ademiX P18/24-AS/1 P24/28-AS/1 en Operating instructions...
Page 2
Operating instructions Decommissioning...... 11 Temporarily decommissioning Contents the product........11 Permanently decommissioning Safety ..........3 the product........11 Intended use ........3 Restarting ........11 Qualification ........3 Recycling and disposal..... 12 General safety information..... 3 Guarantee and customer Notes on the documentation ..6 service ........
Page 3
1 Safety experience and knowledge if they have been given supervi- 1.1 Intended use sion or instruction concerning The product is intended as a use of the product in a safe way heat generator for sealed heat- and understand the hazards in- ing installations and for do- volved.
Page 4
– The product itself bells, telephones or other – to the gas, supply air, water communication systems in the building. and electricity supply lines – to the entire flue system ▶ Close the emergency control – to the entire condensate dis- valve or the main isolator.
Page 5
▶ Only fill the heating installa- tion with suitable heating wa- ter and, in cases of doubt, ask a competent person about this. 8000015138_00 Operating instructions...
Page 6
Store these instructions and all other applicable documents for further use. These instructions apply for the following products only: Product article number Display Reset button ademiX P18/24-AS/1 (H-UA) 8000015116 rotary knob button rotary knob ademiX P24/28-AS/1 (H-UA) 8000015117 3.2.1 Description of the display...
Page 7
3.3 Data plate Symbol Meaning Heating mode The data plate is mounted on the side of the product at the factory. – Permanently on: Heating mode activated The data plate keeps record of the country – Flashing: Burner on in in which the product is to be installed.
Page 8
4 Function 4.4 Checking the heating system pressure 4.1 Operating levels Once a month, check that the pres- The product has two operating levels. sure in the central heating sys- – The end user level contains information tem, which is displayed on the user interface, is between 0.05 MPa and and setting options that you require as 0.27 MPa (0.5 bar and 2.7 bar).
Page 9
▶ Set the required heating flow temperat- Note ure on the control (→ Control operating The competent person is respons- instructions). ible for filling the heating installa- tion the first time, any subsequent 4.8 Setting the domestic hot water top-ups and the water quality. temperature The end user alone is respons- Condition: No control connected...
Page 10
5.3 Guaranteeing the filling pressure of the heating installation 5.3.1 Checking the filling pressure of the heating installation In the basic display, press three times. ◁ The display shows the current Turn the filling tap (1) on slowly, fill filling pressure value. with water until the required system ◁...
Page 11
5.4 Checking the condensate Eliminating faults (→ Page 13) ▶ If you have been unable to eliminate discharge pipe and tundish the fault using the specified measures, The condensate discharge pipe and tun- consult a competent person. dish must always be penetrable. ▶...
Page 12
9 Recycling and disposal 10 Guarantee and customer service Disposing of the packaging ▶ The competent person who installed 10.1 Guarantee your product is responsible for the dis- Інформацію щодо гарантії виробника ви posal of the packaging. можете отримати, звернувшись за кон- Disposing of the product тактною...
Page 13
Appendix A Eliminating faults Code/meaning Possible cause Measure F.28 After three unsuc- Check whether the gas stopcock is open. cessful ignition at- Ignition unsuccessful Eliminate faults in the product. tempts, the product If you are unable to eliminate the ignition has switched to fault fault, contact a competent person.