Demir Dokum DT4-D 50 INT I Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Quick Links

DT4-D 50 INT I
DT4-D 65 INT I
DT4-D 80 INT I
en Installation and maintenance instructions
en Installation and maintenance instructions
en Installation and maintenance instructions
en Installation and maintenance instructions
en Installation and maintenance instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DT4-D 50 INT I and is the answer not in the manual?

Questions and answers

Summary of Contents for Demir Dokum DT4-D 50 INT I

  • Page 1 DT4-D 50 INT I DT4-D 65 INT I DT4-D 80 INT I en Installation and maintenance instructions en Installation and maintenance instructions en Installation and maintenance instructions en Installation and maintenance instructions en Installation and maintenance instructions...
  • Page 2 Installation and maintenance instructions ..3 Installation and maintenance instructions ..14 Installation and maintenance instructions ..25 Installation and maintenance instructions ..36 Installation and maintenance instructions ..47...
  • Page 3: Table Of Contents

    Installation and maintenance instructions Contents Safety ..............4 Action-related warnings ......... 4 Intended use ............4 General safety information ........4 Regulations (directives, laws, standards) ....6 Notes on the documentation ......7 Observing other applicable documents ....7 Storing documents..........7 Validity of the instructions ........
  • Page 4: Safety

    Safety Any other use that is not specified in these instructions, or use beyond that specified in Action-related warnings this document, shall be considered improper use. Any direct commercial or industrial use Classification of action-related warnings is also deemed to be improper. The action-related warnings are classified in accordance with the severity of the possible Caution.
  • Page 5 ▶ Ensure that the installation surface has 1.3.5 Risk of material damage caused by using an unsuitable tool sufficient load-bearing capacity to bear the operating weight of the product. ▶ Use the correct tool. 1.3.10 Excessive water pressure 1.3.6 Risk of material damage caused by frost Excessive water pressure may lead to dam- age to the product and, as a result, cause in-...
  • Page 6: Regulations (Directives, Laws, Standards)

    Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, directives, ordinances and laws. Installation and maintenance instructions 8000031435_01...
  • Page 7: Notes On The Documentation

    Product article number against moving horizontally and vertically. Products that are not installed are stored in the manufac- DT4-D 50 INT I 8000031383 turer's packaging. The products must be stored under stand- DT4-D 65 INT I...
  • Page 8: Requirements For The Installation Site

    Requirements for the installation site Drill the holes. Insert the rawl plugs into the holes and screw in the ▶ Select the installation site so that the cables can be eas- screws. ily routed. – Clearance between the screw and the wall: ≈ ▶...
  • Page 9: Electrical Installation

    – Connection pressure: ≥ 0.7 MPa Start-up – Pressure setting: 0.3 to 0.4 MPa Open the cold-water stopcock. Open the hot water taps. Wait until water flows out of the hot water taps. Electrical installation Close the hot water taps. Check the expansion relief valve by opening the drain Only qualified electricians are allowed to carry out the elec- cock on the expansion relief valve.
  • Page 10: Maintenance

    Maintenance Checking the inner vessel and components for scale deposition Checking the magnesium protection anode Disconnect the product from the power supply. (→ Page 10) Empty the product. (→ Page 11) Remove the flange. (→ Page 10) If necessary, clean the inner vessel with descaling agents or by carefully scraping it with a wooden spat- ula.
  • Page 11: 11 Customer Service

    ▶ Remove the mains connection lines. Emptying the product Close the cold water stop cock. Open a hot water valve connected to the product. Loosen the connection between the cold water pipe and the product. Drain the domestic hot water cylinder via the product's cold water pipe.
  • Page 12: Appendix

    Appendix Dimensions and dimension drawing G ½ G ½ Dimensions DT4-D 50 INT I 555 mm 408 mm DT4-D 65 INT I 680 mm 533 mm DT4-D 80 INT I 805 mm 658 mm Technical data Filling volume Operating weight...
  • Page 13: Technical Data - General

    Technical data – General Heat insulation PU foam, CFC-free Inner vessel Steel, enamelled, with magnesium protection anode Fault display view Display Cause Troubleshooting Domestic hot water overheating (≥85 °C for Make sure that the temperature of the cold water at the cylinder's 2 seconds) cold water connection is <85 °C.
  • Page 14 Installation and maintenance instructions Contents Safety ..............15 Action-related warnings ........15 Intended use ............15 General safety information ........15 Regulations (directives, laws, standards) .... 17 Notes on the documentation ......18 Observing other applicable documents ....18 Storing documents..........18 Validity of the instructions ........
  • Page 15: Safety

    Safety Any other use that is not specified in these instructions, or use beyond that specified in Action-related warnings this document, shall be considered improper use. Any direct commercial or industrial use Classification of action-related warnings is also deemed to be improper. The action-related warnings are classified in accordance with the severity of the possible Caution.
  • Page 16 ▶ Ensure that the installation surface has 1.3.5 Risk of material damage caused by using an unsuitable tool sufficient load-bearing capacity to bear the operating weight of the product. ▶ Use the correct tool. 1.3.10 Excessive water pressure 1.3.6 Risk of material damage caused by frost Excessive water pressure may lead to dam- age to the product and, as a result, cause in-...
  • Page 17: Regulations (Directives, Laws, Standards)

    Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, directives, ordinances and laws. 8000031435_01 Installation and maintenance instructions...
  • Page 18: Notes On The Documentation

    Product article number against moving horizontally and vertically. Products that are not installed are stored in the manufac- DT4-D 50 INT I 8000031383 turer's packaging. The products must be stored under stand- DT4-D 65 INT I...
  • Page 19: Requirements For The Installation Site

    Requirements for the installation site Drill the holes. Insert the rawl plugs into the holes and screw in the ▶ Select the installation site so that the cables can be eas- screws. ily routed. – Clearance between the screw and the wall: ≈ ▶...
  • Page 20: Electrical Installation

    – Connection pressure: ≥ 0.7 MPa Start-up – Pressure setting: 0.3 to 0.4 MPa Open the cold-water stopcock. Open the hot water taps. Wait until water flows out of the hot water taps. Electrical installation Close the hot water taps. Check the expansion relief valve by opening the drain Only qualified electricians are allowed to carry out the elec- cock on the expansion relief valve.
  • Page 21: Maintenance

    Maintenance Checking the inner vessel and components for scale deposition Checking the magnesium protection anode Disconnect the product from the power supply. (→ Page 21) Empty the product. (→ Page 22) Remove the flange. (→ Page 21) If necessary, clean the inner vessel with descaling agents or by carefully scraping it with a wooden spat- ula.
  • Page 22: 11 Customer Service

    ▶ Remove the mains connection lines. Emptying the product Close the cold water stop cock. Open a hot water valve connected to the product. Loosen the connection between the cold water pipe and the product. Drain the domestic hot water cylinder via the product's cold water pipe.
  • Page 23: Appendix

    Appendix Dimensions and dimension drawing G ½ G ½ Dimensions DT4-D 50 INT I 555 mm 408 mm DT4-D 65 INT I 680 mm 533 mm DT4-D 80 INT I 805 mm 658 mm Technical data Filling volume Operating weight...
  • Page 24: Technical Data - General

    Technical data – General Heat insulation PU foam, CFC-free Inner vessel Steel, enamelled, with magnesium protection anode Fault display view Display Cause Troubleshooting Domestic hot water overheating (≥85 °C for Make sure that the temperature of the cold water at the cylinder's 2 seconds) cold water connection is <85 °C.
  • Page 25 Installation and maintenance instructions Contents Safety ..............26 Action-related warnings ........26 Intended use ............26 General safety information ........26 Regulations (directives, laws, standards) .... 28 Notes on the documentation ......29 Observing other applicable documents ....29 Storing documents..........29 Validity of the instructions ........
  • Page 26: Safety

    Safety Any other use that is not specified in these instructions, or use beyond that specified in Action-related warnings this document, shall be considered improper use. Any direct commercial or industrial use Classification of action-related warnings is also deemed to be improper. The action-related warnings are classified in accordance with the severity of the possible Caution.
  • Page 27 ▶ Ensure that the installation surface has 1.3.5 Risk of material damage caused by using an unsuitable tool sufficient load-bearing capacity to bear the operating weight of the product. ▶ Use the correct tool. 1.3.10 Excessive water pressure 1.3.6 Risk of material damage caused by frost Excessive water pressure may lead to dam- age to the product and, as a result, cause in-...
  • Page 28: Regulations (Directives, Laws, Standards)

    Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, directives, ordinances and laws. Installation and maintenance instructions 8000031435_01...
  • Page 29: Notes On The Documentation

    Product article number against moving horizontally and vertically. Products that are not installed are stored in the manufac- DT4-D 50 INT I 8000031383 turer's packaging. The products must be stored under stand- DT4-D 65 INT I...
  • Page 30: Requirements For The Installation Site

    Requirements for the installation site Drill the holes. Insert the rawl plugs into the holes and screw in the ▶ Select the installation site so that the cables can be eas- screws. ily routed. – Clearance between the screw and the wall: ≈ ▶...
  • Page 31: Electrical Installation

    – Connection pressure: ≥ 0.7 MPa Start-up – Pressure setting: 0.3 to 0.4 MPa Open the cold-water stopcock. Open the hot water taps. Wait until water flows out of the hot water taps. Electrical installation Close the hot water taps. Check the expansion relief valve by opening the drain Only qualified electricians are allowed to carry out the elec- cock on the expansion relief valve.
  • Page 32: Maintenance

    Maintenance Checking the inner vessel and components for scale deposition Checking the magnesium protection anode Disconnect the product from the power supply. (→ Page 32) Empty the product. (→ Page 33) Remove the flange. (→ Page 32) If necessary, clean the inner vessel with descaling agents or by carefully scraping it with a wooden spat- ula.
  • Page 33: 11 Customer Service

    ▶ Remove the mains connection lines. Emptying the product Close the cold water stop cock. Open a hot water valve connected to the product. Loosen the connection between the cold water pipe and the product. Drain the domestic hot water cylinder via the product's cold water pipe.
  • Page 34: Appendix

    Appendix Dimensions and dimension drawing G ½ G ½ Dimensions DT4-D 50 INT I 555 mm 408 mm DT4-D 65 INT I 680 mm 533 mm DT4-D 80 INT I 805 mm 658 mm Technical data Filling volume Operating weight...
  • Page 35: Technical Data - General

    Technical data – General Heat insulation PU foam, CFC-free Inner vessel Steel, enamelled, with magnesium protection anode Fault display view Display Cause Troubleshooting Domestic hot water overheating (≥85 °C for Make sure that the temperature of the cold water at the cylinder's 2 seconds) cold water connection is <85 °C.
  • Page 36 Installation and maintenance instructions Contents Safety ..............37 Action-related warnings ........37 Intended use ............37 General safety information ........37 Regulations (directives, laws, standards) .... 39 Notes on the documentation ......40 Observing other applicable documents ....40 Storing documents..........40 Validity of the instructions ........
  • Page 37: Safety

    Safety Any other use that is not specified in these instructions, or use beyond that specified in Action-related warnings this document, shall be considered improper use. Any direct commercial or industrial use Classification of action-related warnings is also deemed to be improper. The action-related warnings are classified in accordance with the severity of the possible Caution.
  • Page 38 ▶ Ensure that the installation surface has 1.3.5 Risk of material damage caused by using an unsuitable tool sufficient load-bearing capacity to bear the operating weight of the product. ▶ Use the correct tool. 1.3.10 Excessive water pressure 1.3.6 Risk of material damage caused by frost Excessive water pressure may lead to dam- age to the product and, as a result, cause in-...
  • Page 39: Regulations (Directives, Laws, Standards)

    Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, directives, ordinances and laws. 8000031435_01 Installation and maintenance instructions...
  • Page 40: Notes On The Documentation

    The cylinder is equipped with external heat insulation. The Product article number cylinder vessel is made of enamelled steel. The heating ele- DT4-D 50 INT I 8000031383 ments that transfer the heat are located inside the vessel. As additional corrosion protection, the vessel has a magnesium...
  • Page 41: Requirements For The Installation Site

    Requirements for the installation site Drill the holes. Insert the rawl plugs into the holes and screw in the ▶ Select the installation site so that the cables can be eas- screws. ily routed. – Clearance between the screw and the wall: ≈ ▶...
  • Page 42: Electrical Installation

    – Connection pressure: ≥ 0.7 MPa Start-up – Pressure setting: 0.3 to 0.4 MPa Open the cold-water stopcock. Open the hot water taps. Wait until water flows out of the hot water taps. Electrical installation Close the hot water taps. Check the expansion relief valve by opening the drain Only qualified electricians are allowed to carry out the elec- cock on the expansion relief valve.
  • Page 43: Maintenance

    Maintenance Checking the inner vessel and components for scale deposition Checking the magnesium protection anode Disconnect the product from the power supply. (→ Page 43) Empty the product. (→ Page 44) Remove the flange. (→ Page 43) If necessary, clean the inner vessel with descaling agents or by carefully scraping it with a wooden spat- ula.
  • Page 44: 11 Customer Service

    ▶ Remove the mains connection lines. Emptying the product Close the cold water stop cock. Open a hot water valve connected to the product. Loosen the connection between the cold water pipe and the product. Drain the domestic hot water cylinder via the product's cold water pipe.
  • Page 45: Appendix

    Appendix Dimensions and dimension drawing G ½ G ½ Dimensions DT4-D 50 INT I 555 mm 408 mm DT4-D 65 INT I 680 mm 533 mm DT4-D 80 INT I 805 mm 658 mm Technical data Filling volume Operating weight...
  • Page 46: Technical Data - General

    Technical data – General Heat insulation PU foam, CFC-free Inner vessel Steel, enamelled, with magnesium protection anode Fault display view Display Cause Troubleshooting Domestic hot water overheating (≥85 °C for Make sure that the temperature of the cold water at the cylinder's 2 seconds) cold water connection is <85 °C.
  • Page 47 Installation and maintenance instructions Contents Safety ..............48 Action-related warnings ........48 Intended use ............48 General safety information ........48 Regulations (directives, laws, standards) .... 50 Notes on the documentation ......51 Observing other applicable documents ....51 Storing documents..........51 Validity of the instructions ........
  • Page 48: Safety

    Safety Any other use that is not specified in these instructions, or use beyond that specified in Action-related warnings this document, shall be considered improper use. Any direct commercial or industrial use Classification of action-related warnings is also deemed to be improper. The action-related warnings are classified in accordance with the severity of the possible Caution.
  • Page 49 ▶ Ensure that the installation surface has 1.3.5 Risk of material damage caused by using an unsuitable tool sufficient load-bearing capacity to bear the operating weight of the product. ▶ Use the correct tool. 1.3.10 Excessive water pressure 1.3.6 Risk of material damage caused by frost Excessive water pressure may lead to dam- age to the product and, as a result, cause in-...
  • Page 50: Regulations (Directives, Laws, Standards)

    Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, directives, ordinances and laws. Installation and maintenance instructions 8000031435_01...
  • Page 51: Notes On The Documentation

    The cylinder is equipped with external heat insulation. The Product article number cylinder vessel is made of enamelled steel. The heating ele- DT4-D 50 INT I 8000031383 ments that transfer the heat are located inside the vessel. As additional corrosion protection, the vessel has a magnesium...
  • Page 52: Requirements For The Installation Site

    Requirements for the installation site Drill the holes. Insert the rawl plugs into the holes and screw in the ▶ Select the installation site so that the cables can be eas- screws. ily routed. – Clearance between the screw and the wall: ≈ ▶...
  • Page 53: Electrical Installation

    – Connection pressure: ≥ 0.7 MPa Start-up – Pressure setting: 0.3 to 0.4 MPa Open the cold-water stopcock. Open the hot water taps. Wait until water flows out of the hot water taps. Electrical installation Close the hot water taps. Check the expansion relief valve by opening the drain Only qualified electricians are allowed to carry out the elec- cock on the expansion relief valve.
  • Page 54: Maintenance

    Maintenance Checking the inner vessel and components for scale deposition Checking the magnesium protection anode Disconnect the product from the power supply. (→ Page 54) Empty the product. (→ Page 55) Remove the flange. (→ Page 54) If necessary, clean the inner vessel with descaling agents or by carefully scraping it with a wooden spat- ula.
  • Page 55: 11 Customer Service

    ▶ Remove the mains connection lines. Emptying the product Close the cold water stop cock. Open a hot water valve connected to the product. Loosen the connection between the cold water pipe and the product. Drain the domestic hot water cylinder via the product's cold water pipe.
  • Page 56: Appendix

    Appendix Dimensions and dimension drawing G ½ G ½ Dimensions DT4-D 50 INT I 555 mm 408 mm DT4-D 65 INT I 680 mm 533 mm DT4-D 80 INT I 805 mm 658 mm Technical data Filling volume Operating weight...
  • Page 57: Technical Data - General

    Technical data – General Heat insulation PU foam, CFC-free Inner vessel Steel, enamelled, with magnesium protection anode Fault display view Display Cause Troubleshooting Domestic hot water overheating (≥85 °C for Make sure that the temperature of the cold water at the cylinder's 2 seconds) cold water connection is <85 °C.
  • Page 60 Supplier Türk DemirDöküm Fabrikaları A.Ş. Atatürk Mahallesi Meriç Caddesi No: 1/4 34758 / Ataşehir ‒ İstanbul Türkiye Tel. 0216 516 2000 Faks 0216 516 2007 Müşteri iletişim merkezi 0850 2221833 8000031435_01 info@demirdokum.com.tr www.demirdokum.com.tr Publisher/manufacturer TÜRK DEMIRDÖKÜM FABRIKALARI A.S. 4 Eylül Mah. Osman Rusçuk Cad. No: 5 11300 / Bozüyük ‒...