Download Print this page
Texecom CAPTURE PET-W Manual
Texecom CAPTURE PET-W Manual

Texecom CAPTURE PET-W Manual

G2 wireless motion detectors

Advertisement

Quick Links

CAPTURE® P15-W, Q20-W, D20-W, CQ-W,
CD-W, LR50-W, PET-W, C15-W
G2 Wireless Motion Detectors
INS879EN-11

Advertisement

loading
Need help?

Need help?

Do you have a question about the CAPTURE PET-W and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Texecom CAPTURE PET-W

  • Page 1 CAPTURE® P15-W, Q20-W, D20-W, CQ-W, CD-W, LR50-W, PET-W, C15-W G2 Wireless Motion Detectors INS879EN-11...
  • Page 2 • LR50 model added • PCR01383 changes to pet coverage patterns and compliance statement for pet. • Added Capture PET-W • PCR13083 updated battery low voltage signal • PCR01383 altered quiescent currents and added low battery statement in line with KIWA requirements.
  • Page 3 2.2 CAPTURE Q20-W ........................ 2.3 CAPTURE D20-W ........................ 2.4 CAPTURE CQ-W ........................2.5 CAPTURE CD-W ........................2.6 CAPTUTRE LR50-W ......................2.7 CAPTURE PET-W ........................ 2.8 CAPTURE C15-W ........................ 3.0 Accessories ..........................3.1 Branding ..........................3.2 Optional wall or ceiling brackets ..................
  • Page 4 1.0 Quick installation 1.1 Opening the device The devices are supplied in the unlocked position. If locked; Use a flat bladed terminal driver and turn the locking mechanism ¼ turn anti-clockwise. Slide the front down and towards you to remove. For ceiling mount devices remove the facia by turning it anti-clockwise, and then unlock as above.
  • Page 5 INS879EN-11 5/79...
  • Page 6 Ceiling facia removal INS879EN-11 6/79...
  • Page 7 INS879EN-11 7/79...
  • Page 8 1.2 Mounting & Learning Location Ensure you have the correct device for the intended application, and that it is sited correctly in the desired location. The field of view should be free from obstacles and any potential false alert causes. Devices should be mounted on stable internal surfaces and are NOT suitable for use externally.
  • Page 9 INS879EN-11 9/79...
  • Page 10 Ensure the devices field of view is not obstructed INS879EN-11 10/79...
  • Page 11 Install on a flat stable surface only INS879EN-11 11/79...
  • Page 12 Ensure surrounding structures are stable INS879EN-11 12/79...
  • Page 13 For internal use only Screws & Fixings A minimum of 2 opposing fixing holes should be used to ensure maximum stability. When corner mounting care should be taken to ensure the chassis is not twisted, if the corner is uneven then two fixings on the same side would be acceptable. Where removal from mounting detection is required you must ensure that the tamper fixing is opposite to at least one of the corner or wall fixings.
  • Page 14 Learning The device should be learned before placing in its final location. To learn the device to the system: Select an empty zone slot for the device and put the system into learn mode. To power up insert the battery. The LED will flash pink while it communicates to the receiver.
  • Page 15 Wall, ceiling & flat surface mount INS879EN-11 15/79...
  • Page 16 1.3 Mode selection G2 all models (Q20-W shown) This is the default state for optimum catch performance and false activation immunity. Switch 1 should be to the left and the lens obscuration slider should be in the down position. P15-W 15m @ 90° compliant to EN50131-2-2, INCERT and PD6662 Q20-W 20m @ 90°...
  • Page 17 Pet Mode (P15-W, Q20-W & D20-W) NON-COMPLIANT When using Pet mode, switch 1 should be to the right and the lens obscuration slider should both be placed in the UP position. P15-W 10mtr @ 90° up to 35kg pet immunity (The product is compliant with EN 50131-2-2 or EN 50131-2-4 and INCERT when in the G2 setting only.) INS879EN-11 17/79...
  • Page 18 Q20-W 12mtr @ 90° up to 20Kg pet immunity (The product is compliant with EN 50131-2-2 or EN 50131-2-4 and INCERT when in the G2 setting only.) D20-W 12mtr @ 85° up to 20Kg pet immunity (The product is compliant with EN 50131-2-2 or EN 50131-2-4 and INCERT when in the G2 setting only.) Note: Never use CloakWise with PET mode.
  • Page 19 CloakWise™ D20-W & CD-W CloakWise is a proprietary detection algorithm, unique to Texecom, that can distinguish the presence of an intruder even if the unauthorised person attempts to mask or ‘cloak’ their presence. Utilising advanced signal processing techniques to both microwave and PIR channels, the CloakWise technology can recognise cloaking attempts and detect accordingly.
  • Page 20 Low mode ceiling mount CQ-W & CD-W only Low mode lowers the sensitivity of the device and provides greater false alarm immunity. Thorough walk testing across the entire protected area should be carried out to ensure catch performance is as expected. Note: Never use CloakWise with LOW mode.
  • Page 21 CQ-W and CD-W Slider Leave in the default position INS879EN-11 21/79...
  • Page 22 Do not use LR50 Only INS879EN-11 22/79...
  • Page 23 MID MAX switch Using the MID switch selection on the device reduces the range by approximately half. LR50 Slider selection The slider should not be used on an LR50 as it removes the creep zones. If the slider position is changed, the device should be thoroughly walk tested to ensure the protected area is not compromised.
  • Page 24 INS879EN-11 24/79...
  • Page 25 Closing the device LED indications When closing the devices the LED will flash as follows:- Pink - trying to connect Green - connected Red - connection failed When the device is closed and has succesfully connected to the system it will be in walktest mode for 10 minutes.
  • Page 26 Devices are supplied with the microwave adjustment potentiometer set at the mid- point. The microwave should be adjusted according the area to be protected, and great care should be taken to ensure the microwave cannot “see” beyond protected area. LED indication of the microwave pickup allows for accurate setting of the detection area.
  • Page 27 CD-W Microwave Coverage INS879EN-11 27/79...
  • Page 28 2.0 Variants 2.1 CAPTURE P15-W INS879EN-11 28/79...
  • Page 29 INS879EN-11 29/79...
  • Page 30 G2 Coverage INS879EN-11 30/79...
  • Page 31 INS879EN-11 31/79...
  • Page 32 Pet Coverage (The product is compliant with EN 50131-2-2 or EN INS879EN-11 32/79...
  • Page 33 50131-2-4 and INCERT when in the G2 setting only) INS879EN-11 33/79...
  • Page 34 INS879EN-11 34/79...
  • Page 35 INS879EN-11 35/79...
  • Page 36 2.2 CAPTURE Q20-W INS879EN-11 36/79...
  • Page 37 INS879EN-11 37/79...
  • Page 38 G2 Coverage INS879EN-11 38/79...
  • Page 39 INS879EN-11 39/79...
  • Page 40 INS879EN-11 40/79...
  • Page 41 Pet Coverage (The product is compliant with EN 50131-2-2 or EN 50131-2-4 and INCERT when in the G2 setting only.) INS879EN-11 41/79...
  • Page 42 INS879EN-11 42/79...
  • Page 43 INS879EN-11 43/79...
  • Page 44 2.3 CAPTURE D20-W INS879EN-11 44/79...
  • Page 45 INS879EN-11 45/79...
  • Page 46 G2 coverage INS879EN-11 46/79...
  • Page 47 Pet coverage (The product is compliant with EN 50131-2-2 or EN 50131-2-4 and INCERT when in the G2 setting only.) INS879EN-11 47/79...
  • Page 48 INS879EN-11 48/79...
  • Page 49 INS879EN-11 49/79...
  • Page 50 2.4 CAPTURE CQ-W INS879EN-11 50/79...
  • Page 51 INS879EN-11 51/79...
  • Page 52 INS879EN-11 52/79...
  • Page 53 INS879EN-11 53/79...
  • Page 54 DO NOT USE 2.5 CAPTURE CD-W CAPTURE CD-W is NOT Certified by KIWA (Telefication) B.V. INS879EN-11 54/79...
  • Page 55 INS879EN-11 55/79...
  • Page 56 INS879EN-11 56/79...
  • Page 57 INS879EN-11 57/79...
  • Page 58 Microwave DO NOT USE 2.6 CAPTUTRE LR50-W INS879EN-11 58/79...
  • Page 59 INS879EN-11 59/79...
  • Page 60 2.7 CAPTURE PET-W The CAPTURE PET-W is not approved INCERT. INS879EN-11 60/79...
  • Page 61 INS879EN-11 61/79...
  • Page 62 INS879EN-11 62/79...
  • Page 63 2.8 CAPTURE C15-W INS879EN-11 63/79...
  • Page 64 INS879EN-11 64/79...
  • Page 65 3.0 Accessories 3.1 Branding Branding is available for wall mount devices from our website CLICK HERE consists of a printed insert and a clear cover which fits over the front of the device and holds the insert in place. Note: The cover should be removed before sliding the front of the device off for servicing or adjustment.
  • Page 66 INS879EN-11 66/79...
  • Page 67 INS879EN-11 67/79...
  • Page 68 INS879EN-11 68/79...
  • Page 69 INS879EN-11 69/79...
  • Page 70 3.2 Optional wall or ceiling brackets Part Numbers Pack of 10 brackets AFU-0004 (not compliant with INCERT EN50131-2-2 and EN50131-2-4) Screws & Fixings To ensure maximum stability 2 screws should be used for either mounting option. Dependent on the mounting substrate, suitable fixings may be required. The size and type will depend on the choice of fixing screw.
  • Page 71 INS879EN-11 71/79...
  • Page 72 Wall mount installation INS879EN-11 72/79...
  • Page 73 INS879EN-11 73/79...
  • Page 74 INS879EN-11 74/79...
  • Page 75 4.0 Specifications P15-W, Q20-W, D20-W, CQ-W, CD- Specifications W LR50-W EN50131-2-2 (P15-W, Q20-W, CQ-W), EN50131-2-4 (D20-W, CD-W), EN50131-1, PD6662:2017 Grade 2 Class II P15-W, Q20-W, D20-W, CQ-W, CD-W LR50-W 868.2 – 868.4MHz (GDAA-1000, GDBA-1000, GDDA-1000, GDCA-1000, GDEA-1000, GDFA-1000 Product Type & Frequency 866.2 –...
  • Page 76 Transmitter Duty Cycle <1% Max RF Power 10mW Low Voltage Signal 2.85V Operating Voltage P15-W, Q20-W, CQ-W = 18mA D20-W, Maximum Current CD-W = 38mA P15-W, Q20-W, CQ-W = 21uA Quiescent Current D20-W, CD-W = 22uA Relative Humidity 0-95% non-condensing Operating Temperature -10°C to 55°...
  • Page 77 When replacing the battery in the product, care should be taken to only use a battery with a similar or greater capacity. Note: A low battery signal can only be cleared by replacing the device's battery. 5.0 Legal information 5.1 Supplier Texecom Ltd, Haslingden, Lancashire, BB4 4PW, UK. Made in England INS879EN-11 77/79...
  • Page 78 Lifetime warranty. (excludes battery which is 24 months) As the CAPTURE P15-W, Q20-W, D20-W, CQ-W, CD-W is not a complete alarm system, but only a part thereof, Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the CAPTURE P15-W, Q20-W, D20-W, CQ-W, CD- W failed to function correctly.
  • Page 79 5.5 Battery safety Do not throw into a fire Do not charge Always observe local regulaions when disposing of a battery Detector will transmit low battery warning when battery neeeds replacing Do not heat Do not short circuit Do not dissasemble Replace with battery type CR123 INS879EN-11 79/79...