Graco CleanShot 287727 Instructions Manual
Graco CleanShot 287727 Instructions Manual

Graco CleanShot 287727 Instructions Manual

Low overspray valve

Advertisement

Quick Links

Instructions
Low Overspray
CleanShot
Model 287727
For use on the Graco Low Overspray Kit.
®
Includes RAC
5 321 SwitchTip
3600 psi (25 MPa, 248 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441
Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001
Valve
and RAC 5 HandTite
Guard.
311103C

Advertisement

Table of Contents
loading

Summary of Contents for Graco CleanShot 287727

  • Page 1 3600 psi (25 MPa, 248 bar) Maximum Working Pressure Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 Warnings Warnings The following general warnings are related to the safe setup, use, grounding, maintenance and repair of this equip- ment. In the text of this manual, the exclamation point symbol alerts you to a warning and the hazard symbol refers to specific risks.
  • Page 3 Check equipment daily. Repair or replace worn or damaged parts immediately. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. •...
  • Page 4: Pressure Relief Procedure

    Pressure Relief Procedure Pressure Relief Procedure 6. Open all fluid drain valves in the system, having a WARNING waste container ready to catch drainage. Leave drain valve(s) open until you are ready to spray again. 7. If you suspect the spray tip or hose is clogged or Follow Pressure Relief Procedure when you stop that pressure has not been fully relieved after follow- spraying and before cleaning, checking, servicing, or...
  • Page 5: Installation

    Installation Installation WARNING CAUTION To reduce the risk of serious bodily injury from fluid To avoid damage to the o-ring in the swivel: injection or splashing in the eyes or on the skin, stop • Relieve fluid pressure before rotating the swivel. using the nozzle immediately if it starts to leak or can- •...
  • Page 6 Parts Parts CleanShot Repair Kit 244162 (31) Swivel Repair Kit 244363 (35)† Valve Body Kit 245687 (36)*† * 36 Valve Body Kit must be purchased separately † Series A and B 311103C...
  • Page 7: Parts List

    Parts List Parts List Ref. Part No. Description Qty. 244162 KIT, CleanShot, repair includes 31a-31k SEAT, valve GASKET RETAINER, ball DAMPENER, spring SPRING, compression GUIDE, spring SEAL, u-cup PACKING, o-ring RETAINER, u-cup CAP, end, u-cup KNOB, valve 15H622 GASKET, non-metallic 244363 KIT, swivel repair 244663 SWIVEL, inlet assembly 120189 NUT, cap...
  • Page 8: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.