Download Print this page
Keysight Technologies 16089A Operation And Service Manual
Keysight Technologies 16089A Operation And Service Manual

Keysight Technologies 16089A Operation And Service Manual

Kelvin/alligator clip leads
Hide thumbs Also See for 16089A:

Advertisement

Quick Links

www.valuetronics.com
Keysight 16089A, B, C, D
Kelvin/Alligator Clip Leads
Operation and
Service Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the 16089A and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight Technologies 16089A

  • Page 1 Keysight 16089A, B, C, D Kelvin/Alligator Clip Leads Operation and Service Manual www.valuetronics.com...
  • Page 2 Notices Manual Part Number Restricted Rights Legend 16089- 90030 If software is for use in the © Keysight Technologies 1991- 2015 performance of a U.S. Government Ed ition prime contract or subcontract, No part of this manual may be Software is del ivered and l icensed as...
  • Page 3 To avoid the danger of introducing additional hazards, do not install substitute parts or perform unauthorized modifications to the instrument. Return the instrument to a Keysight Technologies Sales and Service Office for service and repair to ensure that safety features are maintained in operational condition.
  • Page 4 Certification Keysight Technologies certifies that this product met its published specifications at the time of shipment from the factory. Keysight Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institution’s calibration facility, or to the calibration facilities of other...
  • Page 5 No other warranty is expressed or implied. Keysight Technologies specifically disclaims the implied warranties of merchantability and fitness for a particular purpose .
  • Page 6 Safety Symbols General definitions of safety symbols used on the instrument or in manuals. Instruction Manual symbol: the product is marked with this symbol when it is necessary for the user to refer to the instrument manual in order to protect against damage to the instrument. Al ternating current.
  • Page 7 www.valuetronics.com...
  • Page 8 Accessories Supplied Operating and Safety Precautions Operating Service Specifications Common Specifications for the 16089A, B, C, D Specifications for the 16089A, B, C Specifications for the 16089D Supplemental Performance Characteristics Supplemental Performance Characteristics of 16089A Supplemental Performance Characteristics of 16089B...
  • Page 9 4 ............Service Introduction Replaceable Parts 16089A Replaceable Parts 16089B Replaceable Parts 16089C Replaceable Parts 16089D Replaceable Parts www.valuetronics.com...
  • Page 10 General Information Introduction The purpose of this manual is to enable you to use your Keysight 16089A, B, C, Kelvin Clip Leads and Keysight 16089D Alligator Clip Leads efficiently and confidently. This manual contains both general and specific information. To...
  • Page 11 General Information Product Description Product Description The 16089A, B, C, D has been designed to operate specifically with the following four-terminal-pair type LCR meters and impedance analyzers. The 16089A, B, C, D make it possible to measure odd-shaped components that cannot be measured with conventional test fixtures.
  • Page 12 Operating You need to observe only normal precautions in handling and operating the 16089A, B, C, D. Do not exceed the operating input power, voltage, and current level and signal type appropriate for the instrument being used, refer to your instrument's operation manual.
  • Page 13 This section lists the complete 16089A, B, C, D specifications. These specifications are the performance standards and limits against which the 16089A, B, C, D is tested. When shipped from the factory, the 16089A, B, C, D meets the following specifications:...
  • Page 14 This section gives supplemental performance characteristics. Supplemental performance characteristics are not specifications, but are typical characteristics included as additional information for the operator. Supplemental performance characteristics are not guaranteed. Supplemental Performance Characteristics of 16089A Appl icable DUT size ≤15mm Diameter of DUT’s terminals...
  • Page 15 General Information Supplemental Performance Characteristics www.valuetronics.com...
  • Page 16 Figure 2- 2 Figure 2- 3 Figure 2- 4 Table 2- 1 Table 2- 2 , and Table 2- 3 Table 2- 4 • Inspect the exterior of the 16089A, B, C, D for any signs of damage. www.valuetronics.com...
  • Page 17 Preparation for Use Initial Inspection 16089A Figure 2-1 16089A Product Overview Table 2-1 Contents of 16089A Description Keysight Part Number Quantity Kelvin Clip Leads 16089-60001 16089-90030 Operation and Service Manual 1 Keysight internal-only part number. 2 Operation and Service Manual is not shown in Figure 2-1.
  • Page 18 Preparation for Use Initial Inspection 16089B Figure 2-2 16089B Product Overview Table 2-2 Contents of 16089B Description Keysight Part Number Quantity Kelvin Clip Leads 16089-60002 16089-90030 Operation and Service Manual 1 Keysight internal-only part number. 2 Operation and Service Manual is not shown in Figure 2-2. www.valuetronics.com...
  • Page 19 Preparation for Use Initial Inspection 16089C Figure 2-3 16089C Product Overview Table 2-3 Contents of 16089C Description Keysight Part Number Quantity Kelvin Clip Leads 16089-60003 16089-90030 Operation and Service Manual 1 Keysight internal-only part number. 2 Operation and Service Manual is not shown in Figure 2-3. www.valuetronics.com...
  • Page 20 Preparation for Use Initial Inspection 16089D Figure 2-4 16089D Product Overview Table 2-4 Contents of 16089D Description Keysight Part Number Quantity Kelvin Clip Leads 16089-60004 16089-90030 Operation and Service Manual 1 Keysight internal-only part number. 2 Operation and Service Manual is not shown in Figure 2-4. www.valuetronics.com...
  • Page 21 0°C to 55°C and relative humidity up to 95% at 40°C (non-condensing). The 16089A, B, C, D may be stored within a temperature range of -40°C to +70°C, and at a relative humidity of up to 95% at +40°C (non-condensing).
  • Page 22 Operation Introduction 16089A, B, C, D Operation and Service Manual Operation Introduction This chapter describes using the test leads and compensation techniques for these test leads. Test Leads Features 16089A, B, C Figure 3-1 16089A, B, C Test Leads Features 1.
  • Page 23 Operation Test Leads Features 16089D Figure 3-2 16089D Test Leads Features 1. Alligator Clips (red) . These are connected to the high terminal of the DUT. 2. Alligator Clips (black) . These are connected to the low terminal of the DUT. 3.
  • Page 24 Figure 3-4 Making a Short Condition for the 16089A and 16089D If the furnished short bar of 16089A or 16089D is corroded, worn or damaged, reverse the NOTE position or replace it with a new short bar. To reverse the short bar, remove the 2 screws that fixes the short bar and reverse the position.
  • Page 25 1. Set the Cable Length setting according to the LCR meter/ Impedance Analyzer operation manuals. 2. Connect the test leads of 16089A, B, C, D to the measurement instrument's UNKNOWN terminals. 3. Perform OPEN and SHORT compensation as described in the measurement instrument's operation manual.
  • Page 26 Service Introduction 16089A, B, C, D Operation and Service Manual Service Introduction This chapter gives replaceable parts information for the 16089A, 16089B, 16089C and 16089D. Replaceable Parts list the replaceable parts for the Table 4- 1 Table 4- 2 Table 4- 3 Table 4- 4 16089A, B, C, and D, respectively.
  • Page 27 Service Replaceable Parts 16089A Replaceable Parts Table 4-1 16089A Replaceable Parts Keysight Part Number Quantity Description 16089-60001 Test Leads 16089-04001 Cover Top 0515-0914 Screw Flat Head M3X0.5 L6 16089-60011 Large Clip Assembly 7121-2696 Wire Marker “V” 16089-01201 Short Bar 0515-1550 Screw 1 The whole unit.
  • Page 28 Service Replaceable Parts 16089C Replaceable Parts Table 4-3 16089C Replaceable Parts Reference Keysight Part Number Quantity Description Designator* 16089-60003 Test Lead 16089-04003 Cover Top 0515-0914 Screw Flat Head M3X0.5 L6 16005-60013 Test Clip Assembly Red 16005-60015 Test Clip Assembly Black 0890-1809 2 cm Tube Heat Shrinkable Red...
  • Page 29 Service Replaceable Parts 16089D Replaceable Parts Table 4-4 16089D Replaceable Parts Keysight Part Number Quantity Description 16089-60004 Test Leads 16089-04004 Cover Top 0515-0914 Screw Flat Head M3X0.5 L6 0340-1085 Insulator Alligator Clip Red 0340-1086 Insulator Alligator Clip Black 1400-1252 Alligator Clip 7121-2696 Wire Marker “V”...
  • Page 30 This information is subject to change without notice. © Keysight Technologies 1991, 2000, 2001, 2002, 2010, 2015 Edition 6, May 2015 *16089-90030* www.keysight.com www.valuetronics.com...

This manual is also suitable for:

16089b16089c16089d16089-60001