3.1
Start Display (1)
Bib from 1 to 9999 can be entered in this field (1). If a new bib is entered, it must be confirmed
using the button
(green "OK" button). The start automatic is also displayed (counting up,
down or manual).
Bib not started; start automatic adjusted to count up
Bib not started; start automatic adjusted to count down
u
bib is already started
leer
bib is not started, start automatic is switched off (manual)
3.2
Finish Display (2)
Enter the racer´s bib (from 1 to 9999) before reaching the finish line. If a 0 is entered, the
display shows the time of day. The bib must be confirmed using the button
3.3
Timing List (3)
Each racer who started is displayed in chronological order with an info symbol (see below),
bib, timing channel (printout only) and time.
LZ
run time
LZM
manual stopped run time (stop impulse with key
C2-C5
timing channels from intermediate time with max. precision of 1/10000 sec.
C6-C8
timing channels from intermediate time with max. precision of 1/100 sec.
3.4
Information Character
The info character is always the first character in a line. If a runner is disqualified, his time will
be deleted from the time list and will only be marked as such on the printout.
empty
valid time
c
time cleared with
i
manual changed time
d
disqualified racer
3.5
Functions for Timing List
If you press one of the three buttons, the last time stopped
is displayed at the top position in the time list.
If you press these two buttons, the time of the runner who
started first is displayed.
If you press these two buttons, the time of the runner who
started last is displayed.
Timing list is moved up by one start number.
Timing list is moved down by one start number.
Stopwatch
-key
- 5 -