  • Page 1 Katherm QK ► Assembly, installation and operating instructions Keep these instructions in a safe place for future use! Issue10/23 CA SAP No.1867735...
  • Page 3: Table Of Contents

    Screed work............................... 19 6.3 Installation............................. 20 6.3.1 Connection to the pipe network ........................ 20 6.4 Katherm QK supply air modules (optional) .................... 22 7 Electrical connection......................24 7.1 Maximum electrical rating values ......................24 7.2 Electromechanical connection, 24 V (*24) ..................... 24 8 Pre-commissioning checks....................
  • Page 4 9.3 Maintenance work ..........................27 9.3.1 Clean the inside of the unit ........................27 10 Faults ............................ 28 10.1 Fault table.............................. 28 11 Certificates..........................29...
  • Page 5: General

    Katherm QK Assembly, installation and operating instructions General About these instructions These instructions ensure the safe and efficient handling of this equipment. These instructions form an integral part of the equipment and have to be kept in the direct vicinity of the equipment and available to personnel at all times.
  • Page 6: Safety

    Katherm QK Assembly, installation and operating instructions Safety This section provides an overview of all important safety aspects to ensure optimum protection of personnel as well as safe and trouble-free operation. In addition to the safety instructions in these operating instructions, the valid safety, accident pre- vention and environmental protection regulations must be observed for the area of use of the unit.
  • Page 7: Limits Of Operation And Use

    Katherm QK Assembly, installation and operating instructions Limits of operation and use Operating limits Min./max. water temperature °C/°F 15-90 / 59-194 Min./max. air intake temperature °C/°F 15-40 / 59-104 Min./max. air humidity 15-75 Min. operating pressure bar/kPa Max. operating pressure...
  • Page 8: Risk From Electrocution

    Katherm QK Assembly, installation and operating instructions IMPORTANT NOTE! Danger of frost in cooling mode! There is a risk of the heat exchanger freezing when used in unheated rooms. Make sure that the unit is equipped with a frost protection sensor and/or thermostat in this case.
  • Page 9: Personnel Requirements - Qualifications

    Katherm QK Assembly, installation and operating instructions Personnel requirements - Qualifications Specialist knowledge The installation of this product requires specialist knowledge of heating, cooling, ventilation, installation and electrical engin- eering. This knowledge, generally learned in vocational training in one of the fields mentioned above, is not described separ- ately.
  • Page 10: Transport, Storage And Packaging

    IMPORTANT NOTE! Warranty claims can only be made within the applicable period for complaints. (More information is avail- able in the T&Cs on the Kampmann website) IMPORTANT NOTE! 2 people are needed to transport the unit. Wear personal protective clothing when transporting the unit.
  • Page 11: Storage

    Katherm QK Assembly, installation and operating instructions Storage Store packaging under the following conditions: Do not store outdoors. Store in a dry and dust-free place. Store in a frost-free place. Do not expose to aggressive media. Protect from direct sunlight.
  • Page 12: Technical Data

    Katherm QK Assembly, installation and operating instructions Technical data Unit Katherm QK (performance values for roll-up grille) Size QK 190 QK 215 Trench width [mm] Trench roll-up grille [mm] Trench linear grille [mm] Trench length [mm] 780 - 3140 780 - 3140 Air volume flow [m³/h]...
  • Page 13: Construction And Function

    Brief description Katherm QK are decentralised units for the heating of room air, for use in hotels, offices and business premises, among oth- ers. Secondary air is drawn in by the fan and passed through the copper/aluminium heat exchanger. The temperature-con-...
  • Page 14: Installation And Wiring

    Katherm QK Assembly, installation and operating instructions Installation and wiring Requirements governing the installation site Only install and assemble the unit if the following conditions are met: Make sure that the unit is securely suspended/standing. Ensure that the airflow can circulate freely.
  • Page 15: Installation Steps

    Katherm QK Assembly, installation and operating instructions 6.2.1 Installation steps...
  • Page 16 Katherm QK Assembly, installation and operating instructions...
  • Page 17 Katherm QK Assembly, installation and operating instructions...
  • Page 18 Katherm QK Assembly, installation and operating instructions Separately packed roll-up grilles, for instance when using installation covers to protect the trenches from dirt, are rolled up in the factory. The grille can become slightly over-long due to the steel springs extending. Unrolling the grille and laying it flat for a few hours can return the grille to its original length.
  • Page 19: Screed Work

    Katherm QK Assembly, installation and operating instructions 6.2.2 Screed work The following work needs to have been completed before screeding can begin: Water has been correctly connected. The electrical connections have been correctly wired. The unit is correctly positioned and levelled.
  • Page 20: Installation

    Assembly, installation and operating instructions Installation 6.3.1 Connection to the pipe network Katherm QK 190, trench height 96 mm (roll-up grille) / 112 mm (linear grille), 24 V electromechanical control (24) QK 190, 24 V electromechanical control (dimensions in mm)
  • Page 21 Katherm QK Assembly, installation and operating instructions Katherm QK 215, trench height 96 mm (roll-up grille) / 112 mm (linear grille), 24 V electromechanical control (24) QK 215, 24 V electromechanical control (dimensions in mm) Front view, showing roll-up grille...
  • Page 22: Katherm Qk Supply Air Modules (Optional)

    51 x 128/ 2 x 5 (oval) 70/ 41.2 190/7.5 400/ 15.7 112/ 4.4 51 x 128/ 2 x 5 (oval) 70/ 41.2 215/8.5 400/ 15.7 112/ 4.4 51 x 128/ 2 x 5 (oval) 70/ 41.2 Tab. 4: Technical data – Katherm QK supply air module...
  • Page 23 Katherm QK Assembly, installation and operating instructions Supply air spigot (oval) 51 mm x 128 mm / 2” x 5” 0 cfm 12 cfm 24 cfm 35 cfm 47 cfm 59 cfm 71cfm Primary air volume flow Slider position 30% open...
  • Page 24: Electrical Connection

    Tab. 5: Maximum electrical rating values Katherm QK Electromechanical connection, 24 V (*24) Note these points in the following wiring diagrams for Katherm QK with electromechanical control: Comply with the details on cable types and cabling with due consideration of NEC and CEC.
  • Page 25 Katherm QK Assembly, installation and operating instructions Katherm QK, electromechanical 24V, 2-pipe, valve drive 24V AC/DC open/close, Control via GA...
  • Page 26: Pre-Commissioning Checks

    Katherm QK Assembly, installation and operating instructions Pre-commissioning checks When commissioning the device for the first time, ensure that all the necessary requirements are met so that the device can function safely and in accordance with its intended use. Structural tests Check that the unit is securely standing and fixed.
  • Page 27: Maintenance

    Katherm QK Assembly, installation and operating instructions Maintenance Securing against reconnection DANGER! Risk of death by unauthorised or uncontrolled restart! Unauthorised or uncontrolled restarting of the equipment can result in serious injury or death. Before restarting, ensure that all safety devices are fitted and working properly and that there is no haz- ard to humans.
  • Page 28: Faults

    Katherm QK Assembly, installation and operating instructions Faults The following chapter describes possible causes of faults and the work needed to rectify them. Should faults occur frequently, shorten the maintenance intervals in line with the actual loading on the unit.
  • Page 29: Certificates

    Brand Name: Katherm QK may be followed by nano; followed by one to four numbers; followed by 24; followed by three numbers; followed by /; followed by three numbers; followed by /; followed by two to five numbers;...
  • Page 30 Brand Name: image only Katherm QK may be followed by nano; followed by one to four numbers; followed by 24; followed by three numbers; followed by /; followed by three numbers; followed by /; followed by two to five numbers;...
  • Page 31 Assembly, installation and operating instructions Table Tab. 1 Operating limits ..............................7 Tab. 2 Operating voltage ..............................7 Tab. 3 Water quality................................7 Tab. 4 Technical data – Katherm QK supply air module....................22 Tab. 5 Maximum electrical rating values ......................... 24...
  • Page 32 Country Contact Kampmann Heating, Cooling, Ventilation Ltd. 1625 Dilworth Drive Unit #207 Kelowna, BC Canada V1Y 8M4 Canada T +1 604/ 3621080 F +1 604/ 6871327 E info@kampmann.ca W Kampmann.ca...