Graco 287023 Operation And Parts
Graco 287023 Operation And Parts

Graco 287023 Operation And Parts

Pole gun with cleanshot shut-off valve and contractor in-line valve
Hide thumbs Also See for 287023:

Advertisement

Quick Links

Operation and Parts
Pole Gun with CleanShot™ Shut-off
Valve and Contractor® In-line Valve
For the application of architectural paints and coatings. For professional use only.
3600 psi (24.8 MPa, 248 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Refer to your sprayer instruction
manual for Pressure Relief, priming, and
spray instructions. Save these instructions.
Important Medical Information
Read the medical alert card provided with
the gun. It contains injection injury treatment
information for a doctor. Keep it with you
when operating the equipment.
Model 287023, Series A (North America)
With 3-ft (0.9 m) extension (244163)
Model 287024, Series A (North America)
With 6-ft (1.8 m) extension (244164)
Model 244161, Series A (North America)
Contractor In-line Valve
Model 287026, Series A (Europe)
With 3-ft (0.9 m) extension (244163)
Model 287027, Series A (Europe)
With 6-ft (1.8 m) extension (244164)
Model 244364, Series A (Europe)
Contractor In-line Valve
Model 244368, Series A (Asia)
With 3-ft (0.9 m) extension (244163)
Model 244369, Series A (Asia)
With 6-ft (1.8 m) extension (244164)
Model 287028, Series A (Asia)
With 3-ft (0.9 m) extension (244163)
Model 287029, Series A (Asia)
With 6-ft (1.8 m) extension (244164)
Model 244365, Series A (Asia)
Contractor In-line Valve Model
309237J
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 287023 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Graco 287023

  • Page 1 It contains injection injury treatment information for a doctor. Keep it with you when operating the equipment. Model 287023, Series A (North America) Model 244368, Series A (Asia) With 3-ft (0.9 m) extension (244163) With 3-ft (0.9 m) extension (244163)
  • Page 2: Table Of Contents

    Flush the CleanShot Shut-off Valve ... 9 Graco Standard Warranty....19 Flush the Contractor In-Line Valve .
  • Page 3: General Warnings

    General Warnings General Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning, labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 4 General Warnings WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or solvent flowing through the equipment can cause static sparking. To help prevent fire and explosion. • Use equipment only in well-ventilated area.
  • Page 5 General Warnings WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read Safety Data Sheets (SDSs) to know the specific hazards of the fluids you are using. •...
  • Page 6: Setup

    Setup Setup 8. Open the dump drain valve on the sprayer to help relieve fluid pressure in the pump, hose, and pole gun. Have a container ready to catch drainage. If you suspect that the spray tip or hose is completely To avoid serious injury from skin injection, do not put clogged or that pressure has not been fully relieved your hand in front of the spray tip.
  • Page 7: Install Tip And Tip Guard

    Setup Install Tip and Tip Guard 5. Install guard (25) over the end of the gun (1). Hand tighten retaining nut. Assemble Pole Gun 1. Connect to CleanShot shut-off valve to the 3-ft or To avoid serious injury from skin injection do not put 6-ft extension.
  • Page 8: Operation

    Operation Operation Changing Spray Pattern Orientation To reduce the risk of a fluid injection injury, do not operate the pole gun with the tip guard or trigger guard removed. To avoid serious injury from skin injection do not put Spraying your hand in front of the spray tip.
  • Page 9: Clearing A Clogged Spray Tip

    3. If flushing with water, flush last with a rust inhibitor eyes or on skin, follow these precautions before you or Graco Pump Armor to protect the system from remove, clean, or change a spray tip or tip guard. corrosion.
  • Page 10: Maintenance

    Maintenance Maintenance Cleaning the Filter 2. Push up on the trigger guard (3) and swing it away from the trigger (2). Perform the following procedure to clean the filter 3. Unscrew the in-line valve handle (13) from the assembler (5) daily. housing (11).
  • Page 11: Repair

    Repair Repair Changing the Needle 3. Squeeze the trigger while installing gasket (B) and seat (A). NOTE: Needle (C), seat (A), gasket (B), and locknut (D) 4. If gun handle (13) was removed, hand-tighten into must be replaced together. They are included in repair fluid housing (11).
  • Page 12: Replacing The In-Line Valve Swivel

    Repair Replacing the In-Line Valve Swivel Disassembly 1. Perform the Pressure Relief Procedure, page 6. 2. Push up on the trigger guard (3) and rotate the trigger guard away from the trigger (2). 3. Unscrew the gun handle (13) from housing (11). Remove filter (5) and clean it in a compatible solvent.
  • Page 13: Changing The Needle

    Repair Changing the Needle Disassembly (upper module) 1. Perform the Pressure Relief Procedure, page 6. NOTE: The components included in the CleanShot Valve Repair Kit 244162 are packaged as two separate 2. Remove the tip guard (not shown). modules; individual pieces cannot be ordered separately.
  • Page 14: Replace The Cleanshot Swivel

    Repair Replace the Cleanshot Swivel NOTE: Check the swivel for leaks. The o-ring can be damaged if they are not properly seated when the stud and swivel are pressed together (see step 3). Disassembly 1. Perform the Pressure Relief Procedure, page 6. 2.
  • Page 15: Parts

    Parts Parts Model 287030 Cleanshot Shut-off Valve Model 244161 Contractor In-Line Valve (North America) Model 244364 Contractor In-Line Valve (Europe) Model 244365 Contractor In-Line Valve (Asia) Included in kits Page 16 309237J...
  • Page 16 Parts Cleanshot Repair Kit 244162 (31) Swivel Repair Kit 244363 (35) † Valve Body Repair Kit 245687 (36) *† * 36 Valve Body Kit must be purchased separately † Series A and B 309237J...
  • Page 17: Parts List

    Parts Parts List Model 287030 Cleanshot Shut-off Valve Model 244161 Contractor In-Line Valve (North America) Model 244364 Contractor In-Line Valve (Europe) Model 244365 Contractor In-Line Valve (Asia) Part Part Description Description Qty. Qty. - - - - - SEAT, valve 218070 NEEDLE-DIFFUSER/SEAT KIT - - - - - GASKET 244193 TRIGGER, gun, in-line...
  • Page 18: Technical Specifications

    UHMWPE aluminum, tungsten carbide, stainless steel, Wetted parts PTFE, brass Maximum material temperature 120° F 50° C Weight Model 287023, 287026, 287028, 244368 2.76 lb 1.03 kg Model 287024, 287027, 287029, 244369 3.5 lb 1.3 kg Sound data* Sound pressure level...
  • Page 19: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
  • Page 20 Original instructions. This manual contains English. MM 309237 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA Copyright 2021, Graco Inc. All Graco manufacturing locations are registered to ISO 9001. www.graco.com...