ALARM SET SETTINGS

ALARM SET settings
Example: To use both an external alarm and
the motion sensor to detect alarms
Press the MENU button.
1
The MAIN MENU screen will be displayed.
MENU
1 LANGUAGE
2 CLOCK SET
3 DISPLAY SET
4 VCR SET
5 ALARM SET
6 SECURITY SET
7 CONTROL SET
8 ALARM DATA
Use the cursor button to select
2
"ALARM SET" and then press the
NEXT
NEXT button.
The ALARM SET screen will be displayed.
(ALARM SET)
ALARM
ACTIVE REC.
MOTION SENSOR
VIDEO LOSS
Use the cursor button to select
3
ALARM "OFF", use the setting
buttons to select "ON", and then
press the NEXT button.
The ALARM OPERATION SET screen will
be displayed.
+
NEXT
Use the cursor buttons to select
4
ALARM "EXT. OR M.SENSOR", and
+
then press the setting buttons to
select the "EXT. AND M. SENSOR".
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
DURATION
RETRIGGER
ALARM LIST
BUZZER
ALARM DISPLAY
Display examples:
The following four alarm detection methods are available.
EXT. OR M.SENSOR:
An alarm is generated when either an external alarm or a
motion sensor alarm is detected.
EXT. AND M.SENSOR:
An alarm is generated when both an external alarm and a
motion sensor alarm is detected.
English
(MAIN MENU)
¤
¤
¤
¤
¤
¤
¤
¤
(*:NEXT)
ON
*
OFF
OFF
OFF
(*:NEXT)
10 S
OFF
ON
ON
¤
EXT.:
An alarm is only generated when an external alarm is
detected.
M.SENSOR:
An alarm is only generated when a motion sensor alarm is
detected.
Use the cursor button to select
5
DURATION "10S", and then press
+
the setting buttons to select "5".
An alarm display time of 5 seconds has
been set.
Display examples:
CC: An alarm is generated only while the alarm is actually
being detected. (Minimum duration 1 second)
NC: An alarm is generated until the alarm detection is reset.
INDIV.: This lets you set the alarm duration separately for
each camera.
Use the cursor button to select
6
RETRIGGER "OFF", and then press
+
the setting buttons to select "ON".
Display examples:
OFF: Simultaneous alarms are not detected.
ON: Simultaneous alarms are detected.
ALARM SET-1
– 61 –
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
DURATION
10 S
RETRIGGER
OFF
ALARM LIST
ON
BUZZER
ON
ALARM DISPLAY
¤
1, 2, 3, 4, 5, 10, 20 ...
(in 10-second
intervals), 180S, CC,
NC, INDIV.
(ALARM OPERATION SET)
ALARM EXT.AND M.SENSOR
DURATION
10 S
RETRIGGER
OFF
ALARM LIST
ON
BUZZER
ON
ALARM DISPLAY
¤