Download Print this page
Demir Dokum Atromix P 20-A/2(HUA/MD) Operating Instructions Manual

Demir Dokum Atromix P 20-A/2(HUA/MD) Operating Instructions Manual

Hide thumbs Also See for Atromix P 20-A/2(HUA/MD):

Advertisement

Quick Links

Operating instruc-
tions
Atromix
Atromix P 20 ... 28 – A/2 (H-
UA/MD)
UA

Advertisement

loading
Need help?

Need help?

Do you have a question about the Atromix P 20-A/2(HUA/MD) and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Demir Dokum Atromix P 20-A/2(HUA/MD)

  • Page 1 Operating instruc- tions Atromix Atromix P 20 … 28 – A/2 (H- UA/MD)
  • Page 2 Contents Contents Decommissioning...... 12 Temporarily decommissioning Safety ..........3 the product........12 Action-related warnings ....3 Permanently decommissioning the product........12 Intended use ........3 Recycling and disposal..... 12 General safety information..... 4 Guarantee and customer Notes on the documentation ..7 service ........
  • Page 3 Safety 1 1 Safety ing installations and for do- mestic hot water generation. 1.1 Action-related warnings Intended use includes the fol- Classification of action-re- lowing: lated warnings – observance of the operating The action-related warnings instructions included for the are classified in accordance product and any other install- with the severity of the pos- ation components...
  • Page 4 1 Safety ▶ Do not use any electrical 1.3 General safety information switches, mains plugs, door- bells, telephones or other 1.3.1 Danger caused by communication systems in improper operation the building. Improper operation may present ▶ Close the emergency control a danger to you and others, and valve or the main isolator.
  • Page 5 Safety 1 – to the entire condensate 1.3.5 Risk of death due to explosive and flammable discharge system – to the expansion relief valve materials – to the drain pipework ▶ Do not use the product in – to constructional condi- storage rooms that contain tions that may affect the explosive or flammable sub-...
  • Page 6 1 Safety 1.3.13 Небезпека! ives, ammonia compounds, dust or similar substances may ▶ Перед монтажем прочитати lead to corrosion on the product інструкцію з установки! and in the air/flue pipe. ▶ Перед введенням в експлу- ▶ Ensure that the combustion атацію...
  • Page 7 Notes on the documentation 2 2 Notes on the 3.2 Control elements documentation 2.1 Observing other applicable documents ▶ You must observe all operating instruc- reset tions enclosed with the system compon- ents. 2.2 Storing documents Display Reset button rotary knob button ▶...
  • Page 8 3 Product description 3.3 Data plate Symbol Meaning Domestic hot water genera- The data plate is mounted on the side of tion the product at the factory. – Permanently on: Do- The data plate keeps record of the country mestic hot water activated in which the product is to be installed.
  • Page 9 Operation 4 4 Operation 3.4 CE marking 4.1 Operating levels The product has two operating levels.   – The end user level contains information The CE marking shows that the products and setting options that you require as comply with the basic requirements of the the end user.
  • Page 10 4 Operation 4.4 Checking the heating system Note pressure The competent person is respons- ible for filling the heating installa- 1. Once a month, check that the pressure tion the first time, any subsequent in the central heating system, which top-ups and the water quality.
  • Page 11 Troubleshooting 5 ▶ 5.2 Fault codes in the display Set the required heating flow temperat- ure on the control (→ Control operating Fault codes have priority over all other dis- instructions). plays. If several faults occur at the same time, the corresponding codes are dis- 4.8 Setting the domestic hot water played alternately for two seconds each.
  • Page 12 7 Decommissioning 7 Decommissioning 9 Guarantee and customer service 7.1 Temporarily decommissioning the product 9.1 Guarantee ▶ Temporarily decommission the product Інформацію щодо гарантії виробника ви only if there is no risk of frost. можете отримати, звернувшись за кон- ▶ Switch off the product via the main тактною...
  • Page 13 Appendix Appendix A Adjustable values – overview Adjustable values Values Unit Increment, select Default set- ting Min. Max. Heating mode ℃ Heating flow temperature Current value Preset in the in- stallation DHW mode ℃ Domestic hot water temper- Current value ature ℃...
  • Page 14 Appendix Fault Cause Measure Product does not After five unsuccessful ignition attempts, Press the button. The product start up: the product switches to fault mode (fault carries out a new ignition attempt. message: F.28). If you have been unable to elimin- –...
  • Page 16 Manufacturer/Supplier TÜRK DEMIRDÖKÜM FABRIKALARI A.S. 4 Eylül Mah. Osman Rusçuk Cad. No: 5 ‒ 11300 / Bozüyük ‒ Bilecik www.demirdokum.com.tr 0020301215_00 0020301215_00 ‒ 27.03.2020 © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent. Subject to technical modifications.