Advertisement

BYD BATTERY-BOX PREMIUM QUICK START GUIDE
Valid for HVM-US HVM US 8.3, 11.0, 13.8, 16.6, 19.3, 22.1
Please note that this is a Quick Start Guide only, which is a shortened assistance for the installation of the BYD Battery-Box Premium
HVM-US. It does not replace the Operating Manual, which must be read and understood completely before installation. Please
download and view it on this website: www.bydbatterybox.com.
Attention: High Voltage! Improper handling can pose a risk of electric shock and damage.
This guide and procedures described herein are intended for use by skilled workers only.
A skilled worker is defined as a trained and qualified electrician or installer who has all of the following skills and experience:
• Knowledge of the functional principles and operation of on-grid systems.
• Knowledge of the dangers and risks associated with installing and using electrical devices and acceptable mitigation methods.
• Knowledge of the installation of electrical devices.
• Knowledge of and adherence to this guide, the complete installation manual and all safety precautions and best practices.
In order to ensure the normal operation of the BYD Battery System, please download the app Be Connect 2.0 and then finish the
configuration in accordance with this document.
If there are errors generated during the commissioning or operation, please read the Service Guideline and Checklist alongside this
document, or digital version on the website.
If the battery system doesn't start at all, please contact BYD's local after-sales service team within 48 hours. Otherwise, the battery
could be permanently damaged.
Please do not stack up batteries without protective packages when storing or handling batteries, except for installation.
QR code for app.
Be Connect 2.0
Be Connect 2.0
Google Play
APP Store

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BATTERY-BOX PREMIUM HVM US 8.3 and is the answer not in the manual?

Questions and answers

Summary of Contents for BYD BATTERY-BOX PREMIUM HVM US 8.3

  • Page 1 Valid for HVM-US HVM US 8.3, 11.0, 13.8, 16.6, 19.3, 22.1 Please note that this is a Quick Start Guide only, which is a shortened assistance for the installation of the BYD Battery-Box Premium HVM-US. It does not replace the Operating Manual, which must be read and understood completely before installation. Please download and view it on this website: www.bydbatterybox.com.
  • Page 3: Scope Of Delivery

    1. Scope of Delivery Base M4 Screw HVM-US module Hanger (BCU Part Right) Documents Hanger (Wall Part) M5 Screw M6 Bolt and Nut M4 Screw Hanger (BCU Part Left) 2. Not Included in Scope of Delivery DC Cable ExpansionAnchor Bolt Cat5 Shield PE withTerminal Rigid Conduit...
  • Page 4: Installation Location

    3. Tools Network Wire Clamp Phillips Screwdriver Bit Torque Wrench Flat-Head Screwdriver Wire Stripper Cylinder Screwdriver Wrench Tape Measure Drill 4. Installation Location RH. +5 %~ +95 % Max +50 °C (122 °F) Min -10 °C (14 °F)
  • Page 5: Installation

    5. Module Parallel Connection Limitation 3≤N≤8 L=M=N L≠M or L≠N or M ≠ N Max 3 towers in parallel 6. Installation 99.2Ib mm (in)
  • Page 6 Max. continuous current: 50A Max. short circuit current: 2840A,<4ms Operating temperature: 14°F to 122°F IP class: IP55 Protective class: I Manufacturer: Shenzhen BYD Electronics Co., Ltd. Address: No.1, Yan’an Road,Kuichong Street, Dapeng New District, Shenzhen, 518119, P.R. China e.g,HVM-US 8.3 E-Mail: bboxservice@byd.com 10 mm Website: www.bydbatterybox.com...
  • Page 7: Connection Diagram

    7. Connection Diagram Single Tower INVERTER ACT. R 120 DEA. 2 3 4 5 6 7 8 Inver RS485 CAN/RS85 Inver Parallel INVERTER Inverter Comm RS485 COM_Parallel Ethernet ETHERNET PIN8 PIN1 PIN# CAN/RS485 CAN H CAN L EN_GND 12V IN 12V IN_GND RS485B RS485A CAN H...
  • Page 8 Three Towers. Ignore the Slave 1 in the drawing below to get the diagram of two towers. INVERTER C abl e Len g t h ≤ 20 m(65.62 ft) Master Slave 1 Slave 2...
  • Page 9 8. PE and DC Cables Connection 8 mm 5.5 Nm 5/16 in 48.68 Ibf·in Double Insulated External Diameter:4-9 mm (5/32-23/64 in) Cross SectionArea:6-16 mm (9-5 AWG) For the right cable cross section, please check the inverter manual as well.
  • Page 10: Connecting The Network

    9. Connecting the Data Cable to other Battery System(s) Cat5 or higher Cat5 or higher Cat5 or higher Master Slave1 Master Slave1 Slave2 10. Data Cable Connection to Inverter 11. Connecting the Network...
  • Page 11 2 Nm (17.7 Ibf·in) 13. Commissioning Cellular Data Cellular Data Battery-Box Battery-Box DOWNLOAD FIRMWARE WLAN SN:P036T020ZXXXXXXXXXX WLAN WLAN:BYD-XXXX INVERTER AVAILABLE NETWORKS BYD-XXXX Connect to the Battery WiFi to Continue (Password:BYDB-Box) Connected (no lnternet access) 4G-CPE-299430 TO WIFI Settings Saved,encrypted WLAN:BYD-XXXX...
  • Page 12 Note: Skip When adding modules,make sure the SOC of the existing tower is similar to the SOC of the extension module(normally about 30%) Configuration was done according to BYD Battery-Box Configuration/ Compatible Inverter List and Operating Manual. Next Next Next...
  • Page 13: Led Status

    15. Extension Note: Within 5 days before extension, it is recommended to fully charge the original system to SOC 100% at least once. Voltage = X New Batter y Original Batter y Voltage (X)/ V SOC (Y) ≈ SOC Y ≈...
  • Page 14 Communication Options with Inverters CAN Port 8-pin Connector CAN/ 8-Pin CAN H CAN L EN_GND Fronius Primo Gen24 Plus/ Symo Gen24 Plus option a Fronius Primo Gen24 Plus/ Symo Gen24 Plus option b Battery-Box Fronius Battery-Box Fronius Battery-Box 1 2 3 4 5 6 7 8 Battery-Box Cable Length ≤20 m Cable Length ≤20 m...
  • Page 15 WLAN name, password and serial number.
  • Page 16 BYD Global Service US Service BYD AMERICA LLC bboxservice@byd.com us.homeenergy@byd.com + 86 755 89888888-47175 626-491-2333 No. 3009, BYD Road,Pingshan, Shenzhen, 5118118,P.R .China 888 E Walnut, St. Suite 200A, Pasadena, CA 91101, USA www.bydbatterybox.com www.bydbatterybox.com 17359105-00...

Table of Contents