Page 2
Smooth input and output of 3D digital data are essential to increasing work efficiency during the design, manufacturing, and inspection processes. By introducing the VIVID 9i, Konica Minolta has accelerated the revolution in manufacturing - a Mass production sector committed to the use of digital processing...
Page 3
ISO 9000 requirements. ∗On request, Konica Minolta can provide a test report for each 9i unit. This test report is created by evaluating the measurement accuracy for all 3 lenses of each 9i using our Reference 3D Chart, an artifact traceable to national standards, and thus can be used as documentation for conformance with ISO requirements.
Page 4
Photogrammetry System PSC-1 optional VIVID 9i captures large parts (> 1 meter) easily. When PSC-1 is used with the 9i, the combination enables the user to capture both high-detail and large parts. In the past, the alignment of multiple scans was error prone, making it hard to achieve high-detail and high accuracy on large parts.
Page 5
Example of procedure for CAD data creation - Creation of a CAD Model of an automot Measured data (polygon) Creating curves Creating NUR � Engine valve cover Measurement, alignment, merging, hole filling, and cleaning Manual curve creation Creates a NURBS p Unnecessary when the automatic surface creation function is used Various analysis software/Rapid prototyping Example of measured data...
The application examples shown here use Polygon Editing Tool Ver.2.0 and optional Revers software. tive aluminum casting - Trimmed NURBS surfaces High-continuity surface data IGES patch matching the curve boundaries Create geometrically shaped surfaces such as cones and planes. Example of continuous surface evaluation using environment mapping Trim the data with these surfaces.
Page 7
High-accuracy measurement of even large parts Galvanometer - driven mirror The VIVID 9i can be combined with PSC-1 , Konica Minolta’s optional photogrammetry system. The combination of the VIVID 9i <Measurement principle> and PSC-1provides for fast and accurate measurement and data The VIVID 9i is based on the principal of laser triangulation.
Page 8
MIDDLE 42 to 1100 mm WIDE 66 to 1750 mm ±0.05 mm (Using TELE lens at distance of 0.6 m, with Field Calibration System, Konica Minolta’s standard, at 20°C) Accuracy (X, Y, Z) Precision (Z, σ ) 0.008 mm (Using TELE lens at distance of 0.6 m, Konica Minolta’s standard, at 20°C) Input Time (per scan) 2.5 sec...