Table 1-8. System Messages (continued)
Message
Attempting to update
Remote Configuration.
Please wait...
BIOS Update Attempt
Failed!
Caution! NVRAM_CLR jumper
is installed on system
board.
Diskette drive n seek
failure
Diskette read failure
Diskette subsystem reset
failed
Drive not ready
Error: Memory failure
detected. Memory size
reduced. Replace the
faulty DIMM as soon as
possible.
Remote configuration
update attempt failed
Fatal error caused a
system reset: Please check
the system event log for
details.
Causes
Remote Configuration request has
been detected and is being processed.
Remote BIOS update attempt failed. Retry the BIOS update. If problem
NVRAM_CLR jumper is installed.
CMOS has been cleared.
Incorrect configuration settings in the
System Setup program.
Faulty or improperly installed diskette
drive.
Loose diskette drive interface cable, or
loose power cable.
Faulty or improperly inserted diskette. Replace the diskette. If the problem
Faulty or improperly installed
diskette.
Diskette missing from or improperly
inserted in diskette drive.
Faulty or improperly seated memory
module(s).
System unable to process Remote
Configuration request.
Fatal system error.
Corrective Actions
Wait until the process is complete.
persists, see "Getting Help" on page 129.
Remove the NVRAM_CLR jumper. See
Figure 6-1 for jumper locations.
Run the System Setup program to
correct the settings. See "Using the
System Setup Program" on page 31.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Reseat diskette drive interface cable, or
power cable. See "Troubleshooting a
Diskette Drive" on page 108.
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
Replace the diskette. If the problem
persists, see "Troubleshooting a Diskette
Drive" on page 108.
See "Troubleshooting System Memory"
on page 106.
Retry Remote Configuration.
Check the system event log for the
specific cause, then see the appropriate
section in"Troubleshooting Your System"
on page 97.
About Your System