IT2700 用户手册 Quality Certification and Assurance We certify that IT2700 series power supply meets all the published specifications at time of shipment from the factory. Warranty ITECH warrants that the product will be free from defects in material and workmanship under normal use for a period of one ( 1) year from the date of delivery ( except those described in the Limitation of Warranty below).
Failure to comply with these precautions or specific warnings elsewhere in this manual will constitute a default under safety standards of design, manufacture and intended use of the instrument. ITECH assumes no liability for the customer’s failure to comply with these precautions.
PC computer control, there are two ways of computer control, the PV2700 software or use a browser to log on to the Web server control. The IT2700 series instruments come with a built-in web server that you can control directly from your computer's Internet browser. A maximum of two simultaneous connections are allowed.
Page 11
Web Control: Enables the Web control to begin controlling the instrument. This page allows you to monitor and control the instrument; ⚫ LAN Configuration: Reconfigure the LAN parameters; Manual: Go to the ITECH official website and view or download the relevant ⚫ documents. ⚫...
2.2.5 Setting Display Layout The IT2700 series instruments support up to 8 channels of simultaneous output, each output has its own measurement capability. When the Meter view is displayed, the measurement system continuously measures the output voltage and current.
Digital IO function introduction for details. 3.5 Select Voltage or Current Operation Mode The IT2700 series power system can realize different functions by installing different modules. The module can be a power supply module or a load module, and when used as a power supply, the operation mode can be selected as CV...
Operation and Application 3.6 Select Constant-status Operation Mode The IT2700 series power system can realize different functions by installing different modules. The module can be a power module or a load module, and when used as a load, the operation modes include the following: Basic Operation Mode ⚫...
Page 32
The CR mode ensures that the UUT voltage outputs remain stable when the load varies. Complex Operation Mode IT2700 series complex operating modes include CC+CV, CC+CR, CR+CV, CP+CV and CC+CP+CR+CV modes, which can satisfy a wide range of test requirements.
3.7 Config Menu Function IT2700 series power system install different modules can realize different functions, different modules, config menu setup items are different, please refer to the Config menu introduction content for specific parameter introduction.
V/ms or A/ms depending on the mode. 3.7.2 Remote Measurement Function The IT2700 series instruments support both local and remote measurements, of which remote measurements are suitable for scenarios that require high measurement accuracy (see the IT2700 user user manual for more information).
110% of the current range. Under CV mode, short-circuit current equals to current when constant voltage is 0 V. 3.8 Protection Function The IT2700 series power system has different protection menus when using different modules. Press [Protect] button or click Protect function in Menu to enter Protect Configuration interface, the menu list and introduction of Protect function are shown below.
When you return power to the instrument, verify that the cooling fan is running. If not, please contact ITECH Technical Support. Leaving the instrument powered on with an inoperative cooling fan may result in damage to the instrument.
Operation and Application 3.9 Timing Output Function Up to 8 modules can be installed in the IT2700 series power system. On delay or Off delay can be set for different channels, through which timing outputs between multiple channels can be realized.
CH1. 3.12 Remote Measurement Function The IT2700 series power system supports two connection methods: Local measurement and Remote sensing. The remote sensing is used for maximizing measurement accuracy. (The connection refer to the IT2700 user manual).
IT2700 series instruments. 4.1 LIST The IT2700 series instrument supports the function of editing LIST sequences with multiple output points. You can set up to 2000 steps per file. You can edit the voltage/current value, slope and duration of each step.
4.1.3 Import/Export List File Import List file IT2700 series support import list file function, The user can finish the editing of List file in Excel and import it into the software. This function simplifies the List file edit and facilitates user operation.
6.3 Setting Communication This menu item is used to set the communication method between the instrument and the PC. IT2700 series instruments are equipped with USB and LAN interfaces as standard. The user selects the used communication interface in the menu, and the user only needs to set the communication parameters and keep them consistent with the PC settings.
When recalling is completed, the interface will display the saved detailed parameters. 6.7 Screen Capture Function IT2700 series power supply has the screen capture function. Insert the USB equipment into the USB interface of the front panel, and press [Print] to capture and save the screen into the USB disk.
Host. 6.8 Query the System Log The IT2700 series power system provides the system operation Log query function. Click shift+5[Log] to enter the Log query interface. You can view historical system operation records on this screen.