Download Print this page

olympia electronics GR-270/3SC Manual

Non maintained spot light emergency luminaires with 1 white power led

Advertisement

Quick Links

A-270/3SC and A-270/4SC replacement.
It can be done only by a competent person and after the mains interruption.
1. Remove the luminaire from the suspended ceiling (figure 3).
2. Follow step 1 of the installation instructions.
3. Disconnect the connector from the main board and remove the old capacitors pack.
4. Connect the new capacitor pack and place it in the position of the old one.
5. Refit the removed parts and power the device on.
65
125
TEST
CHARGE
FAULT
96
Fault
indication LED
Capacitor
pack
charge
indication
LED
TEST
CHARGE
FAULT
Test
button
Figure 4
A-270/3SC & A-270/4SC
190 mm
180 mm
mounting hole spacing
Top view
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the goods. The period of warranty
is specified in the official catalogue of Olympia Electronics and also in the technical leaflet, which
accompanies each product. This warranty ceases to exist if the buyer does not follow the technical
instructions included in official documents given by Olympia Electronics or if the buyer modifies the goods
provided or has any repairs or re-setting done by a third party, unless Olympia Electronics has fully
agreed to them in writing. Products that have been damaged can be returned to the premises of our
company for repair or replacement, as long as the warranty period is valid.
Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the
buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the
buyer the transportation cost.
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
Page 4 from 4
GR-270/3SC & GR-270/4SC
Corridor
lighting
TEST
CHARGE
FAULT
ATTENTION!!!
During installation follow this light direction.
GR-271/3SC & GR-271/4SC
Open
area
TEST
lighting
CHARGE
FAULT
78 mm
44 mm
Side view
923271003_09_002
NON MAINTAINED SPOT LIGHT
EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED
TECHNICAL CHARACTERISTICS
GR-270/3SC
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BACK UP SOURCE
CAPACITOR PROTECTION
INDICATIONS - CONTROLS
CHARGE TIME
MINIMUM DURATION
LIGHT SOURCE
EMERGENCY ILLUMINATION
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
EXTERNAL DIMENSION
WEIGHT
GUARANTEE
Thank you for your trust in our products
Olympia Electronics - European manufacturer
GENERAL
o
These devices are used indoors (ta 50 C) in
places where emergency luminaires are
needed. The luminaire GR-270/SC is suitable
for corridors lighting and the GR-271/SC for
open area lighting. Each device must be
permanently connected to mains power supply.
In normal operation the capacitor is charging. In
case of a mains power supply failure the device
will light the illumination led automatically in
emergency mode. When the mains power
supply is restored the device turns to normal
operation.
INSTALLATION
To install the luminaire follow the installation
instructions οn page 2.
MANUAL TEST
This test is carried out by pushing the test
button. The light source and the emergency
circuit of the device is monitored. The manual
test can be conducted only if the main power
supply and the capacitor pack is connected.
During this test period the fault indication LED is
blinking.
Page 1 from 4
(for LED MODULE specifications see page 2)
GR-271/3SC
GR-270/4SC
GR-271/4SC
220-240V AC / 50-60Hz
2.9W / 3.4 VA
A-270/3SC
A-270/4SC
From overcharge
Charge, Fault, TEST button
8 hours
60 minutes
1 white power LED
70lm
90lm
IP20
o
-30 to 50 C
Up to 95%
ABS/PC
Ø125 x 65 mm
785gr.
873gr.
10 years
ΑΤΤΕΝΤΙΟΝ!!!
1. Operations for installation and maintainance
must be conducted by authorized personnel only.
2. The device must be connected to the mains
power supply through a fuse dependent by the
total amount of the line's power load.
3 . I n c a s e o f c a p a c i t o r s p a c k o r l a m p
replacement, these must be replaced by parts of
the same type, by the manufacturer or by a
competent person.
4. In case of inactive use for a period greater
than 1 month, disconnect the capacitors pack by
pulling out the capacitors pack's connector.
5. If the luminaire no longer meets the rated
duration of operation, after the corresponding
recharge period, the capacitors pack must be
replaced.
6. I s not allowed to discard capacitors into
t i
common trash bins, they must be
discarded only
in special recycling
points. Do not incinerate.
The light source contained in this luminaire
s h a l l o n l y b e r e p l a c e d b y t h e
manufacturer, or his agent, or a similar qualified
person.
NOTE! The light source is non-user replaceable.
923271003_09_002

Advertisement

loading
Need help?

Need help?

Do you have a question about the GR-270/3SC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for olympia electronics GR-270/3SC

  • Page 1 The light source contained in this luminaire Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the During this test period the fault indication LED is s h a l l o n l y b e r e p l a c e d b y t h e buyer depending on the reason of defection.
  • Page 2 Maintained operation: The luminaire lights its illumination source, when it is powered by the mains power supply or not. Step 3 LED MODULE CHARACTERISTICS Continue to push upwards until the lamp locks. GR-270/3SC GR-271/3SC GR-270/4SC GR-271/4SC Manufacturer Olympia Electronics S.A 230V Model Number 0405185 Voltage Range 2.7-2.9VDC Figure 3 Nominal Power 0.45W 0.6W...

This manual is also suitable for:

Gr-271/3scGr-270/4scGr-271/4sc