects the activity of the domestic hot water users in the room (e.g.
  • Page 2 Work under load up to 16 A/10 A The AURATON Aquarius CR receiver is equipped with a relay that can operate under a load of up to 16 A/10 A. The low-spark technology of switching the mains voltage causes minimal wear of the relay contacts.
  • Page 3 Removing the sensor’s rear cover NOTE: The AURATON Aquarius PIR motion sensor and the AURATON Aquarius CR pump controller purchased as a set are factory-paired with each other and do not require the pairing procedure. Mounting the AUARTON Aquarius PIR to a wall NOTE: Before attaching the motion sensor to a wall, it must first be paired with a previously...
  • Page 4 2.7 mm instead of 5 mm and put the screws directly into the wood. Description of the circulation pump controller in the AURATON Aquarius CR domestic hot water system (receiver) Aquarius CR (receiver) works with Aquarius PIR wireless motion sensors. The receiver is mounted next...
  • Page 5 Detachable power connector terminals 230 V AC Mounting hole Power button Power supply diode Button to unpair devices and setting DHW pump pause time Diode indicating that the actuator device is switched on Diode indicating that the actuator device has been switched off Button to pair devices with the receiver and setting DHW pump operation time Control connectors Legend –...
  • Page 6 NOTE: while installing the AURATON Aquarius CR receiver, the power supply should be turned off. It is recommended to entrust the installation of the receiver to a specialist.
  • Page 7 AURATON Aquarius CR. Wires can be routed from the bottom of AURATON Aquarius CR after holes are punched in the mounting plug or from the back of AURATON Aquarius CR if the wires are pulled out of the wall. To connect from the back, break the plug.
  • Page 8 Connect the heating or air-conditioning device to the clips of the AURATON Aquarius CR control connector. Follow the service manual of the heating or air-conditioning device. COM (common) and NO (normally open circuit) clips are most commonly used. Connect the power supply wires to the clips of the power supply connector of the AURATON...
  • Page 9 Wire mounting bracket. Once the wires are connected, secure them with the “wire mounting bracket” and screw the cover back onto the AURATON Aquarius CR receiver. Mounting AURATON Aquarius CR onto a wall To fix AURATON Aquarius CR to a wall:...
  • Page 10 Mark the location of the holes for the mounting screws on the wall. Drill holes with diameters of the attached plugs (5 mm) where marked. Insert wall plugs into the drilled holes. Screw the AURATON Aquarius CR receiver to the wall with the screws, so that the device is fixed securely. NOTE: If the wall is wooden, there is no need to use wall plugs.
  • Page 11 0.5 m above the ground). These types of sensors are usually ceiling-mounted at a height of about 2.5 Pairing the AURATON Aquarius PIR with the AURATON Aquarius CR NOTE: The AURATON Aquarius PIR sold together with the AURATON Aquarius CR is already paired. Devices purchased separately require “pairing”.
  • Page 12 RESET of the Aquarius CR (see “RESET – return to factory settings”) and try pairing the devices again. NOTE: Once paired, the device cannot be paired again with the AURATON Aquarius CR as it is already stored in memory. NOTE: The AURATON Aquarius CR allows pairing of up to 20 AURATON Aquarius PIR motion sensors.
  • Page 13 If there is a pairing error, please repeat steps 1 and 2. In the event of further errors, unpair all devices via a RESET of the AURATON Aquarius CR (see “RESET – return to factory settings”) and try pairing the devices again.
  • Page 14 From 1 to 5 minutes. Pressing a sixth time goes back to 1 minute again. At the end the AURATON Aquarius CR will show the domestic hot water pump operating time with the appropriate number of green flashes and the interval time of the domestic hot water pump with the appropriate number of red flashes.
  • Page 15: Additional Information

    LED diodes). In the event of a power failure, AURATON Aquarius CR will switch off. After power is restored, the heating device will automatically switch on, and AURATON Aquarius CR will wait for a signal from the paired AURATON thermostat (transmitter) no longer than 5 minutes after power is restored.
  • Page 16: Cleaning And Maintenance

    Diagram of connection of the DHW circulation pump from AURATON Aquarius CR 1 – DHW pump Cleaning and maintenance The outside part the device should be cleaned with a dry cloth. Do not use solvents (such as benzene, thinner or alcohol).
  • Page 17: Technical Specifications

    – Operation range: approx. 30 m; in open space – up to 300 m Radio signal strength: Up to 11 dBm Receiver Category AURATON Aquarius CR: 2 Contact and address of the manufacturer Lars ul. Świerkowa 14 64-320 Niepruszewo Polska...
  • Page 18 Disposing of the devices The devices are marked with the crossed waste bin symbol. According to European Directive no. 2012/19/UE and the Act concerning used up electric and electronic equipment, such a marking indicates that this equipment may not be placed with other household generated waste.