Summary of Contents for Kampmann Katherm NK Series
Page 1
Katherm NK ► Assembly, installation and operating instructions Keep these instructions in a safe place for future use! Issue10/24EN SAP No.1666192...
Table of contents 1 General ..........................5 1.1 About these instructions ........................1.2 Explanation of Symbols.......................... 2 Safety............................ 6 2.1 Correct use............................. 2.2 Limits of operation and use........................2.3 Risk from electrocution!......................... 2.4 Personnel requirements - Qualifications ....................2.5 Personal Protective Equipment ......................3 Transport, storage and packaging..................
Page 4
10.1 Securing against reconnection ....................... 39 10.2 Maintenance Schedule:.......................... 39 10.3 Maintenance work ..........................39 10.3.1 Clean the inside of the unit ........................39 11 Faults ............................ 40 11.1 Fault table.............................. 40 11.2 Start-up after rectification of fault ......................40 12 Disposal ..........................
Katherm NK Assembly, installation and operating instructions General About these instructions These instructions ensure the safe and efficient handling of this equipment. These instructions form an integral part of the equipment and have to be kept in the direct vicinity of the equipment and available to personnel at all times. All personnel must have carefully read through these instructions prior to commencing all work on the equipment.
Katherm NK Assembly, installation and operating instructions Safety This section provides an overview of all important safety aspects to ensure optimum protection of personnel as well as safe and trouble-free operation. In addition to the safety instructions in these operating instructions, the valid safety, accident pre- vention and environmental protection regulations must be observed for the area of use of the unit.
Page 7
Katherm NK Assembly, installation and operating instructions Limits of operation and use Limits of operation Min./max. water temperature °C 15-90 Min./max. air intake temperature °C 15-40 Min./max. air humidity 15-75 Min. operating pressure bar/kPa Max. operating pressure bar/kPa 10/1000 Min./max. glycol percentage 25-50 Tab. 1: Limits of operation We would refer to VDI-2035 Sheets 1 &...
Katherm NK Assembly, installation and operating instructions IMPORTANT NOTE! Danger of frost in cooling mode! There is a risk of the heat exchanger freezing when used in unheated rooms. Make sure that the unit is equipped with a frost protection sensor and/or thermostat in this case. IMPORTANT NOTE! Warning of misuse! In the event of misuse, as itemised below, there is a danger of limited or failing operation of the unit.
Katherm NK Assembly, installation and operating instructions Personnel requirements - Qualifications Expertise The installation of this product requires specialist expertise in heating, cooling, ventilation, installation and electrical engin- eering. As this knowledge is normally acquired through professional training in one of the above fields, it is not dealt with further here.
IMPORTANT NOTE! Warranty claims can only be made within the applicable period for complaints. (More information is avail- able in the T&Cs on the Kampmann website) IMPORTANT NOTE! 2 people are needed to transport the unit. Wear personal protective clothing when transporting the unit.
Katherm NK Assembly, installation and operating instructions Storage Store packaging under the following conditions: Do not store outdoors. Store in a dry and dust-free place. Store in a frost-free place. Do not expose to aggressive media. Protect from direct sunlight. Avoid mechanical vibrations and shocks.
Katherm NK Assembly, installation and operating instructions Construction and function Overview Easy to connect Frame edge (matches grille colour) Load-bearing height adjustment feet Eurokonus valve connection Height adjustment feet with sound insulation Coil Floor trench Roll-up grille Brief description Katherm NK are decentralised units for the heating of room air, for use in hotels, offices and business premises, among oth- ers.
Katherm NK Assembly, installation and operating instructions Installation and wiring Requirements governing the installation site Only install and assemble the unit if the following conditions are met: Make sure that the unit is securely suspended/standing. Ensure that the airflow can circulate freely. Provide adequate space for appropriately sized flow and return water connections on site (Connection to the pipe network [} 19]).
Katherm NK Assembly, installation and operating instructions 6.2.1 Installation steps...
Page 16
Katherm NK Assembly, installation and operating instructions Overall length...
Page 17
Katherm NK Assembly, installation and operating instructions Expansion joint on site on site...
Page 18
Katherm NK Assembly, installation and operating instructions Separately packed roll-up grilles, for instance when using installation covers to protect the trenches from dirt, are rolled up in the factory. The grille can become slightly over-long due to the steel springs extending. Unrolling the grille and laying it flat for a few hours can return the grille to its original length.
Katherm NK Assembly, installation and operating instructions 6.2.2 Screed work The following work steps must be completed before screed work: Water has been correctly connected. The electrical connection has been made correctly. The appliance is correctly positioned and aligned. There are no sound bridges to the bare concrete, especially in the area of the mounting aids. Expansion joints have been provided on site to prevent the appliance from being compressed by the screed or floor.
Katherm NK Assembly, installation and operating instructions 6.3.1 Connection to the pipe network Katherm 137 (only reciprocal connection) Connection side left Window side Connection alternating, connection side left Katherm NK 137 Trench height 92 mm Trench height 120 mm Room side All dimensions in mm Connection side right Window side...
Page 21
Katherm NK Assembly, installation and operating instructions Katherm NK 182, one-sided connection Window side Connection on one side, connection side left Katherm NK 182 Trench height 92 mm Room side Trench height 120 mm All dimensions in mm Window side Connection on one side, connection side left Katherm NK 182 Trench height 150 mm...
Page 22
Katherm NK Assembly, installation and operating instructions Katherm NK 232, one-sided connection Window side Connection on one side, connection side left Katherm NK 232 Trench height 92 mm Trench height 120 mm Room side All dimensions in mm Window side Connection on one side, connection side left Katherm NK 232 Trench height 150 mm...
Page 23
Katherm NK Assembly, installation and operating instructions Katherm NK 300, one-sided connection Window side Connection on one side, connection side left Katherm NK 300 Trench height 92 mm Trench height 120 mm Room side All dimensions in mm Window side Connection on one side, connection side left Katherm NK 300 Trench height 150 mm...
Page 24
Katherm NK Assembly, installation and operating instructions Katherm NK 380, one-sided connection Window side Connection on one side, connection side left Katherm NK 380 Trench height 92 mm Trench height 120 mm Room side All dimensions in mm Window side Connection on one side, connection side left Katherm NK 380 Trench height 150 mm...
Katherm NK Assembly, installation and operating instructions Type overview of valve bodies, presettable / lockable return fittings Trench height [mm] Supply connection Eurocone Return connection Eurocone NK 137 Shut-off return fitting, straight type Valve, axial type Type 194000346911 194000145952 NK 182 Valve axial form type 194000346911 Shut-off return fitting, straight type Type 194000145952...
Page 26
Katherm NK Assembly, installation and operating instructions Front view Height adjustment feet Stable height adjustment Mounting foot Adjusting screw, L= 60 mm, ø 8 mm Rubber carpet pad for sound decoupling Sound decoupling Section Trench width Window side Room side Fig. 3: Height adjustment Dimensions Trench width/ A [mm]...
Katherm NK Assembly, installation and operating instructions 6.3.2 Supply air modules slider Example 232/120 slider Example 300/150 slider Example 182/200 Setting the slider positions Fig. 4: Slider adjustment The supply air module is height-adjusted using threaded rods and connected to the substrate using the mounting bracket. To set the desired volumetric flow on the supply air module, the slider can be moved to different positions.
Page 28
Katherm NK Assembly, installation and operating instructions Design diagrams DN 80 Primary air flow rate Slider position 30% open Slider position 50% open Slider position 75% open Slider position 100% open Sound power level 30 dB(A) DN 100 Primary air flow rate Sash position 30% open Sash position 50% open Slider position 75% open...
Katherm NK Assembly, installation and operating instructions Electrical connection Maximum electrical rating values Mains voltage [VAC] Mains frequency [Hz] Rated power [W] Inrush current [mA] IP class 50/60 IP54 Tab. 4: Technical data actuator, type 146905...
Katherm NK Assembly, installation and operating instructions Pre-commissioning checks During initial commissioning, it must be ensured that all necessary requirements are met so that the appliance can function safely and as intended. Structural tests Check that the unit is securely standing and fixed. Check the horizontal installation/suspension of the unit.
Katherm NK Assembly, installation and operating instructions Operation Operation of electromechanical control Room thermostat, type 194000146904 Room thermostat in a flat surface-mounted housing, with thermal feedback 230 V, white, temperature setting range 5 - 30 °C, temperature range limit- ation is possible Protection class IP 30.
Page 38
Katherm NK Assembly, installation and operating instructions Electronic clock thermostat, type 194000146910 Clock thermostat 230 V / 50 Hz in an attractive white surface-mounted housing with electronic 2-point room temperature control and digital weekly timer Power reserve approx. 4 hours, party switch, switching status display with mode switch, Automatic/Day/Night/Off, adjustable switching difference Temperature adjustment range 10-30 °C Night setback 2-10 K...
Katherm NK Assembly, installation and operating instructions Maintenance 10.1 Securing against reconnection DANGER! Risk of death by unauthorised or uncontrolled restart! Unauthorised or uncontrolled restarting of the equipment can result in serious injury or death. Before restarting, ensure that all safety devices are fitted and working properly and that there is no haz- ard to humans.
Katherm NK Assembly, installation and operating instructions Faults The following chapter describes possible causes of faults and the work needed to rectify them. Should faults occur frequently, shorten the maintenance intervals in line with the actual loading on the unit. Contact the manufacturer with any faults that cannot be rectified using the following information.
Katherm NK Assembly, installation and operating instructions Disposal Electrical and electronic appliances Waste electrical and electronic equipment must be disposed of separately from unsorted municipal waste. This is indicated by the crossed-out wheeled garbage can symbol. If the old appliance contains batteries or accumulators, these must generally be removed from the old appliance before it is handed in at a collection point.
EU-Konformitätserklärung EU Declaration of Conformity Déclaration de Conformité CE Deklaracja zgodności CE EU prohlášení o konformite KAMPMANN Wir (Name des Anbieters, Anschrift): GMBH & Co. KG Friedrich-Ebert-Str. 128-130 We (Supplier’s Name, Address): 49811 Lingen (Ems) Nous (Nom du Fournisseur, Adresse): My (Nazwa Dostawcy, adres): My (Jméno dodavatele, adresa):...
Page 44
Following the provisions of Directive: Conformément aux dispositions de Directive: Zgodnie z postanowieniami Dyrektywy: Odpovídající ustanovení směrnic: 305/2011/EU Bauproduktenverordnung Hendrik Kampmann Lingen (Ems), den 01.09.2020 ___________________________________ Ort und Datum der Ausstellung Name und Unterschrift des Befugten Place and Date of Issue Name and Signature of authorized person Lieu et date d’établissement...
Page 45
Katherm NK Assembly, installation and operating instructions Table Tab. 1 Limits of operation ..............................7 Tab. 2 Water quality................................7 Tab. 3 Technical data ............................... 12 Tab. 4 Technical data actuator, type 146905 ........................29...
Page 48
Country Contact Kampmann UK Ltd. Dial House, Govett Avenue Shepperton, Middlesex, TW17 8AG T +44 1932/ 228592 Great Britain F +44 1932/ 228949 E info@kampmann.co.uk W Kampmann.co.uk...
Need help?
Do you have a question about the Katherm NK Series and is the answer not in the manual?
Questions and answers