4
Memo (Timing Memory)
Mostly used when many runners reach the finish in a group and there is no time to type in the
bib of each participant who reaches the finish. The registered timing impulses (e.g. from the
photocell) are listed one after the other and the correct bib can be entered later.
• By pressing the button
you enter the memo mode.
• The memo times are marked with a small "m" and listed.
• A memo time is marked with an arrow at the end.
• This marking is assigned to the desired time using the arrow keys
• The bib can be entered for the marked time (1 to 9999) and confirmed with the button
• The time for which the bib was asigned disappears from the memo screen and it prints the
running time for this bib.
• If more memo times are shown in the display, the marker moves to the next time and the
bib can be entered as described previously.
• If there is a time left that is no longer needed, it can be deleted using the button
• Man verlässt den Memo-Modus durch drücken der Taste
• If a memo time was triggered by two participants (e.g. if they cross the photocell next to
each other), then a bib is entered after the function key
time can then be entered using the function key
It is possible at any time to exit the memo window using the button
the remaining times at a later time.
5
Disqualify
You can disqualify runners who are already in the finish (have run times). The function key
label must show: "Memo Disq Focus
the key
until the correct text appears. To disqualify a runner, proceed as follows:
• press
key
• input bib of racer that you want to disqualify
• confirm bib with key
• competitor will be removed from the rankings and marked with "d" for disqualified.
Timy3 - Stopwatch
(the label above the F0 button in the display must be <MEMO>)

". If a different text is displayed, you must press
- 6 -
(1) .... start information – start display
(2) .... bib of memo-time that is marked
(3) .... memo time (momory 1)
(4) .... Marker for memo time
(5) .... memo time (momory 2)
(6) .... memo time (momory 3)
F0 .... input of bib for marked memo time
F2 .... copy of marked memo time
F3 .... exit the memo time menu
(Ende).