The document presents collected information on safety, assembly and use of AURATON Roller Shutter.
Safety information
Installation should be carried out by qualified electricians in accordance with the national
P
rules of electrical works. Read this manual before installing the controller. For safety
reasons, do not install the controller without a housing or with a damaged housing as it may
cause a risk of electric shock.
WARNING!
Q
Prior to installation, make sure that there is no dangerous voltage in the connecting cables.
Description of the controller
AURATON Roller Shutter is used to control the equipment with a rotation drive and possible change of

Advertisement

loading
Need help?

Need help?

Do you have a question about the Roller Shutter and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AURATON Roller Shutter

  • Page 1 WARNING! Prior to installation, make sure that there is no dangerous voltage in the connecting cables. Description of the controller AURATON Roller Shutter is used to control the equipment with a rotation drive and possible change of...
  • Page 2 The AURATON Roller Shutter is equipped with the LED indicating the current operation status and the button enabling addition or removal of the device to/ from the AURATON Smart system (Fig. 1). AURATON Roller Shutter is designed for indoor use only, and should be mounted in a junction box.
  • Page 3: Controller Dimensions

    Controller dimensions Controller functions The controller has been designed and manufactured in Poland in accordance with the applicable standards. The controller may be installed in junction box of a minimum depth of 60 mm, which meets national standards.
  • Page 4: Connection To Mains

    Connection to mains AURATON Roller Shutter may be connected only to 230 V AC mains. Electric system should be protected by overcurrent circuit breaker rated to the maximum withstand current of 10 A, meeting national standards.
  • Page 5 WARNING! Improper connection may cause controller damage and create a risk of electric shock. Connection of power supply to the AURATON Roller Shutter controller for roller shutters: Double switch...
  • Page 6 60-240 VAC voltage: Explanations to the diagram: (N) neutral conductor terminal (L) phase conductor terminal (O1) motor input – direction A (O2) wejście silnika – kierunek B (l1) switch terminal – direction A (l2) switch terminal – direction B motor wall switch Single switch...
  • Page 7 60-240 VAC voltage: Explanations to the diagram: (N) neutral conductor terminal (L) phase conductor terminal (O1) motor input – direction A (O2) wejście silnika – kierunek B (l1) switch terminal – direction A (l2) switch terminal – direction B motor wall switch...
  • Page 8: Basic Calibration

    Press and hold down the wall switch button for 5 s. The roller shutter moves to the outermost positions for calibration. As a full movement in both directions should be performed, usually three passes are required; first pass determines the start position.
  • Page 10: Pairing Of Devices

    Fig. 5.1. It means the working equipment is not paired with the AURATON Smart system. If the LED is flashing as shown in Fig. 5.3 or Fig. 5.4, first disconnect the device from the system.
  • Page 12 Status: The device is not connected to the system. LED: Status: The device is in pairing mode. LED: Status: The device is connected to the system and properly functioning. LED: Status: The device cannot communicate with the AURATON system – check the range. LED:...
  • Page 13: Reset To Default Settings

    Control Local control AURATON Roller Shutter may be locally controlled using both single and double mono or bi-stable switches. The difference in control between mono- and bi-stable switches results from their design. Bistable switches hold their state after click, while monostable switches, also called “the bells”, turns on the phase only for a short time.
  • Page 14 movement in direction B (switch clicked) stop (moment of arrival at the end position) movement in direction A (click) Single switch – bi-stable Similarly to the control with use of a monostable switch, control of operation direction follows alternately. A “click” starts the movement, “unclick” stops it, next “click” starts movement in opposite direction.
  • Page 15 (switch pressed) Double switch – monostable The control is performed according to the clicked switch key. Click the “A key” to start movement in “A” direction and the “B key” – in the “B” direction. Press any key during movement to stop the motor. An example of consecutive “clicking”...
  • Page 16 (moment of arrival at the end position) movement in direction A (switch A) Control through the AURATON Smart application AURATON Smart application may be used to control the level of opening/closing roller shutters upon previous calibration. Figure 7. Entry of power supply tariff:...
  • Page 19 Figure 8. Control of equipment connected to AURATON Smart system:...
  • Page 24 Device symbol After adding the AURATON Roller Shutter unit and assigning it to the appropriate room, a symbol of the device concerned is shown. The current position in % is shown. Click it to control its full opening/closing stroke. Each subsequent click changes the direction.
  • Page 29 Internal menu (1) Click and hold down the symbol to display internal menu of the equipment. It contains the current position of the roller shutters, information about the current and total power consumption and slider to set the target position.
  • Page 34 Internal menu (2) Once the slider has moved to the desired position, the equipment starts to move in the appropriate direction. Respective value appears in the current power consumption box if the equipment is in motion.
  • Page 39 0 W. Peripheral devices software update The AURATON Smart system enables remote update of peripheral devices software. The update is performed over-the-air (OTA) and is always followed by rebooting the respective device. If update expands the device with functions, which are not desired, previous software version may be restored manually.
  • Page 40 A red marker indicates update is available for the respective device. To download the update click and hold down respective icon for a while to move to the control screen.
  • Page 41 “Follow” the marker further and click the device settings icon. Click “Upgrade Software” in next window.
  • Page 42 Click “Update”. Update may take several minutes and during that time the AURATON Pulse control unit does not respond to the instructions sent by the application. Once the update has been completed, the red marker should disappear; otherwise repeat the foregoing steps again.
  • Page 43 Status: Device in OTA update mode. Dioda: Status: Restoring the previous software version. LED: Status: Software upload in progress (LED lights continuously until upload is completed) Dioda: Status: No software to upload (2 blinks). LED: Status: Software uploaded successfully (3 blinks). LED: Status: Software upload failed, incorrect version in the memory or memory communication issue (3 blinks).
  • Page 44: Restoring The Previous Software Version

    Status: Unexpected error during a software change that prevents proper device start-up. Service contact required. LED: Restoring the previous software version Upon successfully completed or failed update (Fig.9.4), the previous software version may be restored. There are two ways to perform it. With power disconnected: Press the button on the device housing, turn on the power –...
  • Page 45: Technical Specifications

    – by OTA Control method: local – using buttons Maximum number of paired devices: Cooperation with internet control unit: AURATON Pulse in a typical house, with standard wall Operation range: structures – up to 30 m outdoors – up to 50 m...
  • Page 46 The user shall return it to a collection point for electrical and electronic waste. Hereby, LARS Andrzej Szymanski declares that the radio equipment type AURATON Roller Shutter is in compliance with Directive 2014/53/EU and 2011/65/EU. The full text of the EU declaration of conformity is available below in the download area.