Table 1-7. LCD Status Messages
Line 1
Line 2
Message
Message
N/A
SYSTEM NAME
E1000
FAILSAFE, Call
Support
E1A14
SAS Cable A
E1A15
SAS Cable B
E1114
Temp Ambient
E1210
CMOS Batt
E1211
ROMB Batt
E12 nn
XX PwrGd
E1229
CPU # VCORE
E122A
CPU # VTT
Causes
A 62-character string that can be
defined by the user in the System
Setup program.
The SYSTEM NAME displays
under the following conditions:
• The system is powered on.
• The power is off and active
POST errors are displayed.
SAS cable A is unseated, missing,
or bad.
SAS cable B is unseated, missing,
or bad.
Ambient system temperature is
out of acceptable range.
CMOS battery is missing, or the
voltage is out of acceptable range.
RAID battery is either missing,
bad, or unable to recharge due to
thermal issues.
Specified voltage regulator has
failed.
Processor # VCORE voltage
regulator has failed.
Processor # VTT voltage has
exceeded the allowable voltage
range
Corrective Actions
This message is for information
only.
You can change the system string
in the System Setup program. See
"Using the System Setup
Program" on page 31.
See "Getting Help" on page 129.
Check the cable connection to
the SAS backplane. See "SAS
Backplane Board Connectors" on
page 127.
Check the cable connection to
the SAS backplane. See "SAS
Backplane Board Connectors" on
page 127.
See "Troubleshooting System
Cooling Problems" on page 105.
See "Troubleshooting the System
Battery" on page 104.
Reseat the RAID battery. See
"Installing the SAS RAID
Controller Card Battery" on
page 76, and "Troubleshooting
System Cooling Problems" on
page 105.
See "Getting Help" on page 129.
See "Getting Help" on page 129.
See "Getting Help" on page 129.
About Your System
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge 6950

Table of Contents