Battery Settings - Dell POWERVAULT MD3620I Owner's Manual

Storage arrays
Hide thumbs Also See for POWERVAULT MD3620I:
Table of Contents

Advertisement

Replacing an SNMP address—Select the SNMP address in the
Configured SNMP addresses area, type the replacement community
name in Community name and the trap destination in Trap
destination, and click Replace.
Deleting an SNMP address—Select the SNMP address in the
Configured SNMP addresses area, and click Delete.
Validating an SNMP address—Select the SNMP address in the
Configured SNMP addresses area, and click Test. A test message is
sent to the SNMP address. A message box with the results of the
validation and any error information is displayed.
4 Click OK.
An alert icon is displayed next to each node in the Tree view for which an
alert is set.
Follow these guideline for SNMP alerts:
Any SNMP addresses that you had previously configured are displayed in
the Configured SNMP addresses area.
The SNMP Community Name is determined by the system administrator
and configured within the management application, such as the Dell
Management Console. More information about the Dell Management
Console is available at dell.com.
You can configure multiple SNMP addresses before you click OK.

Battery Settings

A smart battery backup unit (BBU) can perform a learn cycle. The smart BBU
module includes the battery, a battery gas gauge, and a battery charger. The
learn cycle calibrates the smart battery gas gauge so that it provides a
measurement of the charge of the battery module. A learn cycle can only start
when the battery is fully charged.
The learn cycle completes the following operations:
Discharges the battery to a predetermined threshold
Charges the battery back to full capacity
Configuration: About Your Storage Array
83

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3600i

Table of Contents