HT80x V2 - User Guide INTRODUCTION The HT801 V2 and HT802 V2 are analog telephone adapters (ATAs) that allow users to connect analog phones and faxes with a VoIP (Voice over IP) system in order to create a high-quality and manageable IP telephony solutions for residential and office environments.
Page 3
Network One (1) 10/100Mbps auto-sensing Ethernet port (RJ45) Interface POWER, NET, PHONE1, POWER, NET, PHONE Indicators PHONE2 Factory Reset Button Voice, Fax, Modem Telephony Caller ID display or block, call waiting, ash, blind or attended transfer, forward, hold, do not disturb, 3-way Features conference Voice...
Universal Input: 100-240VAC, 50-60Hz. Power Output: 5.0VDC/1.0A Supply Operational: 32° – 104°F or 0º – 40ºC. Environmen Storage: 14° – 140°F or -10º – 60ºC. Humidity: 10 – 90% Non-condensing Dimensions • 100mm x 100mm x 29.5mm • 100mm x 100mm x 29.5mm and Weight •...
Page 5
HT802 V2 Package Contents Note: Check the package before installation. If you find anything missing, contact your system administrator. HT801 V2/HT802 V2 Ports Description The following figure describes the different ports on the back panel of the HT801 V2. HT801 V2 Ports The following figure describes the different ports on the back panel of the HT802 V2.
Page 6
HT802 V2 Ports Phone port for HT801 V2 Connects the analog phones/fax machines to the phone adapter using an RJ-11 Phone 1 & 2 ports for HT802 V2 telephone cable. Connects the phone adapter to your router or gateway using an Ethernet RJ45 network NET port cable.
HT801 V2/HT802 V2 LEDs Indications LED Indication Status The Power LED lights up when the HT801 V2/HT802 V2 is powered on, and it ashes Power LED when the unit is booting up The NET LED lights up when the HT801 V2/HT802 V2 is connected to a network NET LED through the Ethernet port, and it ashes when there is data being sent or received.
Page 8
Understanding HT80x V2 Interactive Voice Prompt Response Menu The HT801 V2/HT802 V2 has a built-in voice prompt menu for simple device configuration which lists actions, commands, menu choices, and descriptions. The IVR menu work with any phone connected to the HT801 V2/HT802 V2. In order to access the IVR Menu, users need to dial “***”.
Announces current Firmware Server IP Firmware Server IP Address address. Enter 12-digit new IP address. Announces current Con g Server Path Con guration Server IP Address IP address. Enter 12-digit new IP address. Upgrade protocol for rmware and con guration update. Press “9” to Upgrade Protocol toggle between TFTP/HTTP/HTTP /FTP/FTPS...
Accessing the Web UI Please follow the steps mentioned below to access the HT801 V2/HT802 V2 Web UI, : 1. Connect the computer to the same network as your HT801 V2/HT802 V2. 2. Make sure the HT801 V2/HT802 V2 is booted up. 3.
Page 11
We recommend rebooting or powering cycling the phone after applying all the changes. Changing Admin/User/Viewer Level Password To change the password for any of the access levels, please refer to the following steps: 1. Access your HT801 V2/HT802 V2 Web UI by entering its IP address on your browser. 2.
Page 12
Configuring HT80x V2 through Voice Prompts As mentioned previously, The HT80x V2 have a built-in voice prompt menu for simple device configuration. Please refer to “Understanding HT80x V2 Interactive Voice Prompt Response Menu” for more information about IVR and how to access its menu.
Register a SIP Account The HT80x V2 support Profiles that can configure two SIP servers, Please refer to the following steps in order to register your accounts via web user interface. Access your HT80x V2 web UI by entering its IP address in your favorite browser. Enter your admin password (default: found on the sticker on the back of the unit).
Rebooting HT80x V2 Remotely Press the “Reboot” button at the bottom of the configuration menu to reboot the ATA remotely. The web browser will then display a message window to confirm that reboot is underway. Wait 30 seconds to log in again CALL FEATURES The HT80x V2 support all the traditional and advanced telephony features.
Enable Call Waiting (per call). Dial “*71” +” number”. No dial tone is played in the middle Unconditional Call Forward: Dial “*72” and then the forwarding number followed by “#”. Wait for dial tone and hang up. (dial tone indicates successful forward) Cancel Unconditional Call Forward.
2. Dial an outside number (e.g. (626) 666-7890), first enter the prefix number (usually 1+ or international code) followed by the phone number. Press # or wait for 4 seconds. Check with your VoIP service provider for further details on prefix numbers.
Page 17
Call Waiting The call waiting tone (3 short beeps) indicates an incoming call, if the call waiting feature is enabled. To toggle between incoming call and current call, you need to press the “flash” button the first call is placed on hold. Press the “flash”...
Page 18
1. Pick up the handset of the connected phone (Off-hook). 2. After hearing the dial tone, input “*69”. 3. Your phone will automatically call back to the latest incoming number. All star codes (*XX) related features mentioned above are supported by ATA default settings. If your service provider provides different feature codes, please contact them for instructions.
2. Phone A dials the phone C’s number followed by # (or wait for 4 seconds). 3. If phone C answers the call, phones A and C are in conversation. Then A can press “Flash + 4” to complete transfer. 3-Way Conferencing Assume that the call is established, and phone A and B are in conversation.
Examples of valid URLs: firmware.grandstream.com fw.ipvideotalk.com/gs Firmware Upgrade procedure Please follow below steps to upgrade the firmware version of your HT80x V2: 1. Access your HT80x V2 UI by entering its IP address in your favorite browser. 2. Enter your admin password (default: found on the sticker on the back of the unit). 3.
https://www.grandstream.com/support/firmware Alternatively, users can download, for example, a free TFTP or HTTP server and conduct a local firmware upgrade. A free window version TFTP server is available for download from: https://www.solarwinds.com/products/freetools/free_tftp_server.aspx https://pjo2.github.io/tftpd64/ Instructions for local firmware upgrade via TFTP: 1. Unzip the firmware files and put all of them in the root directory of the TFTP server. 2.
Managing Automatic Upgrade When “Automatic Upgrade” is set “Check” the auto check will be done in the minute specified in this field. If set to “Every day in hour (0-23)”, Service Provider can use P193 (Auto Check Interval) to have the devices do a daily check at the hour set in this field with either Firmware Server or Config Server.
Page 23
same or different from the Firmware Server Path. A configuration parameter is associated with each particular field in the web configuration page. A parameter consists of a Capital letter P and 1 to 5 (Could be extended in the future) digit numeric numbers. i.e., P30 is associated with the “NTP Server”...
This will redirect you to a web page displaying a list of certification names and details, with their corresponding expiration dates: RESTORE FACTORY DEFAULT SETTINGS Restoring the Factory Default Settings will delete all configuration information on the phone. Please backup or print all the settings before you restore to the factory default settings.
Mapping 22 (press the “2” key twice, “A” will show on the LCD) 2222 33 (press the “3” key twice, “D” will show on the LCD) 3333 MAC Address Key Mapping For example: if the MAC address is 000b8200e395, it should be keyed in as “0002228200333395” Reset from Web Interface (Reset Type) 1.
CHANGE LOG This section documents significant changes from previous versions of the admin guide for HT80x V2. Only major new features or major document updates are listed here. Minor updates for corrections or editing are not documented here. Firmware Version 1.0.1.16 This is the initial Firmware.
Need help?
Do you have a question about the HT80 Series and is the answer not in the manual?
Questions and answers