Control Set Settings - Sanyo MPX-CD163 Instruction Manual

Sanyo mpx-cd163 multiplexer: instruction manual
Table of Contents

Advertisement

Available languages

Available languages

CONTROL SET SETTINGS

(MAIN MENU)
1 LANGUAGE
*
2 CLOCK SET
*
3 DISPLAY SET
*
4 VCR SET
*
5 ALARM SET
*
6 SECURITY SET
*
7 CONTROL SET
*
8 ALARM DATA
*
(*:NEXT)
The following settings must be made if using the RS-232C connector or the RS-485 connector for serial communication between a
computer or a system controller and the multiplexer.
CONTROL SET settings
Settings for serial communication between the computer and
system controller using RS-232C connectors and RS-485
connectors.
Press the MENU button.
1
The MAIN MENU screen will be displayed.
MENU
1 LANGUAGE
2 CLOCK SET
3 DISPLAY SET
4 VCR SET
5 ALARM SET
6 SECURITY SET
7 CONTROL SET
8 ALARM DATA
Use the cursor button to select
2
"CONTROL SET" and then press
NEXT
the NEXT button.
The CONTROL SET screen will be
displayed.
(CONTROL SET)
DATA SPEED
ALARM SEND
RS232C/RS485
Use the cursor button to select
3
RS232C/RS485 "RS232C", and then
+
press the setting buttons to select
"RS232C" or "RS485"
(CONTROL SET)
DATA SPEED
ALARM SEND
RS232C/RS485
Display examples:
When RS-232C is selected
Use a commercially available RS-232C cable for the
connection between the RS-232C connectors of this unit and
a personal computer.
When RS-485 is selected
Use a modular cable or a twisted-pair cable for the
connections between the RS-485 control connectors of this
unit, the system controller and the digital video recorder.
(CONTROL SET)
DATA SPEED
19200
ALARM SEND
ON
RS232C/RS485
RS232C
CAMERA CONTROL
SANYO *
(MAIN MENU)
¤
¤
¤
¤
¤
¤
¤
¤
(*:NEXT)
19200
ON
RS232C
19200
ON
RS232C
• Set a data transfer rate for serial communication.
• Set whether alarm information will be sent or not.
• Set whether RS-485 or RS-232C will be used for
serial communication.
Make dome-type camera settings to enable power
and signal control with a RS-485 dedicated coaxial
cable.
Use the cursor button to select
4
DATA SPEED "19200", and then
+
press the setting buttons to set the
communication speed.
This sets the data communication speed
for serial communication.
Use the cursor button to select
5
ALARM SEND "ON", and then press
+
the setting buttons to select the
alarm data.
Display examples:
OFF: Alarm data is not transmitted.
ON: Alarm data is transmitted.
6
Press the MENU button.
This completes the settings.
– 72 –
(CONTROL SET)
DATA SPEED
19200
ALARM SEND
ON
RS232C/RS485
RS232C
CAMERA CONTROL
SANYO *
2400, 4800, 9600, 19200
(CONTROL SET)
DATA SPEED
19200
ALARM SEND
ON
RS232C/RS485
RS232C
CAMERA CONTROL
SANYO *
English