Download Print this page

ADF Web HD67F19-B2 Series Instruction Manual

Can / lorawan gateway - converter

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.000
English
CAN / LoRaWAN Gateway - Converter
(Order Code: HD67F19-B2-xxxMHz)
For Website information:
www.adfweb.com?Product=HD67F19-B2
For Price information:
www.adfweb.com?Price=HD67F19-B2-xxxMHz
Benefits and Main Features:
Power Supply 12...35V DC and 8...24 V AC
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual CAN / LoRaWAN Gateway
Document code: MN67F19_ENG
Revision 1.000
For others LoRaWAN products, see also the following links:
Converter LoRaWAN to
www.adfweb.com?Product=HD67F01
www.adfweb.com?Product=HD67F02
www.adfweb.com?Product=HD67F03
www.adfweb.com?Product=HD67F04
www.adfweb.com?Product=HD67F05
www.adfweb.com?Product=HD67F15
www.adfweb.com?Product=HD67F16
www.adfweb.com?Product=HD67F17
www.adfweb.com?Product=HD67F18
www.adfweb.com?Product=HD67F20
www.adfweb.com?Product=HD67F21
www.adfweb.com?Product=HD67F22
www.adfweb.com?Product=HD67F23
www.adfweb.com?Product=HD67F24
www.adfweb.com?Product=HD67F25
www.adfweb.com?Product=HD67F26
www.adfweb.com?Product=HD67F27
www.adfweb.com?Product=HD67F28
www.adfweb.com?Product=HD67F29
www.adfweb.com?Product=HD67F30
www.adfweb.com?Product=HD67F31
www.adfweb.com?Product=HD67F32
www.adfweb.com?Product=HD67F33
www.adfweb.com?Product=HD67F34
www.adfweb.com?Product=HD67F35
www.adfweb.com?Product=HD67F36
www.adfweb.com?Product=HD67F37
www.adfweb.com?Product=HD67F38
www.adfweb.com?Product=HD67F39
www.adfweb.com?Product=HD67F40
www.adfweb.com?Product=HD67F41
Page 1 of 33
(Modbus Master)
(Modbus Slave)
(Modbus TCP Master)
(Modbus TCP Slave)
(Serial)
(M-Bus)
(BACnet Master)
(BACnet Slave)
(Ethernet)
(CANopen)
(DeviceNet Master)
(DeviceNet Slave)
(DMX)
(EtherNet/IP Master)
(EtherNet/IP Slave)
(J1939)
(KNX)
(NMEA 0183)
(NMEA 2000)
(PROFIBUS Master)
(PROFIBUS Slave)
(PROFINET Master)
(PROFINET Slave)
(IEC61850 Client)
(IEC61850 Server)
(MQTT)
(OPC UA Client)
(OPC UA Server)
(S7comm)
(SNMP Manager)
(SNMP Agent)

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67F19-B2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADF Web HD67F19-B2 Series

  • Page 1 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 1 of 33 Industrial Electronic Devices User Manual Revision 1.000 English CAN / LoRaWAN Gateway - Converter (Order Code: HD67F19-B2-xxxMHz) For others LoRaWAN products, see also the following links: For Website information: www.adfweb.com?Product=HD67F19-B2 Converter LoRaWAN to...
  • Page 2 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 2 of 33 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you that Page you need to check that the following document is: INDEX UPDATED DOCUMENTATION Updated...
  • Page 3 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 3 of 33 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 4 of 33 Industrial Electronic Devices EXAMPLE OF CONNECTION: ADFweb.com S.r.l.
  • Page 5 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 5 of 33 Industrial Electronic Devices CONNECTION SCHEME: Figure 1: Connection scheme for HD67F19-B2-xxxMHz ADFweb.com S.r.l.
  • Page 6 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 6 of 33 Industrial Electronic Devices CHARACTERISTICS: The HD67F19-B2 is a CAN / LoRaWAN Gateway. It allows the following characteristics: Electrical isolation between LoRaWAN and Power Supply; Mountable on 35mm Rail DIN; Wide power supply input range: 12…35V DC and 8…24V AC;...
  • Page 7 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 7 of 33 Industrial Electronic Devices POWER SUPPLY: The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax...
  • Page 8 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 8 of 33 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 9 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 9 of 33 Industrial Electronic Devices LEDS: The device has got five LEDs that are used to give information of the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode Blinks quickly: Boot state...
  • Page 10 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 10 of 33 Industrial Electronic Devices CAN: For terminating the CAN line with a 120Ω resistor it is necessary that the ‘Dip-Switch B’ is at ON position. Cable characteristics: DC parameter: Impedance Ohm/m...
  • Page 11 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 11 of 33 Industrial Electronic Devices LORAWAN: The LoRaWAN® specification is a Low Power, Wide Area (LPWA) networking protocol designed to wirelessly connect battery operated ‘things’ to the internet in regional, national or global networks, and targets key Internet of Things (IoT) requirements such as bi-directional communication, end-to-end security, mobility and localization services.
  • Page 12 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 12 of 33 Industrial Electronic Devices ETHERNET: The Ethernet port is used for programming the device. The Ethernet connection must be made using Connector3 of HD67F19-B2 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m.
  • Page 13 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 13 of 33 Industrial Electronic Devices USE OF COMPOSITOR SW67F19: To configure the Converter, use the available software that runs with Windows called SW67F19. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 14 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 14 of 33 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a Programmable “CAN / LoRaWAN Gateway - Converter”...
  • Page 15 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 15 of 33 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 16 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 16 of 33 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 17 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 17 of 33 Industrial Electronic Devices SET COMMUNICATION: By Pressing the “Set Communication” button from the main window for SW67F19 (Fig. 2) the window “Set Communication” appears (Fig. 3). The window is divided in different sections in order to define the different parameters of the converter: Ethernet Connection...
  • Page 18 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 18 of 33 Industrial Electronic Devices THERNET ONNECTION The means of the fields for “Ethernet Connection” are: In the field “Device Name (Hostname)” the Hostname to assign to the converter is defined;...
  • Page 19 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 19 of 33 Industrial Electronic Devices CAN: The means of the field for the “CAN” section are: In the field “Baudrate” the baudrate of the CAN is defined. Figure 3d: “Set Communication ...
  • Page 20 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 20 of 33 Industrial Electronic Devices LORAWAN ACCESS: By Pressing the “LoRaWAN Access” button from the main window for SW67F19 (Fig. 2) the window “LoRaWAN Gateway Set Access” appears (Fig.
  • Page 21 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 21 of 33 Industrial Electronic Devices In the “LoRaWAN Gateway Devices List”, the list of LoraWAN end devices to connect is defined. The means of the fields for configuration are: If the field “Enable”...
  • Page 22 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 22 of 33 Industrial Electronic Devices In the “LoRaWAN Gateway Device Rules List”, the list of rules to get LoraWAN data from selected end device is defined. The table is splitted in two: “Uplink Rules”...
  • Page 23 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 23 of 33 Industrial Electronic Devices Figure 4c: “Downlink Rules” table The means of the fields in the window “Uplink Rules” are the following: If the field “Enable” is checked, the LoRaWAN rule is enabled; In the field “Port”...
  • Page 24 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 24 of 33 Industrial Electronic Devices RECEIVE FRAMES: By pressing the “Receive Frames” button from the main window for SW67F19 (Fig. 2) the “Receive CAN Frames” window appears (Fig. 5). The COB inserted in this table contains the Output data of LoRaWAN.
  • Page 25 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 25 of 33 Industrial Electronic Devices In the field “Byte6” insert the byte of the internal array where saving 6th byte of the CAN message; In the field “Byte7” insert the byte of the internal array where saving 7th byte of the CAN message; In the field “Byte8”...
  • Page 26 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 26 of 33 Industrial Electronic Devices SEND FRAMES: By pressing the “Send Frames” button from the main window for SW67F19 (Fig. 2) the “Send CAN frames” window appears (Fig. 6). The COB inserted in this table contains the data received from LoRaWAN side.
  • Page 27 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 27 of 33 Industrial Electronic Devices In the field “Byte4” insert the byte of the internal array where taking 4th byte of the CAN message; In the field “Byte5” insert the byte of the internal array where taking 5th byte of the CAN message; In the field “Byte6”...
  • Page 28 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 28 of 33 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 29 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 29 of 33 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67F19 device. Warning: If Fig.
  • Page 30 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 30 of 33 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 9: Mechanical dimensions scheme for HD67F19-B2-xxxMHz ADFweb.com S.r.l.
  • Page 31 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 31 of 33 Industrial Electronic Devices ORDERING INFORMATIONS: The ordering part number is formed by a valid combination of the following: HD67F19 - B 2 - xxxMHz Frequency for LoRaWAN communication 868: 868 MHz 915: 915 MHz Connectors Type...
  • Page 32 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 32 of 33 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 33 User Manual CAN / LoRaWAN Gateway Document code: MN67F19_ENG Revision 1.000 Page 33 of 33 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67f19-b2-868mhzHd67f19-b2-915mhz