INTERFACE SPECIFICATIONS
Multiplexer data status command
STATUS SENSE (D7)
When this command is sent by the computer, the multiplexer
returns a 5-byte operating status code (Table 1).
RXD
D7
TXD
d1
d2
STATUS SENSE (D7) bit allocation (Table 1)
The 4th and 5th bytes are spare.
1st byte
Bit
7
Indicates LIVE
0: Live image mode
and VCR
1: VCR playback mode
6
Indicates the
000: Single-screen
main monitor
5
001: 4-screen
display using 3
4
010: Multiple-screen
bits
011: Plus screen
100: Menu selection
101: Series
111: Standby
3
Indicates the
(During single-screen)
display channels
2
0000: Channel 1
and menu
1
0001: Channel 2
numbers for each
0
0010: Channel 3
display on the
0011: Channel 4
main monitor
0100: Channel 5
using 4 bits
0101: Channel 6
0110: Channel 7
0111: Channel 8
1000: Channel 9
1001: Channel 10*
1010: Channel 11*
1011: Channel 12*
1100: Channel 13*
1101: Channel 14*
1110: Channel 15*
1111: Channel 16*
(During 4-screen)
0000: 4-screen (1, 2, 3, 4)
0001: 4-screen (5, 6, 7, 8)
0010: 4-screen (9, 10*, 11*, 12*)
0011: 4-screen (13*, 14*, 15*, 16*)
(For multiple-screen)
0000: Single-screen
1000: 9-screen
1111: 16-screen*
(For plus screen)
0000: Channel 1
0001: Channel 2
0010: Channel 3
0011: Channel 4
0100: Channel 5
0101: Channel 6
0110: Channel 7
0111: Channel 8
1000: Channel 9
1001: Channel 10*
1010: Channel 11*
1011: Channel 12*
1100: Channel 13*
1101: Channel 14*
1110: Channel 15*
1111: Channel 16*
English
d3
d4
d5
Bit details
Bit
3
Indicates the
display channels
2
and menu
1
numbers for each
0
display on the
main monitor
using 4 bits
2nd byte
Bit
7
Indicates EXIT
and ALARM
6
Indicates VIDEO
LOSS
5
Indicates
SENSOR
4
Spare
3
Indicates the
main monitor
2
display status
1
using 4 bits
0
3rd byte
Bit
7
Indicates the
currently-
6
operating spot
monitor using 2
bits
5
Spot monitor
operation
4
Spot monitor
operation
3
Indicates the
camera number
2
for currently-
1
operating spot
0
monitor using 4
bits
Indicates the spot
monitor 1 camera
number when the
main monitor is
operating
*: Command for MPX-CD163 only
– 77 –
Bit details
(For serial connection)
0000: MAIN
0001: SUB 1
0010: SUB 2
0011: SUB 3
(Menu selection)
0001: Menu 1 MAIN MENU settings
0010: Menu 2 LANGUAGE settings
0011: Menu 3 CLOCK SET settings
0100: Menu 4 DISPLAY SET settings
0101: Menu 5 VCR SET settings
0110: Menu 6 ALARM SET settings
0111: Menu 7 SECURITY SET
settings
1000: Menu 8 CONTROL SET settings
1001: Menu 9 ALARM DATA settings
Bit details
1: EXIT & ALARM ON
1: VIDEO LOSS ON
1: SENSOR ON
0
0000: Normal display
0001: Automatic switching display
0010: Zoom display
0011: Still image
0100: Zoomed still image
0101: Still image zoomed
0110: Zoom position setting
0111: Still image zoom position setting
Bit details
00: Spot monitor 1
01: Spot monitor 2
10: Spot monitor 3
11: Spot monitor 4
1: Spot monitor operating
0: Single-screen
1: Automatic switching display
0000: Channel 1
0001: Channel 2
0010: Channel 3
0011: Channel 4
0100: Channel 5
0101: Channel 6
0110: Channel 7
0111: Channel 8
1000: Channel 9
1001: Channel 10*
1010: Channel 11*
1011: Channel 12*
1100: Channel 13*
1101: Channel 14*
1110: Channel 15*
1111: Channel 16*