ООО "Техэнком"
Контрольно-измерительные приборы и оборудование
www.tehencom.com
Remote Control
strings must start and end with paired quotation marks; and single quotation
marks or double quotation marks are both allowed. Quotation mark separators
may also act as one part of a string, they can be typed twice without any
character added between them. String parameter is used in the following
command:
DISPlay:TEXT <quoted string>
For example, the following commands display message of "WAITING..."
(without quotation marks) on the front panel of the instrument.
DISP:TEXT "WAITING..."
Single quotation marks may also be used to display the same message.
DISP:TEXT 'WAITING...'
1.6 SCPI status register
IT6700H series power records variable instrument status via three kinds of
status register, the three kinds of registers are standard event register, query
status register and status bytes register. Status byte register records the
information of other status registers.
The below picture will give you more detailed information: