Download Print this page

Advertisement

Quick Links

Important!
This user's manual is a main operating document intended
for technical, maintenance, and operating staff.
The manual contains information about purpose, technical
details, operating principle, design, and installation of the
Bodo unit and all its modifications.
Read the user's manual carefully
before proceeding with installation
works. Compliance with the manual
requirements ensures reliable
operation and long service life of the
unit. Keep the user's manual available
as long as you use the unit. You may
need to reread the information on
the product servicing.
This unit is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the unit by a person
responsible for their safety.
Children should be supervised to ensure that they
do not play with the unit.
This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision
or instruction concerning use of the appliance in a
61
Technical and maintenance staff must have theoretical
and practical training in the field of ventilation systems
and should be able to work in accordance with workplace
safety rules as well as construction norms and standards
applicable in the territory of the country.
safe way and understand the hazards involved.
Cleaning and user maintenance shall not be made
by children without supervision.
Children shall not play with the appliance.
Precautions must be taken to avoid the back-flow
of gases into the room from the open flue of gas or
other fuel-burning appliances.
The appliance may adversely affect the safe
operation of appliances burning gas or other fuels
(including those in other rooms) due to back flow
of combustion gases. These gases can potentially
result in carbon monoxide poisoning. After
installation of the unit the operation of flued gas
appliances should be tested by a competent person
to ensure that back flow of combustion gases does
not occur.
Connection to the mains must be made through a
disconnecting device, which is integrated into the
fixed wiring system in accordance with the wiring
rules for design of electrical units, and has a contact
separation in all poles that allows for full discon-
nection under overvoltage category III conditions.
Ensure that the unit is switched off from the supply

Advertisement

loading
Need help?

Need help?

Do you have a question about the Bodo Prime and is the answer not in the manual?

Questions and answers

Summary of Contents for Flexit Bodo Prime

  • Page 1 Important! This user’s manual is a main operating document intended Technical and maintenance staff must have theoretical for technical, maintenance, and operating staff. and practical training in the field of ventilation systems The manual contains information about purpose, technical and should be able to work in accordance with workplace details, operating principle, design, and installation of the safety rules as well as construction norms and standards Bodo unit and all its modifications.
  • Page 2 mains before removing the guard. insecticides, etc. Do not close or block the intake or extract vents All operations described in this manual must be in order to ensure the efficient air flow. performed by qualified personnel only, properly Do not sit on the unit and do not put objects on it. trained and qualified to install, make electrical The information in this user’s manual was correct connections and maintain ventilation units.
  • Page 3: Delivery Set

    Delivery set Fan ................1 pc. Screws with dowels ..........3 pcs. Plastic screwdriver (for Arc models only) ..1 pc. User’s manual ............1 pc. Packing box ............1 pc. Mounting template ..........1 pc. Template for cut-out ..........1 pc. Ø 100 mm spigot ..........1 pc. Ø...
  • Page 4: Overall Dimensions

    Overall dimensions Dimensions [mm] Ø d Ø D Bodo Fan modifications Functions Model Humidity Air quality Temperature Motion sensor Light sensor Wi-Fi sensor sensor sensor Bodo Prime Bodo Supreme...
  • Page 5: Fan Control

    Fan control Bodo Prime is controlled using a multi-position switch. Main operating modes Preset sensor triggering parameters • By default, the fan either runs continuously at • The humidity sensor works in automatic mode. It accumulates statistical information on the natural...
  • Page 6 The fan has 8 preset operation modes, which are regulated by a multi-position switch. Mode 1: the fan operates in constant ventilation mode at a speed of 20 m /h; the motion sensor, light sensor at 60 m /h and humidity sensor at 90 m are active.
  • Page 7 Bodo Supreme is controlled via an app on a mobile device. Flexit Fans– App Store Flexit Fans – Google Play To start using the fan, connect to it as a Wi-Fi access point with the name (FAN: + 16 character ID number) indicated on the control board and on the fan casing.
  • Page 8 To recover the Wi-Fi password or connect to a fan after changes in the Wi-FI network, the Setup Mode is provided. To activate the mode, it is necessary to power off the device for not less than 3 seconds and to power on the device for not more than 2 seconds.
  • Page 9 Air quality sensor: • Manual mode allows you to set the air quality sensor threshold based on the air quality index in the range from 50 to 250 units. For an explanation of the air quality index values, see next page. If the level of air pollution exceeds the set level, the fan switches to the speed selected in the application 60, 90 m³/h or maximum.
  • Page 10 Index for air quality classification (IAQ) on levels of volatile organic compounds in air IAQ Index Air quality Influence (long term) Recommended action 0—50 Excellent Fresh air; best for well-being No action required 51—100 Good Does not irritate mucous or No action required respiratory passages and does not affect well-being...
  • Page 11: Installation

    Installation The fan can be installed on the ceiling or on the wall, with air discharge into a round air duct of suitable diameter. A fan with direct air discharge upwards must not be installed. The unit can be installed in bathroom zone 1 (except in case of external electrical connection with power cable from above, see next page), provided that the installation and wiring are in accordance with IEC...
  • Page 12 Fan installation sequence: Cut off power supply to the unit and make sure that the electricity is switched off. For 12 V power supply, install an external DC power switch (not included in the delivery set). Run the power cable to the vent hole. The cable can be entered through the back at the top or bottom of the fan (1, 2), or through the top of the fan (3) if the cable is routed outside the wall/...
  • Page 13 Remove the front panel from the fan and the cover. To route the cable from above, a hole must be cut in the top of the fan’s front panel according to the recess markings. Use the template for cut-out to mark the cutting location. The front panel has less thickness where the template is to be attached.
  • Page 14 Use the mounting template to mark the screw holes and power supply. Drill the holes and install the fan. Note: Install the fan according to the direction indicated on the fan (”UP”) using the integrated level. Run the power supply cable through the cable gland in the selected way and connect the fan to the power mains as shown in the wiring diagram.
  • Page 15 12 V DC Remove the block plugs before connecting to the XP2 connector. WARNING! Connect power supply to the XP1 or XP2 connector. Do not connect two power supplies at the same time. Install the cover and the front panel back on the fan casing.
  • Page 16: Technical Maintenance

    Technical maintenance The fan maintenance periodicity is at least once per 6 months. Maintenance steps: • Disconnect the fan from power supply and make sure electricity has been turned off. • Remove the front panel, wipe the fan with a dry cloth or a brush.
  • Page 17: Troubleshooting

    Troubleshooting Problem Possible reasons Troubleshooting Make sure the power supply line When the unit is connected to power No power supply. is connected correctly, otherwise mains, the fan does not rotate and troubleshoot the connection error. does not respond to any controls. Internal connection fault.
  • Page 18: Warranty Claims

    Warranty claims Disposal WARNING! Warranty claims will only be valid The symbol on the product shows that this if the instructions in the manuals have been product must not be treated as household followed. waste. It must be taken to a collection point Warranty claims for this product are subject to the for recycling electrical and electronic existing terms of sale, and the product must have...
  • Page 19 WEEE and the RoHS Directive. EE-products (Electrical and Electronic products) Flexit meets its obligations under the waste regulations/EE regulations. EE waste must not be disposed of with other waste. When no longer needed it should be handed into a dealer or appropriate location at a local disposal/ collection centre.