Download Print this page

Safety Precautions - Konica Minolta CA-2000 Brochure

2d color analyzer

Advertisement

Main Specifications CA-2000
Model
Light receptor
Lens
Measurement points (Resolution)
Color indication modes
Display modes
Measurement sizes
(length per side of square) (*1)
Measurable size for typical measure-
ment distances (size/distance)
Measurement luminance range
(including ND filter use)
Measurement time (*2)
Luminance
Chromaticity
Accuracy (*3)
Luminance
Repeatability (*4)
Chromaticity
Luminance (*6)
Chromaticity (*6)
Inter-point error
(*5)
Luminance (*7)
Chromaticity (*7)
Other functions
Interface
Operating temperature and humidity range (*8)
Storage temperature and humidity range (*8)
Body only
Size
When lens and lens hood are attached
Weight
Power source
Lens Hood
Hood Cap
Standard
Calibration data DVD Included with each lens.
accessories
Other
Optional accessories
*1: Error in angle of view: 7%
*2: Measurement time differs depending on brightness of measurement object, PC performance, and data processing
contents.
The specifications above were obtained under Konica Minolta's measurement conditions shown below:
PC's CPU
: Pentium 4, 2.8GHz
Data processing : Pseudocolor display of luminance data
Resolution
: 490 x 490
Shutter speed
: Y measurement : 1/64 sec., XZ measurement : 1/32 sec.
Measurement subject brightness: S tandard/wide lens: Approx. 80 cd/m
Low-magnification macro ring and telephoto lens: Approx. 400 cd/m
High-magnification macro ring and telephoto lens: Approx. 600 cd/m
* The measurement time becomes longer when the object is dark. The longest measurement time is approx. 10 seconds with
1-time integration, approx. 27 seconds with 4-time integration, approx. 95 seconds with 16-time integration, approx. 6 minutes
and 8 seconds with 64-time integration and approx. 24 minutes and 19 seconds with 256-time integration
*3: The specifications above were obtained under Konica Minolta's measurement conditions shown below:
Measurement subject brightness: Standard/wide lens: Approx. 35 cd/m
Low-magnification macro ring and telephoto lens: Approx. 250 cd/m
High-magnification macro ring and telephoto lens: Approx. 250 cd/m
Distance: Minimum distance of each lens, Evaluation: Based on the average obtained within 10% range at the
center of the screen, Temperature: 23°C±2°C, Relative humidity: 40%±10%, Measuring light: White, reference
light source, Integration: 64 times (Normal mode)
*4: The specifications above were obtained under Konica Minolta's measurement conditions shown below:
Resolution: 196 x 196, Shutter speed: Y measurement: 1/64 sec., XZ measurement: 1/32 sec. G a i n : N o r m a l
(x1), Light intensity level: Midpoint of appropriate light intensity range, Evaluation: Based on the maximum repeat-
ability (2 ) of all pixels, Temperature: 23°C±2°C, Relative humidity: 40%±10%, Measurement subject:
White, reference light source, Integration: 64 times (Normal mode)
*5: The specifications above were obtained under Konica Minolta's measurement conditions shown below:
Measurement subject brightness: Standard/wide lens: Approx. 40 cd/m
Low-magnification macro ring and telephoto lens: Approx. 200 cd/m
High-magnification macro ring and telephoto lens: Approx. 350 cd/m
Distance: Calibration distance of each lens, Resolution: 196 x 196
Evaluation (*6) : Based on the maximum/minimum values obtained in a square at the center of the screen measur-
ing 60% of the height and width of the entire screen
(*7)
: Based on the maximum/minimum values obtained in the entire screen
Temperature: 23°C±2°C, Relative humidity: 40%±10%, Measurement subject: White, reference light source,
Integration: 64 times (Normal mode)
*8: Even if the instrument is stored within the specified usage (or storage) temperature humidity range, the displayed
value may change depending on long-period usage or storage conditions.

SAFETY PRECAUTIONS

For correct use and for your safety, be sure to read the instruction
manual before using the instrument.
Always connect the instrument to the specified power supply
voltage. Improper connection may cause a fire or electric shock.
2005 KONICA MINOLTA SENSING, INC.
CA-2000S
CA-2000W
CCD image sensor (monochrome); 2/3-inch; Effective number of pixels: 1,000 x 1,000 pixels; Equipped with XYZ filter (closely matches CIE 1931 color-
matching function) and ND filter
Interchangeable Standard, wide, and telephoto lenses; low-magnification and high-magnification macro rings (for use with telephoto lens)
980 x 980 (Available to select 490 x 490 or 196 x 196 by using Data Management Software CA-S20w)
XYZ, L v xy, L v u'v', T uv, Dominant wavelength, Excitation purity, L v contrast
Pseudocolor, RGB image, Chromaticity diagram, Spot, 3D graph, Histgram, Nonuniformity enhancement, Cross section, Color difference, Multi-screen
Standard lens
Wide lens
Approx. 98 mm or more
Approx. 145 mm or more
(depending on the distance)
(depending on the distance)
98 mm / 250 mm mm Approx.
145 mm / 200 mm Approx.
210 mm / 500 mm Approx.
410 mm / 500 mm Approx.
440 mm / 1,000 mm Approx.
850 mm / 1,000 mm Approx.
890 mm / 2,000 mm Approx.
1,770 mm/ 2,000 mm Approx.
0.1 - 100,000 cd/m
0.1 - 100,000 cd/m
2
Single : Approx. 5 sec. or more; 4-time integration: Approx. 6 sec. or more; 16-time integration: Approx. 10 sec. or more; 64-time integration : Approx. 28 sec.
or more; 256-time integration : Approx. 98 sec. or more
±3 %
±3 %
±0.005
±0.005
Temperature/humidity drift (within the operating temperature/humidity range)
Luminance: ±2% of change compared to reference temperature and relative humidity of 23°C and 40%
Chromaticity: ±0.004 of change compared to reference temperature and relative humidity of 23°C and 40%
0.5 %
0.5 %
0.001
0.001
±2 %
±2 %
±0.002
±0.002
±3 %
±3 %
±0.003
±0.003
Interval measurement, Measurement sync (Synchronization frequency selectable), Integration function, Enhanced nonuniformity display, Conversion of en-
hanced nonuniformity image into numerical values (statistical values, etc.), Pixel binning function
USB 2.0 or higher
10-30°C, Relative humidity 70% or less/No condensation
0-30°C, Relative humidity 70% or less/No condensation, 30-35°C, Relative humidity 55% or less/No condensation
160 (W) × 164 (H) × 199 (D) mm (Height including handle: 211 mm)
224 (D) mm
219 (D) mm
3.5 kg approx. (when standard lens and lens hood are attached)
AC adapter 100-240 V , 1.2 A, 50-60 Hz
CA-A68
CA-A69
CA-A71
CA-A75
Mount Cover CA-A61, AC Adapter AC-A22, AC cable, USB Cable IF-A18, Data Management Software CA-S20w
Soft Case CA-A60, Tripod CS-A3, Pan Head CS-A4, Calibration certificate
2
, Telephoto lens: Approx. 300 cd/m
, Telephoto lens: Approx. 140 cd/ m
2
, Telephoto lens: Approx. 160 cd/m
2
New Jersey, U.S.A.
European Headquarter /BENELUX Nieuwegein, Netherland
German Office (International)
German Office (Germany)
French Office
UK Office
Italian Office
Swiss Office
Nordic Office
Austrian Office
Polish Office
SE Sales Division
SE Beijing Office
Telephoto lens
Approx. 115 mm or more
(depending on the distance)
115 mm / 900 mm Approx.
275 mm / 2,000 mm Approx.
420 mm / 3,000 mm Approx.
0.5 - 100,000 cd/m
2
2
±3 %
±0.005
0.5 %
0.001
±2 %
±0.002
±3 %
±0.003
224 (D) mm
CA-A68
CA-A71
CA-S20w System Requirements
OS
Windows
XP Professional SP2 (Japanese, English, and Hangul versions)
®
Windows
®
XP Professional x 64 Edition (Japanese, English versions)
CPU
Pentium
®
4 2.8 GHz equivalent or higher
Memory
1024 MB or more
2
,
2
Hard Disk Needs free space of 80 MB at least on system drive (where OS is installed)
2
In addition, each lens needs the following free spaces for installing calibration data.
For standard lens: approx. 540 MB
For wide lens: approx. 470 MB
2
For telephoto lens: approx. 1.3 GB
,
2
2
Also to save measurement data on hard disk, additional free space is required.
(approx. 11 GB minimum for 1000 measurement data in resolution of 980 x 980)
Display
Display capable of at least 1280 x 1024 dots/65,536 colors (High color, 16 bit) .
Others
CD-ROM drive (necessary to install software)
DVD-ROM drive (necessary to install calibration data)
(A combination drive capable of reading both CD-R and DVD-R media can be used in place of the above 2 drives.)
USB port: USB ver. 2.0; Type A connector; For connecting measuring instrument
2
Excel
®
2003 (Necessary for continuous measurements using automation)
2
,
2
• Windows
,
Excel
is a registered trademark or a trademark of Microsoft Corporation in the United States and other
®
®
countries.
• Pentium
®
is a registered trademark or a trademark of Intel Corporation in the United States and other countries.
The specifications and drawings given here are
subject to change without prior notice.
- If you have any questions about specifications,
please contact your Konica Minolta representative.
- The specifications given here are subject to
change without prior notice.
888-473-2656(in USA), 201-236-4300(outside USA)
Langenhagen, Germany
München, Germany
Roissy CDG, France
Milton Keynes, United Kingdom
Milan, Italy
Dietikon, Switzerland
Västra Frölunda, Sweden
Wien, Austria
Warszawa, Poland
Shanghai, China
Beijing, China
CA-2000T
With low-magnification macro ring With high-magnification macro ring
Approx. 57mm (Fixed)
Approx. 27mm (Fixed)
57 mm / 500 mm Approx.
27 mm / 300 mm Approx.
(Fixed)
(Fixed)
0.5 - 100,000 cd/m
1 - 100,000 cd/m
2
±3 %
±3 %
±0.005
±0.005
0.5 %
0.5 %
0.001
0.001
±2 %
±2 %
±0.002
±0.002
±3 %
±3 %
±0.003
±0.003
230 (D) mm
237 (D) mm
CA-A70
201-785-2480
+31(0)30 248-1200
+31(0)30 248-1211
+49(0)511 7404-862
+49(0)511 7404-807
+49(0)89 630267-20
+49(0)89 630267-67
+33(0)1 493-82519
+33(0)1 493-84771
+44(0)1908 540-622
+44(0)1908 540-629
+39(0)23 90111
+39(0)23 9011219
+41(0)43 322-9800
+41(0)43 322-9809
+46(0)31 7099464
+46(0)31 474945
+43(0)1 87882-430
+43(0)1 87882-431
+48(0)22 56033-00
+48(0)22 56033-01
+86-021-5489 0202
+86-021-5489 0005
+86-010-8522 1551
+86-010-8522 1241
9242-4883-21
AHCDPK
Printed in Japan
4
2

Advertisement

loading

This manual is also suitable for:

Ca-2000sCa-2000wCa-2000tCa-2000swCa-2000stCa-2000wt ... Show all