14 Troubleshooting
In this chapter
14.1 Overview: Troubleshooting
14.2 Precautions when troubleshooting
EWAA004~008D + EWYA004~008D
Packaged air-cooled water chillers
and packaged air to water heat pumps
4P688013-1C – 2023.05
14.1
Overview: Troubleshooting .................................................................................................................................................... 199
14.2
Precautions when troubleshooting........................................................................................................................................ 199
14.3
Solving problems based on symptoms................................................................................................................................... 200
14.3.1
Symptom: The unit is NOT heating or cooling as expected .................................................................................. 200
14.3.2
Symptom: Hot water does NOT reach the desired temperature ......................................................................... 200
14.3.3
Symptom: The compressor does NOT start .......................................................................................................... 201
14.3.4
Symptom: The system is making gurgling noises after commissioning................................................................ 201
14.3.5
Symptom: The pump is blocked............................................................................................................................. 202
14.3.6
Symptom: The pump is making noise (cavitation) ................................................................................................ 203
14.3.7
Symptom: The pressure relief valve opens ........................................................................................................... 203
14.3.8
Symptom: The water pressure relief valve leaks................................................................................................... 203
14.3.9
Symptom: The space is NOT sufficiently heated at low outdoor temperatures .................................................. 204
14.3.10 Symptom: The pressure at the tapping point is temporarily unusually high ....................................................... 204
14.4
Solving problems based on error codes................................................................................................................................. 204
14.4.1
To display the help text in case of a malfunction.................................................................................................. 205
14.4.2
Error codes of the unit ........................................................................................................................................... 205
This chapter describes what you have to do in case of problems.
It contains information about:
Solving problems based on symptoms
Solving problems based on error codes
Before troubleshooting
Carry out a thorough visual inspection of the unit and look for obvious defects such
as loose connections or defective wiring.
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
WARNING
When carrying out an inspection on the switch box of the unit, ALWAYS make
sure that the unit is disconnected from the mains. Turn off the respective circuit
breaker.
When a safety device was activated, stop the unit and find out why the safety
device was activated before resetting it. NEVER shunt safety devices or change
their values to a value other than the factory default setting. If you are unable to
find the cause of the problem, call your dealer.