Page 1
Apus R collecting information about the current room temperature and the setpoint temperature. In one room, there can be any number of radiators with AURATON Apus heads, or on the underfloor heating manifold there can be any number of circuits to a given room, but they should all be paired with the same AURATON Apus R.
Page 2
In order to mount AURATON Apus on the radiator or underfloor heating manifold with the M30x1.5 insert, the following steps should be carried out: Screw face bushing A (1) on the insert; the face bushing is included in the AURATON Apus set (to the stop).
Page 3
Remove the battery cover (2) of AURATON Apus using a flat screwdriver. Install two AAA batteries in AURATON Apus paying attention to polarity. The head pin will move to the extreme open position, making it easy to mount the AURATON Apus on the face bushing.
Page 4
Move the safety ring (3) to the “unlocked” position. Slide AURATON Apus (4) onto face bushing A (5) to the stop.
Page 5
Close the battery cover (2) of the Auraton Apus. Radiator with the Danfoss RA-N insert In order to mount AURATON Apus on a radiator with the Danfoss RA-N insert, it is necessary to: Place 2 halves of face bushing B (1) on the Danfoss RA-N insert...
Radiator with M30x1.5″ insert Pairing devices For proper operation of the AURATON Apus head, it is required to pair it with the AURATON Apus R regulator. The pairing process is as follows: Restore AURATON Apus to factory settings (see section “Restoring the head to factory settings”) In AURATON Apus R press simultaneously for more than 3 seconds.
Page 7
It is not signalled, but is necessary for the proper operation of the set. If radio communication is disturbed, e.g. due to depletion of the battery in AURATON Apus R or during its replacement, AURATON Apus will signal a lack of communication after 6 minutes by lighting the LED every 8[s].
AURATON Apus with the valve. Installation instructions AURATON Apus R should be placed in the room where AURATON Apus with a radiator is located or the room to which appropriate underfloor heating circuits are connected. It should not be placed near a radiator, by a door or in a sunny location.
8 minutes. In order to switch off the sound signalling for 24 h, press any key on the AURATON Apus R paired with this AURATON Apus, or lift the AURATON Apus flap for 2[s], and reinstall it.
The user shall return it to a collection point for electrical and electronic waste. Hereby, LARS Andrzej Szymanski declares that the radio equipment type AURATON Apus is in compliance with Directive 2014/53/EU and 2011/65/EU. The full text of the EU declaration of...
Page 11
Contact and address of the manufacturer: Lars ul. Świerkowa 14 64-320 Niepruszewo Polska www.auraton.pl Download User manual Declaration of conformity...
Need help?
Do you have a question about the Apus and is the answer not in the manual?
Questions and answers